English
4
Entering UST mode for installation setup
To complete the UST lens setup, follow the steps below.
1.
Use the hot keys “Exit, Input, Left, Right” on the keypad or Remote control to do UST lens calibration.
2.
After UST lens calibration, press “Exit“ to turn off the projector.
3. Disconnect the AC cable.
Boresight pre-adjustment
The UST lens boresight module needs to be adjusted before fitting to the projector.
1.
Make sure the boresight gears are in the initial state. If not, turn the small boresight gears counter-
clockwise to the end position, where 2 marks are roughly aligned.
2. Turn the boresight gears clockwise according to the installation orientation.
Notee:
The ZU850 has a different orientation table from ZU660 and ZU1050.
A
B
C
ZU850
Orientation
A
B
C
Table top
3+1/4
9
9
Portrait (L)
6 + 3/4
7
10+3/4
Portrait (R)
5 + 1/4
10 + 3/4
6
Ceiling mount
10 + 2/4
7 + 1/4
7 + 1/4
Upright
10 + 3/4
8 + 1/4
8 + 2/4
ZU1050 / ZU660 / ZU750 / ZU860
Orientation
A
B
C
Table top
3+1/4
7 + 2/4
8 + 2/4
Portrait (L)
5+1/4
4
10
Portrait (R)
5 + 1/4
9 + 2/4
4 + 2/4
Ceiling mount
7 + 1/4
6
6
Upright
7 + 2/4
7
7 + 1/4