![Optimum ESI-100 IP-PBX Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/optimum/esi-100-ip-pbx/esi-100-ip-pbx_manual_1643149005.webp)
ESI-100 IP-PBX
5
Note
: The Card number should correlate to the slot being used. In this case it was slot 2.
When done click Save followed by the
Send Program Changes
button above.
3.2 SIP Programming
To program SIP the SIP port must initially be given an IP address. Navigate to
Program>F8 IP Programming>F84 SIP Card Configuration Programming
and
assign an IP address to the SIP port under
Primary Processor IP
which in this case is
10.10.157.12 /24.
Next navigate to
Program>F2 CO Lines>F21 CO Lines>F214 SIP Line
Programming>F2142 SIP Account Programming
. The
Prov. Num
. field should
be 1. The
ITSP Name
here was “ESI”. The selected vendor was
COX CABLE –BD
and the
Signaling Card
was
2
.
Note
: Due to the limited number of options under
Vendor to select, the COX CABLE –BD option was the one selected for registration
mode. VOXITAS –FS in turn was selected for Static Mode.
The Pilot DID, credentials, and SIP information should be entered in the fields that
follow. The address of the Optimum Business Sip Trunk Adaptor should be entered
under
ITSP URI
and
Outbound Proxy
. The RTP port range was “10000-11000” and
the codec
711
.