Note: The position display cannot be deleted when another status is selected. You have to go
back to the normal display mode first.
4.3
Preset current coordinate value of the axis
Function introduction: When the position display is in the normal display mode, present the dis-
play value of the current position.
Example: Preset the current position of the X-axis as to -12.324.
Operation procedures:
Return to the normal display mode;
Press the
key to select the X-axis
(the indicator light beside the
key is illuminated)
;
Input the
keys;
Press the
key and the X window will display -12.324, indicating that the operation had
been successful, and exit the preset operation automatically.
Note:
-
During the process of entering numerals, the indicator light besides the
key will
flash.
-
During the process of entering value, you can press the
key to cancel the opera-
tion.
-
If the current positions of the Y or Z axes need to be preset, press the key
,
or