SRO70 Installation Manual 

Step 7

Connect the blue tubing from the Optimized Water Outlet on processor to downstream 

equipment. Open the feed valve and check for leaks.

v

 Place in Service

v

 Troubleshooting

Problem

Possible Cause

Resolution

Running out 

of water.

Valves in incorrect 

operating position
Operating Pressure 

reduced
Very cold Feed 

Water temperature 

Low Feed Water 

Pressure
Demand exceeds 

system capacity

Ensure the feed water valve and 

storage tank valve are open
Pre-Filters need to be replaced 

Raise water temp to increase 

production or determine if higher 

capacity system is required
Install optional Feed Water Pres-

sure Booster Pump
Determine if the demand is 

unusual or inconsistent, or resize 

system

Poor water 

quality.

Membrane failure

Replace AMS-QT10 membrane

Short AMS-

QT10 mem-

brane life.

Poor Feed Water 

quality, presence of 

iron, silica or non-

calcium carbonate 

hardness

Determine Feed Water quality by 

obtaining a water quality report 

from city water supply utility or 

contact your OptiPure dealer 

Short Pre-

Filter life

Heavy sediment 

loading

Add FXAF01-12 or -12B for 

added Pre-Filter protection

Processor 

Either Does 

Not Shut Off 

or Turn On

Auto shutoff valve 

not functioning

Replace auto shutoff valve

Optimized Water 

to Equipment

Содержание SRO70

Страница 1: ...nual Rev 2 2 SRO70_Simple_Install_v2 2 indd 2018 Procam Controls Inc All Rights Reserved Access manuals spec sheets and additional educational materials for foodservice water treatment at our website...

Страница 2: ...relative humidity 80 at 88 F 31 C 4 Installation category II 5 Pollution degree II 6 Indoor use only protect from elements Safety Instructions 1 Please read and follow these instructions when connecti...

Страница 3: ...to rain or direct sunlight Feed water connection An adequate flow and pressure of water to the unit is essential for successful operation Drain A drain should be located within 5 ft of the system Dra...

Страница 4: ...stalling keep line from the Tank to the equipment as short as possible to minimize pressure loss Avoid loops or kinks in tubing Do not cut tubing with wire crimpers or dikes IMPORTANT PROTECT PROCESSO...

Страница 5: ...rs or attach directly to studs Be sure to allow 3 clearance below cartridges for removal Step 2 Route the loose end of 1 4 black tubing from processor to a suitable drain and fasten it at the drain So...

Страница 6: ...own in this example Connect the other end to the Feed Water Inlet on processor Step 4 Install the tank valve on the top of the tank Connect a piece of 3 8 blue tubing to tank valve Connect the other e...

Страница 7: ...ntil all air is purged from system and product water becomes clear Close the feed valve Step 6 The system includes an optional auxiliary connection This connection provides equipment with water that h...

Страница 8: ...increase production or determine if higher capacity system is required Install optional Feed Water Pres sure Booster Pump Determine if the demand is unusual or inconsistent or resize system Poor water...

Отзывы: