Delta Elec. Inc.
DP-3638/DP-7606
Company Confidential Optoma ______________________ Delta____________
27
2010/01/04
Yes
No
Waiting
Power On
< DMD error >
Power: Flashing Red
Light 8
Temp: OFF
Lamp: OFF
Yes
• DMD chip error.
• Check DMD Board PWB Ass’y .
No
• Lamp Cover A’ssy is not attached
• Connector (
P802
) on Main Board disconnected.
or
• Thermal break sensor is open.
• Connector (
P803
) on Main Board disconnected.
< System error >
Power: Flashing Red
Light 4 or 7
Temp: OFF
Lamp: OFF