Installation Procedure

1

.  Turn off all equipment to be fed by the OptiPure System. Locate water supply cut-off valve and turn off.

2. 

Determine if water line has an existing water treatment system. Is so, examine system for use of polyphospate or 

other scale inhibitors. ScaleX2

®

 will not be effective if used in conjunction with other scale inhibitors. Remove the 

scale inhibitors from the water line or discontinue installation.

3.  Install a 1/2” full-flow ball valve on the water supply side that will feed the water system.
4.  Anchor the OptiPure System on a wall stud or suitable mounting material spanning wall studs. 

System must be 

vertical and upright.

5.  Run a suitable line from the 1/2” full-flow ball valve at the tap water source to the inlet ball valve on the left side 

of the ScaleX2

®

 system.  Use 2-3 wraps of teflon tape and brace the inlet ball valve on the system with a wrench 

when connecting the feed water line.  NOTE:  DO NOT OVERTIGHTEN CONNECTION FITTING INTO BALL 

VALVE.

6.  Select the appropriate size tubing for the equipment being fed and connect it to the outlet of the ScaleX2

®

 

System.  NOTE: DO NOT connect the tubing to the equipment at this time. Prior to making connection to the 

equipment this line will be used to facilitate flushing the system. As an option, a drain valve in a tee on the outlet 

side of the OptiPure system could be provided in the line to facilitate flushing when changing filters. 

7.  With System inlet valve closed, slowly open the 1/2” full-flow ball valve at the tap water source.  Check for leaks.
8.   If a drain valve was not installed on the outlet side of the system, hold the tubing that will connect to equipment 

in a clean bucket or over sink or drain. Open the system inlet feed valve and allow water to flush through system 

for ten (10) minutes at the specified system flow rate to allow air and any carbon fines to escape.  NOTE:  NO 

ACTIVATION IS REQUIRED FOR THE OPTIPURE SYSTEM TO PERFORM PROPERLY. FLUSHING IS 

RECOMMENDED TO ALLOW AIR TO ESCAPE THE SYSTEM AND REMOVE ANY CARBON FINES PRIOR TO 

CONNECTING TO EQUIPMENT.

9.  Make certain that the end of the tubing to be connected to the equipment is clean and sanitized.

Model SX2-21

Capacity:  15,000 gals/56,800 L

Service Flow Rate:  1.5 gpm/5.7 lpm

Inlet/Outlet: 1/2” FNPT

•  IF water hammer is evident, install water hammer arrestors before OptiPure unit.  
•  Do NOT overtighten fitting connections into inlet valve our housing outlet.  
•  Always back-up valves and fittings with a wrench when installing a fitting to avoid turning the valve.
•    Do NOT install the unit behind equipment where it may be difficult to access the system for filter replacement.

Position the OptiPure unit in a suitable location. The direction of flow through the OptiPure unit is always left to right; 

keep this in mind when determining installation location.  Do NOT mount the OptiPure system near any source of 

heat.  Also, do not mount the system above any device or area that would be adversely affected by water. 

Model SX2-22

Capacity:  30,000 gals/113,600 L

Service Flow Rate:  3 gpm/11.3 lpm

Inlet/Outlet: 1/2” FNPT

2

Содержание ScaleX2 SX2-21

Страница 1: ...tion and performance The OptiPure System is built with the finest and most advanced materials Each system is quality inspected and pressure tested prior to shipment With proper installation and routine maintenance you should have years of trouble free operation Please refer to this manual when performing routine filter changes The instructions make periodic maintenance quick and easy and ensure th...

Страница 2: ...inlet valve closed slowly open the 1 2 full flow ball valve at the tap water source Check for leaks 8 If a drain valve was not installed on the outlet side of the system hold the tubing that will connect to equipment in a clean bucket or over sink or drain Open the system inlet feed valve and allow water to flush through system for ten 10 minutes at the specified system flow rate to allow air and ...

Страница 3: ...hold bleach in a filter bowl of water Let stand 5 minutes and then discard 6 Insert new cartridges into filter housings Match cartridge model numbers to model numbers on bracket 7 Make certain the O ring is properly positioned and reinstall filter housings hand tighten only Check O ring for damage and replace if damaged or distorted 8 Slightly open the inlet ball valve push the red pressure relief...

Страница 4: ...nd certified by NSF International against NSF ANSI Standard 42 for material requirements only NOTE Testing was performed under standard labora tory conditions actual performance may vary It is recommended that you have your water supply tested to determine your actual water conditions For further information regarding OptiPure Certified systems visit the NSF website at www NSF org Replacement Cart...

Отзывы: