Optocore DD8RP Скачать руководство пользователя страница 3

 

 

DD8RP

 

 

3 / 15 

rev. 1.0

 

 

Purchaser Information 

 

Operating Manual 

Please read this manual – if you call for technical support, we’ll assume that you have. Study the 
operating manual carefully in order to familiarize yourself with the device and its operation. It contains 
numerous information and hints for the proper use of the device. 

It cannot be excluded that this operation manual shows typographical mistakes or misprints; it is 
however regularly revised. 

Modifications, which serve the purpose of technical improvement of the device, may be carried out 
without prior notification

.

 

 

Transport and Shipping 

Always ensure the careful handling of the device. If possible transport or shipping should always 
occur in special, shock-absorbing transport cases. If these are not available we recommend well-
upholstered packaging such as the coated carton in which the device was delivered. 

We strongly advise not to use simple flight-cases without rack-in-rack mounting. 

 

Environments 

This device can be used in E1, E2, E3, E4, or E5 environments (as listed below) according to the 
harmonized European standards EN55103-1 and EN55103-2 “Electromagnetic compatibility – 
Product family standard for audio, video and audio-visual and entertainment lighting control apparatus 
for professional use” 

E1-Residental 

E2-Commercial and light industrial 

E3-Urban outdoors 

E4-Controlled EMC environment e.g. broadcast and TV-studio 

E5-Heavy industry 

The product is intended for the use in moderate climate. 

 

Ventilation 

Do not block or cover any ventilation slits. Install the device in accordance to the operating manual.  
Leave sufficient ventilation space around the units (at least approx. 200mm 

 7,87" free space behind 

the rear-panel) and care for free air movement near the ventilation-slits on both sides of the device. 
Keep the rear of the rack open during operation. Do not set up the device close to equipment 
producing a lot of heat, for example power-amplifiers. Leave enough space (minimum ½ RU) to any 
heat emitting device. A

 

DD8RP may be placed on top or beneath other Optocore products, except 

DD32, without additional space. 

 

Water and Moisture etc. 

To prevent fire or shock hazard do not expose device to the effects of direct sunlight, dust, water, or 
rain during operation or storage. 

 

Cleaning 

Only use a dry linen cloth to clean the device. In case of strong soiling moisten the cloth using a little 
water and a small amount of household detergent. Never use cleansing agents containing solvents to 
clean the device. 

 

Operating and Storage Temperature 

Operating temperature:  0

°

C …50

°

 34

°

F … 122

°

F; ensure proper ventilation 

Storage temperature:  -20

°

C …60

°

 -4

°

F … 140

°

Содержание DD8RP

Страница 1: ...DD8RP Operating Manual Rev 1 0 Operating Manual for OPTOCORE DD8RP REPEATER MEDIA CONVERTER MODULE Copyright 2007 All rights reserved OPTOCORE GmbH Lisbergstr 7 81249 Munich Germany ...

Страница 2: ...other way Pay special attention to plugs and sockets of the device Never switch on power amplifiers before the complete system is stable and the level meters of the OPTOCORE CONTROL software indicate a normal level Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device and a risk of injury The device can only be removed from the power...

Страница 3: ...rtainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for the use in moderate climate Ventilation Do not block or cover any ventilation slits Install the device in accordance to the operating manual Leave sufficient ventilation s...

Страница 4: ...afety This product is a Laser Class 1 product It complies with IEC 60825 1 FDA 21 CFR 1040 10 and 1040 11 Interference of external objects and or liquids with the device Never push objects of any kind into the device through openings in the casing They may come in touch with dangerous voltage points or short out parts that could result in a fire or electric shocks Never spill liquid of any kind on...

Страница 5: ...apparatus for professional use EN 55103 1 Emission EN 55103 2 Immunity The authorised declaration and compatibility certification lies with the manufacturer and can be viewed on request Responsible as manufacturer is OPTOCORE GmbH Lisbergstr 7 81249 Munich Germany Represented by Marc Brunke Managing Director N B The awarding of the CE label confirms the compliance with legal directives issued for ...

Страница 6: ... 3 CE Conformity 5 Eye Safety 5 Device Description 7 Front Panel 8 Rear Panel 8 Device Details 9 LINK Ports 9 Power Supply 9 Connectors and Cables 9 Starting Up 10 Hardware Connection 10 Connection Tables 11 Technical Specifications 12 Dimensions and Weight 13 Warranty and Liability 14 Shipping Contents 14 Company Information 15 ...

Страница 7: ... depends on the implemented optical transceiver This allows the configuration exactly appropriate for the application E g one LINK may extend the distance between two Optocore devices in an OPTOCORE OPTICAL DIGITAL NETWORK while the other LINKs are used in totally different networks with non Optocore protocols LEDs on the front give detailed information about the status and operating state of each...

Страница 8: ...operation OVP LED Indicates over voltage protection 300 VAC PWR 1 LED AC Power supply 1 is working correctly PWR 2 LED DC Power supply 2 is working correctly RS232 plug D Sub 9 RS232 connection for remote control and update via PC USB plug and LED USB connection for remote control via PC LED ON indicates USB is connected LED blinking indicates data traffic Rear Panel LINK 1 4 Independent LC type o...

Страница 9: ... or transformers The power supply unit is 400 VAC tolerant and protected against high current The OVP Over Voltage Protection LED on the front will indicate over voltage at 300 V simultaneously suppressing the normal function of the device When the OVP LED is lit immediately disconnect the device from the power line to prevent any damage to the device The power input has a fuse replaceable without...

Страница 10: ...on Port A of the LINK 1 is used as interface to the DD32E with ID 2 port B as interface to the DD32E with ID 2 Fig 1 DD8RP between two DD32E functioning as repeater in order to extend the distance of the multimode connection The second example in Fig 2 shows an application where the two DD8RP work as repeater and media converter The first DD8RP functions as a converter from multimode to monomode t...

Страница 11: ...male XLR Pin out RS232 Port RS232 Power Channel RXD TXD Internally Bridged 5VS GND Pin 3 2 1 4 6 7 8 9 5 Use 1 modem cable male female to connect to PC D Sub 9 female 5 1 9 6 Locking system acc to 4 40 UNC Pin out USB Port USB Channel VBUS D D GND Pin 1 2 3 4 USB device connector ...

Страница 12: ...00 VAC tolerant Frequency 50 60 Hz Power consumption 4 14 VA dependent of number of SFPs installed Fuse D1 0 A slow behavior glass 5 mm x 20 mm acc to UL 48 14 Inrush current limit 7 A Protection circuit 400 VAC tolerance over voltage over current and over temperature monitor Security classification Class 1 basic insulation connected to the protective grounding conductor Security regulations Harmo...

Страница 13: ...83 19 438 17 25 44 1 73 136 5 35 44 1 73 1RU Front plate Front elements Handles Add 6 0 24 Rear elements Add 15 0 6 Weight 2 0 kg 4 4 lbs Modifications that serve the purpose of technical improvement of the device may be carried out without prior notification ...

Страница 14: ...e contact your distributor dealer Our web site http www optocore com provides a complete list of Optocore distributors dealers Always ensure the careful handling of the device If possible transport or shipping should always occur in special shock absorbing transport cases If these are not available we recommend well upholstered packaging such as the coated carton in which the device was delivered ...

Страница 15: ...DD8RP 15 15 rev 1 0 Company Information Mailing Address OPTOCORE GmbH Lisbergstr 7 D 81249 Munich Germany Telephone 49 0 89 8999640 Facsimile 49 0 89 89996455 Internet www optocore com Email ...

Отзывы: