CamPerform CP80-3-M/C-540
Ref. 1888-SU-01-C
Page 35
ExposureTime
Sets the Exposure time (in microseconds) when ExposureMode is Timed
Minimum : 98
Increment : 1
Maximum : ExposureTimeMax
Address : 0x6010 (for integer values), 0x60C8 (for floating values)
Length : 4
Access : RW
ExposureTimeMax
Maximum Exposure time (in microseconds) when ExposureMode is Timed
Address : : 0x60BC (for integer values), 0x60CC (for floating values)
Length : 4
Access : RO
GranularityMode
Write 0x01 to activate Granularity mode. In that mode, exposure time is set by
register (ExposureTime) when using external triggering or trigger over
CoaxPress
Write 0x00 to disactivate Granularity mode
Address : 0x6018
Length : 4
Mask : 0x0000FF00
Access : RW
IndicatorLamps
Switch ON/OFF indicator lamps.
Write 0x00 to switch ON the indicator lamps.
Write 0x01 to switch OFF the indicator lamps.
Address : 0x601C
Length : 4
Mask : 0x00FF0000
Access : RW
Содержание CamPerform C-540
Страница 1: ...CamPerform CP80 3 M C 540 CoaxPress Camera User Manual Ref 1888 SU 01 C...
Страница 2: ......
Страница 4: ...CamPerform CP80 3 M C 540 Ref 1888 SU 01 C Page 2 Gen i Cam 36...
Страница 23: ...CamPerform CP80 3 M C 540 Ref 1888 SU 01 C Page 21 Mechanical Dimensions F Mount Lens CM...
Страница 32: ...CamPerform CP80 3 M C 540 Ref 1888 SU 01 C Page 30 6 Click on Exit 7 Switch OFF camera and switch ON camera...