CP90-25P-M/C-72
Ref. 1896-SU-01-D
Page 11
SyncOut has a built in 50 Ohm driver.
At 50 Ohm termination, the driver voltage is in between 0 (low level) to
~2 Volts (high level). At high impedance termination, the driver voltage is
in between 0 (low level) to ~4 Volts (high level).
SyncOut voltage limit ranges from 0 Volt to + 5 Volts. Voltages applied
beyond these limits may damage the SyncOut Output.
The Auxiliary connector may also be used to update the firmware of the
camera. Please use the USB2 programming adapter cable.