Electrical Specifications
Related Information
■
“Electrical Specifications” on page 18
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
Electrical Specifications
Parameter
AC Requirement
Voltage
200 VAC to 277 VAC single phase, 50 to 60 Hz
Current (per input)
16A maximum per input
Current (total)
13A maximum total for all inputs at 208 VAC
Power
2700W (Total input power is approximately equally divided among the
operating power supplies.)
Related Information
■
“Physical Specifications” on page 17
■
“Environmental Specifications” on page 18
■
“Airflow Precautions” on page 19
■
“Rack Compatibility” on page 20
■
Environmental Specifications
Parameter
Metric Operating
U.S. Operating
Temperature
5˚C to 35˚C
41˚F to 95˚F
Humidity
5% to 85% noncondensing, 27˚C maximum wet
bulb
5% to 85% noncondensing, 80˚F maximum wet
bulb
Elevation (Oracle requirement)
Maximum 3000 meters at 40˚C
Maximum 9840 feet at 104˚F
Related Information
■
“Physical Specifications” on page 17
18
Oracle Fabric Interconnect F2-12 Installation Guide • November 2016
Содержание Fabric Interconnect F2-12
Страница 1: ...Oracle Fabric Interconnect F2 12 Installation Guide Part No E74400 01 November 2016...
Страница 2: ......
Страница 8: ...8 Oracle Fabric Interconnect F2 12 Installation Guide November 2016...
Страница 10: ...10 Oracle Fabric Interconnect F2 12 Installation Guide November 2016...
Страница 22: ...22 Oracle Fabric Interconnect F2 12 Installation Guide November 2016...
Страница 88: ...88 Oracle Fabric Interconnect F2 12 Installation Guide November 2016...
Страница 118: ...118 Oracle Fabric Interconnect F2 12 Installation Guide November 2016...