OPTOTRONIX AURORA LCU EV2O Скачать руководство пользователя страница 11

11 

 

Battery

 

Test

 

The

 

battery

 

test

 

function

 

of

 

the

 

AURORA

 

LCU

 

EV

2

O

 

can

 

be

 

started

 

at

 

any

 

time

 

by

 

short

 

pressing

 

the

 

“Set”

 

button,

 

during

 

the

 

battery

 

test

 

(about

 

3

 

seconds)

 

the

 

connected

 

LEDs

 

are

 

disabled!

 

 

At

 

first,

 

2

 

of

 

the

 

blue

 

status

LEDs

 

are

 

blinking

 

up,

 

showing

 

which

 

battery

 

type

 

is

 

programmed

 

(Lipo,

 

LiFe,

 

or

 

BEC).

 

The

 

voltage

 

level

 

of

 

the

 

battery

 

can

 

be

 

read

 

with

 

the

 

6

 

blue

 

status

LEDs

 

of

 

the

 

AURORA

 

LCU

 

EV

2

O

.

 

If

 

4

 

LEDs

 

are

 

active,

 

the

 

battery

 

state

 

of

 

charge

 

is

 

60

75%.

 

If

 

no

 

LED

 

is

 

active

 

any

 

more,

 

the

 

battery

 

should

 

be

 

disconnected

 

and

 

recharged.

 

 
 
 
 
 
 
 
 
 

If

 

the

 

programmed

 

battery

 

voltage

 

becomes

 

critical,

 

the

 

AURORA

 

LCU

 

EV

2

O

 

completely

 

shuts

 

down

 

after

 

a

 

fast

 

flashing

sequence

 

of

 

the

 

green

 

Mode

 

LED

 

to

 

protect

 

the

 

battery.

 

It

 

can

 

only

 

be

 

restarted

 

by

 

reconnecting

 

the

 

battery.

 

 
 

Stand

 

Alone

 

Mode

 

This

 

“autonomous

 

operation

 

mode”

 

mode

 

allows

 

to

 

operate

 

the

 

model

 

lighting,

 

even

 

if

 

the

 

receiving

 

system

 

is

 

not

 

active

 

(e.g.

 

exhibitions

 

or

 

showroom),

 

or

 

may

 

not

 

be

 

switched

 

on

 

(e.g.

 

Building

 

competition).

 

 

Activate

 

all

 

light

 

outputs

 

which

 

should

 

be

 

active

 

and

 

then

 

push

 

the

 

button

 

for

 

at

 

least

 

2

 

seconds.

 

The

 

2

second

long

push

 

always

 

will

 

be

 

confirmed

 

by

 

flashing

 

the

 

green

 

Mode

 

LED

 

three

 

times.

 

The

 

blue

 

Signal

 

LED

 

now

 

starts

 

to

 

blink,

 

the

 

Stand

 

Alone

 

mode

 

is

 

active

 

and

 

the

 

electronic

 

is

 

no

 

longer

 

controlled

 

by

 

the

 

receiver

 

signal!

 

Exit

 

the

 

Stand

 

Alone

 

mode

 

by

 

pushing

 

the

 

button

 

2

 

seconds

 

again.

 

 

Programming

 

Mode

 

Connect

 

the

 

power

 

supply

 

and

 

receiver

 

signal

 

(or

 

a

 

servo

 

tester)

 

to

 

the

 

AURORA

 

LCU

 

EV

2

O

.

  

Hold

 

the

 

button

 

permanently

 

pushed

 

before

 

the

 

startup

 

sequence

 

is

 

completed.

 

If

 

the

 

programming

 

mode

 

has

 

been

 

successfully

 

started,

 

all

 

blue

 

status

LEDs

 

are

 

flashing

 

very

 

quickly

 

for

 

4

 

seconds.

 

Release

 

the

 

button

 

as

 

soon

 

as

 

the

 

flashing

 

starts.

  

Now

 

you

 

entered

 

the

 

Programming

 

Mode.

 

 
 
 
 
 
 
 

>90%

 

15%

 

30%

 

45%

 

60%

 

75%

 

Содержание AURORA LCU EV2O

Страница 1: ...AURORA LCU EVO FINEST SCALE LIGHTING TECHNICS 2 L I G H T C O N T R O L U N I T MANUAL Download latest at Version www Optotronix de FINEST SCALE LIGHTING TECHNICS Exclusive Dealer...

Страница 2: ...es These are the features of the AURORA LCU EV2O 6 outputs Permanent Flash Beacon Afterburner Multi Gun 8 different flash sequences 3 different chose able points of time 4 beacon sequences imitation o...

Страница 3: ...osition Flash Landing Light Landing Light Runway Light 3point Switch for OFF Position Flash Runway Light Mixer to flaps Light Outputs 6x Top MINUS Bottom PLUS PLUS wires can be put together Status LED...

Страница 4: ...U EV2O is BEC Supply that means the supply is NOT protected for low voltage If the programmed battery voltage becomes critical the AURORA LCU EV2O shuts down after a fast flashing sequence of the gree...

Страница 5: ...ode As soon a valid signal is present again the AURORA LCU EV2O wakes up FailSafe Emergeny Lighting A very important and useful function is the indication of signal disruptions during the flight live...

Страница 6: ...s the polarity of the SEOUL 1Watt 3Watt power LEDs Next to each pole is a small brass stub which is scored on the minus side but not on the plus side The classic 3mm 5mm LED types mark the plus termin...

Страница 7: ...parallel to one output Only connect LEDs to the AURORA LCU EV2O if all outputs are finally programmed So it is avoided that LEDs that are configured for flash operation burn because they are connected...

Страница 8: ...ginal afterburner effects A very special feature by Optotronix is the afterburner random generator which generates a very realistic flame effect In contrast to low cost lighting electronics there is n...

Страница 9: ...up to a total current of 5A When programming the Multi Gun Light Effect consider the following the Activation Point of the Effect has to be the highest programmed one even higher as the landing light...

Страница 10: ...thing above that voltage has to be converted into heat in the series resistor That is why the operation at 3 6V 4 8V 3s 4s NiMh or 3 7V 1s Lipo has to be preferred Operating the AURORA LCU EV2O Startu...

Страница 11: ...s autonomous operation mode mode allows to operate the model lighting even if the receiving system is not active e g exhibitions or showroom or may not be switched on e g Building competition Activate...

Страница 12: ...he AURORA LCU EV2O If the programminf step for battery type shall NOT be executed changed you can skip this step by doing nothing for 5sec Programming the Light Outputs The first blue status LED light...

Страница 13: ...Special Flash 25 Special Flash Beacon Effects 26 Beacon fast 27 Beacon medium 28 Beacon slow 29 Beacon 40 dimmed Double Flash 30 Soft Start Permanent Light Slowly dimming up of permanent lights Nachb...

Страница 14: ...atically Programmed flash sequences and activation points are only stored if the programming mode was executed completely Overview of the Programming Steps Here you see an overview of the programming...

Страница 15: ...uences This is an overview of the sequences of the green Mode LED Operating Mode Programming Mode Permanent ON Operation Mode State of Charge 30 Ready Slow Blinking ON OFF State of Charge 30 3x short...

Страница 16: ...EV2O we assume no liability Further claims are excluded The product is used only for model aircrafts The AURORA LCU EV2O has been suppressed by constructive measures Negative influences on the quality...

Отзывы: