OTS Series Command Line Interface User Guide
Page 13 of 95
2.2.4
INBAND Interface Configuration
INBAND Interface Configuration map
Feature
Value
Default
User level
Save to flush
Admin
Enabled/Disabled
Enabled
adpro
Yes
Name
String of 0~64
NULL
adpro
Yes
2.3
Parameter Setting Procedure
Parameters can be set by connecting a computer to the console port or by way of TELNET. Setting parameters using
TELNET is possible only when the Management Port of the OTS system is connected to the LAN and the IP address is
set. The procedure for setting parameters is shown below.
•
Prepare and connect a computer either through the console port of the OTS system or through TELNET.
•
Connecting through the console port or through TELNET, a command line prompt should appear with the information
of the OTS system and ask for a username and password.
•
Enter a valid username and password to gain access to the OTS system.
•
Set and parameters or configurations once logged into the system with the correct credentials.
•
Save newly set parameters using write command on the main menu.
•
Disconnect the connection between the computer and the OTS system to end parameter configuration.
2.3.1
Preparing the Parameter Setting Terminal
The communication conditions necessary for the OTS system parameter setting terminal are shown in 2.3.2 below.
2.3.2
Parameter Setting Terminal Conditions and Communication Conditions
(1)
Parameter setting terminal conditions
No.
Item
Specifications
1
Terminal setting
ANSI X3.64/VT100
(2)
Communication conditions
No.
Item
Specifications
1
Screen size
80 columns
×
24 lines/screen or more
2
Character
8 bits/character