7. 

Operation Modes and Display 

7.1 Operation Modes: 

 

Charge  Mode:  The  rechargeable  battery  is  charged  up  to  its 

maximum  capacity.  Accumulated  charging  capacity  is  displayed 

at mAH display mode. 

 

Discharge  Mode:  It  is  used  to  reduce  the  memory  effect.  The 

rechargeable  battery  is  discharged  to  a  preset  battery  voltage 

(0.9v). Once discharge is finished, total accumulated discharging 

capacity is displayed at mAH display mode,  showing how much 

energy is discharged from the battery, which is always referring to 

the  accumulated  discharging  capacity.  No  trickle charge current 

will be applied after discharge cycle is finished.   

 

Refresh  Mode:  The  rechargeable  battery  is  charged  and 

discharged  repeatedly  to  optimize  to  its  maximum  capacity.  Old 

rechargeable  batteries  or  rechargeable  batteries  that  have  not 

been used for a long period of time can be restored to their rated 

capacity.  Depends  on  the  selected  charge  current  and  battery 

impedance,  it  can  take  tens  hours  or  even  days  time  before 

complete. Refresh mode will make 3 complete discharge-charge 

working  cycles  before  complete.  After  discharge  cycle  is 

complete, the total discharged capacity will be displayed in mAH 

display mode. When its current working cycle is in charging state, 

the mAH display is always referring to last discharging cycle for 

its charged capacity..   

 

Test  mode:    Checks  the  present  capacity  of  a  rechargeable 

battery. The maximum capacity is determined by discharging the 

rechargeable  battery  after  it  was  fully  charged.  If  the  maximum 

capacity is much lower than the rated capacity then it may reach 

the end of its lifetime. 

 

Quick Test mode: The charger will analyze the dynamic internal 

battery  resistance  by  applying  a  load  current  and  this  current 

reading  is  referred  to  the  voltage  drop  detected  on  the  battery. 

Within 10s, the tested battery resistance will be displayed in the 

unit of milliohm. For good quality batteries, the internal resistance 

is very low: in the range of 20 ~ 80 milliohms. If battery internal 

resistance  is  over  500milliohms,  then  these  batteries  are  not 

good  for  supplying  power  to  high  current  loads,  such  as  digital 

camera etc. But they can still be used for low energy loads, such 

as clock, remote controllers etc.    Always use batteries with close 

internal resistance range when they are used in serial to achieve 

maximum battery life. Alkaline and any other 1.5v batteries can 

be tested on this charger as well. If a completely empty battery is 

to be tested, it is not possible to give any correct reading. Please 

be  noted  that  since  the  internal  battery  resistance  can  be  very 

small,  and  contact  resistance  can  be  a  major  influence  factor, 

thus same battery tested in different slot or even at the same slot 

with different contact condition, the reading can be varied for 10% 

to 20%. This is normal. 

When  a  high  impedance  battery(  e.g.  Over  2500milli  ohm)  is 

loaded onto the charger, due to its high internal impedance, real 

displayed  charging  current  can  be  much  less  than  your 

pre-selected  charging  current.  When  this  happened,  it  doesn’t 

mean  the  charger  is  defective.  Eventually  it  needs  longer 

charging time until fully charged. 

 

 

7.2  Display 

 

Charge/Discharge Current: instantaneous current is displayed. 

 

Time  Elapsed:  The  charging/discharging  time  of  the  last  cycle  is 

displayed. 

 

Accumulated  Capacity:  The  accumulated  battery  capacity  is 

displayed  in  mAh.  For  discharge  mode,  it  is  referring  to  the 

accumulated energy discharged from that battery. For refresh mode, 

previous charging capacity is displayed even when current working 

stage is at discharge cycle. 

 

Battery Voltage: The instantaneous battery voltage is displayed. 

 

At  QUICK  TEST  mode,  it  shows  the  internal  battery  resistance  in 

mili- ohm(0.001R). 

 

Full:  After  the  rechargeable  battery  is  fully  charged  in  any  of  the 

operation  modes,  trickle  charging  will  be  started  automatically. 

Trickle  charging  prevents  the  rechargeable  batteries  from  being 

overcharged and compensates for self-discharging of the batteries 

 

8. 

Maintenance 

The device is maintenance-free but should be cleaned occasionally. When 

cleaning, the device must be removed from any power source. Only use 

dry and soft cloth to clear the housing of the charger. Do not use abrasive 

or solvents. 

 

9. 

Disposal 

9.1 Disposal of waste electrical and electronic equipment 

In  order  to  preserve,  protect  and  improve  the  quality  of  environment, 

protect human health and utilize natural resources prudently and rationally, 

the  user  should  return  unserviceable  product  to  relevant  facilities  in 

accordance with statutory regulations.   

The crossed-out wheeled bin indicates the product needs to be disposed 

separately and not as municipal waste. 

Содержание BT-C700

Страница 1: ... charger has its backlight turned on after each key press Back light will be switched off after 30 seconds when no key is pressed The maximum charging capacity can be up to 20 000mAH 2 Delivery Content Battery Charger BT C700 1pcs Power Adapter 1pcs Operation Instructions 1pcs Optional accessory Part 3 Safety Instructions We do not assume liability for resulting damages to property or personal inj...

Страница 2: ...ing mode needs to be changed detach the battery from charger and insert the battery into slot again while that selected slot LCD display content is in flashing press MODE button to choose desired working mode When working mode is changed working current adjustment is possible also 5 2 Current Selection Within the first 6 seconds after inserting the battery or right after power up press the CURRENT...

Страница 3: ...ys use batteries with close internal resistance range when they are used in serial to achieve maximum battery life Alkaline and any other 1 5v batteries can be tested on this charger as well If a completely empty battery is to be tested it is not possible to give any correct reading Please be noted that since the internal battery resistance can be very small and contact resistance can be a major i...

Страница 4: ...e chemical symbols for the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batteries rechargeable batteries free of charge to any collecting point of your local authority 10 Technical Data Официальный представитель компании Opus Instruments в Казахстане Интернет магазин www kupifonar kz e mail info kupifonar kz тел 8 727 296 97 64 Operating Voltage 12V 16VDC P...

Отзывы: