CP80-4 ; CP90-4
Ref. 1887-SU-01-H
Page 40
When ‘Acquisition Mode’ is set to ‘Single Frame’ or ‘CoaxPress’, and
‘Granularity’ is ‘On’, the exposure time is set by ‘Exposure Time’. When ‘Off’,
the exposure time is the high-level duration of the external trigger signal.
Special features
ReverseY
Revert image in the vertical direction.
For example, let’s take a frame of 100 lines height and beginning at vertical
offset of 100.
When ReverseY=No, you will get the lines in that order: 100,101,102,...,199
When ReverseY=Yes, you will get the lines in that order: 1619,1618,...,1518 : in
that case, you will get a vertically mirrored ROI.
IndicatorLamps
Switch ON/OFF indicator lamps.
ColorSensor
Has camera a color sensor.
Return 1 for a color sensor and 0 for a monochrom sensor
DualROIMode
Dual ROI allows to define two not-overlapping ROIs (Region Of Interest).
The option is selected by writing
‘On’ to that entry.
ROI1 is always the top ROI and ROI2 the bottom ROI.
By default, vertical offset of ROI1 is 0 and vertical offset of ROI2 is equal to the
height of ROI1.
Streaming has to be stopped before changing the 'DualROIMode' register.
Vertical offsets and heights of the 2 ROIs are defined in the entries
‘ROI1_OffsetY’ a,d ‘ROI2_OffsetY’.
Width of ROIs are the same and can be defined in the
entry ‘Width’.
Horizontal offset of ROIs are the same and can be defined in the entry
‘OffsetX’.
When
‘DualROIMode’ is ‘On’, the entry ‘Height’ is reserved and is automatically
calculated by the camera.