Optima N5024 Скачать руководство пользователя страница 11

 

 

 

INSTRUCTION FOR OPERATION 
 

1.  Before operation 
(1) Wear safety glasses or goggles 
(2) Do not connect the air supply 
(3) Inspect screw tightness 
(4) Check operation of the contact arm & trigger if moving smoothly 
(5) Connect the air supply 
(6) Check the air-leakage.(the tool must not have the air-leakage.) 
(7) Hold the tool with finger-off the trigger, then push the contact arm against the work-

pieces.(the tool must not operate.) 

(8) Hold the tool with contact arm free from work-piece and pull the trigger.(the tool must not 

operate.) 

 
2.  Operation 
Keep hands and body away from the discharge outlet when driving the fasteners because of 
dangerous of hitting the hands or body by mistake. 
 
Nail loading 
(1) Disconnect the air hose. 
(2)  Pull the NAIL FEEDER (324460) down to MAGAZINE (310900)  end,  fix  NAIL  FEEDER          
(324460) on STRAIGHT PIN (324470). 
(3) MAGAZINE COVER B (310840) is opened, feed a strip staples into MAGAZINE (310900), 
slide it towards to NOSE (211250), then feed the second strip, this magazine is capable for two 
strips staples. 
(4) Press STRAIGHT PIN (324470) down, the NAIL FEEDER (324460) is returned back to          
push stales into NOSE (211250). 
(5) Check the staples displayed in magazine compactly and smoothly.  
(6) Connect the air hose. 
 
Test operation 
(1) Adjust the air pressure at 70psi. (5 bar) and connect the air supply. 
(2) Without touching the trigger, depress the contact arm against the work-piece. Pull the 

trigger.(the  tool must fire the fastener.) 

(3) With the tool off the work-piece, pull the trigger. Then depress the contact arm against the 

work-piece.(the tool must fire the fastener.) 

(4) Adjust the air pressure as much as the lowest possible according to the diameters and 

length of fastener and the hardness of work-piece. 

 
 

Содержание N5024

Страница 1: ...derstand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual be...

Страница 2: ......

Страница 3: ...ilers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropr...

Страница 4: ...ssional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident preventi...

Страница 5: ...els which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER S...

Страница 6: ...enever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Страница 7: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Страница 8: ...5 53lbs Actuation mode Contact actuation Magazine capacity 150 staples Maximum allowable pressure 120psi 8 3bar Recommended pressure range 70psi to 100psi 5bar to 7bar Fasteners Only the staple sizes...

Страница 9: ...ly compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The femal...

Страница 10: ...ood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air fi...

Страница 11: ...n to MAGAZINE 310900 end fix NAIL FEEDER 324460 on STRAIGHT PIN 324470 3 MAGAZINE COVER B 310840 is opened feed a strip staples into MAGAZINE 310900 slide it towards to NOSE 211250 then feed the secon...

Страница 12: ...he nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In c...

Страница 13: ...MPER 71 610730 BOLT M5X14 23 110580 BODY 72 324450 SAFETY 24 410140 HANDLE GRIP 73 621480 SAFETY SPRING 25 511620 O RING 44X2 45 74 610820 NUT M5 26 520370 END CAP SEAL 75 610760 BOLT M5X16 27 110590...

Страница 14: ...TOOL SCHEMATIC N5024...

Страница 15: ......

Страница 16: ...N5024 Wide Crown Stapler 1708...

Отзывы: