Confidential
4-4
EW536/HD66/DW318
4-6 PC MODE
Note: - When getting into function test, adjust the zoom ring and focus ring
to guarantee the image maximum and clearest, then start to test.
- Test signal: analog 1280 x 800 @60Hz
- We take EW536 for example here.
- Connect VGA IN port of Projector with VGA port of Chroma
and connect VGA Out port of Projector with VGA port of Monitor
by VGA cable, check if the Projected image and the LCD
image are the same.
1. Frequency and tracking boundary
Procedure
- Test equipment: video generator
- Test signal: analog 1280 x 800 @60Hz
- Test pattern: general-1 or master
- Check and see if the image sharpness is well
performed.
- If not, re-adjust by the following steps:
(1) Select "Frequency" function to adjust the total
pixel number of pixel clock in one line period.
(2) Select "Tracking" function and use right or left
arrow key to adjust the value to minimize video
flicker.
- Adjust Resync or Frequency/Tracking/H Image
Shift/V Image Shift to the inner screen.
Inspection item
- Eliminate visual wavy noise by Rsync, Frequency
or Tracking selection.
- Check if there is noise on the screen.
- Horizontal and vertical position of the video should
be adjustable to the screen frame.
Criteria
- If there is noise on the screen, the product is
considered as failure product.
- If there is noise on the screen, use auto or manual
“frequency” function or “tracking” function to adjust
the screen.
- The PC mode functionally sure be workable
include support format with frequency and auto
detected functional will be workable.
General-1
Master
Содержание DW318
Страница 65: ...EW536 HD66 DW318 Confidential III ASSY TOP COVER MODULE 2 15 3 1 10 9 8 7 6 5 4 11 12 13 14 ...
Страница 68: ...EW536 HD66 DW318 Confidential VI ASSY BOTTOM COVER MODULE ...
Страница 70: ...VIII Confidential EW536 HD66 DW318 ASSY ENGINE MODULE ...
Страница 73: ...Confidential XI EW536 HD66 DW318 1 2 3 4 5 6 7 8 9 10 11 12 13 13 A K ...