QUIT Menu

This menu allows quitting of the configuration menu while saving all the changes 
made.  Simply press “Enter” key at the menu Quit as shown below:

To quit configuration menu without saving changes, press “U” (esc) key.

RESET Menu

The RESET menu resets all the configuration to the default settings.  Note that this 
may leave the device unusable until the user re-calibrates the scale properly.

 

OP-W Series

 

User Manual / Scale Settings

1

 

20/25

Содержание OP-W Series

Страница 1: ...OP W Series User Manual...

Страница 2: ...void overloading or dropping material onto the platform as that could damage the balance Material that has a static charge could influence the performance of the balance Electromagnetic interference c...

Страница 3: ...nu 6 Units Menu 8 Si CAL 01 Menu 11 CALIB Menu 15 FILTER Menu 17 OIML Menu 17 QUIT Menu 20 RESET Menu 20 C1 C2 Menu 21 ADC Menu 21 RST Menu 22 ZERO Menu 22 G1SET Menu 23 G2SET Menu 24 More Info 25 Tro...

Страница 4: ...g Optima scales for your important application Here is the list of models this manual covers Model Max Weight grams Accuracy grams OPW P3 3 000 0 2 OPW P6 6 000 0 5 OPW P15 15 000 1 OPW P30 30 000 2 O...

Страница 5: ...the scale 5 Locate scale in the following condition 1 Temperature 0oC 40oC 6 Plug in the scale to a surge protected power outlet if using the AC adapter You may use the internal rechargeable batterie...

Страница 6: ...r the scale has been turned on and in the normal weighing mode to get to the settings menu follow the procedures below Press the PLU key holding it for more than 2 seconds Press ENTER key OP W Series...

Страница 7: ...guration the user can change For each settings press Enter key to change the value of that particular parameters by using the up down keys to increase decrease the parameters Press Enter key to confir...

Страница 8: ...r will go back to normal weighing mode Units Menu Select the weighing unit the place of the decimal the maximum capcacity and the first rang division and the second rang division if it exists Select t...

Страница 9: ...se the number of decimals after the decimal point Press Enter key On the following screen enter the maximum capacity of the scale For the example below a 5kg max is set Note the decimal places that wa...

Страница 10: ...rang or to exit from the Units menu If the unit does not have the second rang option the message will not show the configuration of the second rang is the same as the configuration of the first rang T...

Страница 11: ...ogrammed from the setting menu G1set and G2set explained later in the document For example we will calibrate the scale in 3 steps 0kg 0 5kg and 1kg When the pan is empty press Enter key The screen wil...

Страница 12: ...ammed by using the arrow keys Put the mass of 0 5kg on the pan let it stabilize and press Enter key The screen will blink while taking the value of the weight When the measurement is done Si 02 will b...

Страница 13: ...using the arrow keys Put the mass of 1kg on the pan let it stabilize and press Enter key The screen will blink while measuring the weight value When the measurement is done Si 03 will be shown to indi...

Страница 14: ...tings menu press the left arrow key To exit with saving configuration select the menu Quit and press Enter key To continue with more configurations using the left and right arrows to traverse and pres...

Страница 15: ...n in 2 steps Press the Enter key and the internal counts is displayed Note may not be exactly the same as this number Press Enter key When the pan is empty press the Enter key to calibration the zero...

Страница 16: ...to program the value of 1kg use the arrow keys to change to 1kg Put the calibration weight in this case 1kg on the pan and press Enter key The screen will blink while taking the value and the setting...

Страница 17: ...NOT follow OIML recommendations 1 Scale does follow OIML recommendations There are 3 sub parameters RS Manual zero limit Adjusts 0 99 from the bottom of the scale It s the capacity for zero ing when...

Страница 18: ...be programmed Press Enter key With this configuration of the RS sub parameter the scale is capable of absorbing the zero deviation 2 from the bottom of the scale For example if the bottom of the scale...

Страница 19: ...is configuration of the OT sub parameter the scale can absorb the zero drifting which are inferior or equal to 40 of the division value For example if the scale is configured for the division of 0 001...

Страница 20: ...at the menu Quit as shown below To quit configuration menu without saving changes press U esc key RESET Menu The RESET menu resets all the configuration to the default settings Note that this may lea...

Страница 21: ...working simultaneously ADC Menu This menu is composed of two sub menus SR speed of ADC 5 10 20 20 is the highest speed GN Amplification of load cell 1 2 2 is when increase of amplification is needed...

Страница 22: ...press U esc key ZERO Menu This menu allows adjusting the number of divisions starting from which it will return to zero There can be 6 values with 0 meaning that the function is not acting The values...

Страница 23: ...acceleration value without decimal point of the location you are interested in If this value is modified a linear calibration Menu Si CAL 01 needs to be performed Press Enter key To quit with save se...

Страница 24: ...librated without the need to re calibrate Press Enter key Enter the gravity acceleration value without the decimal point of the new location s earth gravity Press Enter key To quit with save select Qu...

Страница 25: ...xternal interference Please revisit the Preparation section of this manual Also please make sure the calibration procedure has been performed correctly It won t hurt to run through the calibration pro...