NOTE: 

Products can be learned repeatedly, but all products 

must be studied with the same product.   

 

3: Clear interconnection code   

If you want to cancel networking: 
1): Push and hold the test button, then power on alarm, the 

red LED will illuminate. Keep pressing the test button till 
the LED turns off. 

2) Press the test button again, the LED will illuminate and 

start flashing. When the LED stops flashing, the code has 
been successfully cleared and the device is back in its 
initial state.   

 
4: Radio link test 

To ensure that all the products have been successful learning. 
1): Select one device, press and hold the button for about 2 

seconds until the device goes into 

“test alarm mode” 

and 

then  release  the  button,  the  device  will  auto  send 

“radio 

link test” 

information. 

2):

 

After short delay, all other devices will go into

 “radio link 

test” 

status  for  5  minutes  (red  led  flashes  twice  every 

second,  no  audible  signal).  If  not,  the  device  network 
learning  failure  or  the  distance  between  the  connected 
devices  is  too  large  (the  connected  devices  cannot  reach 
each other).   

NOTE: 

In 

“radio  link  test” 

status  device,  press the  button 

and the device immediately enters the normal standby 
mode. 

NOTE: 

Before installing, place the product in each installed 

room and select the device in the farthest room for this 
test, to ensure that other products successfully enter the 

"radio link test"

 status. 

 

Trouble shooting: 

Problem 

Method of disposal 

 

 

 
Smoke  alarm  device 
does  not  sound  when 
tested.   

1. Fit the alarm on the bracket and 

turn the alarm body clockwise for 
POWER ON.   

2. Clean smoke alarm device. Please 

refer  to  the  “maintenance  and 
cleaning” section. 

3.  If  still  not  working  contact 

supplier.   

The  alarm  “chirp” 
with red LED flashing 
once every 40 seconds.   

The  battery  is  getting  low  and 
smoke alarm unit must be replaced. 

Smoke alarm device 

Clean  smoke  alarm  device.  Please 

chirp      occurs every 
40 seconds

alarm 

goes into fault 
mode

refer  to  the  “maintenance  and 
cleaning”  section.  If  after  cleaning 
as  directed,  problem  still  exists 
contact supplier.   

Smoke  alarm  device 
sounds 

unwanted 

alarms  intermittently 
or  when  residents  are 
cooking, 

taking 

showers, etc. 

1. Press test button to put alarm into 

silence mode.   

2. Clean smoke alarm device. Please 

refer  to  the  “maintenance  and 
cleaning” section. 

3. Move smoke alarm device to new 

location and press test button.   

 

 
The  alarm  sound  is 
distorted  and  different 
from its original sound 
and starts and stops.   

1. Clean smoke alarm device. Please 

refer  to  the  “maintenance  and 
cleaning” section. 

2.  If  fault  continues  please  contact 

supplier.   

Maintenance and Cleaning: 

The alarm requires periodic cleaning to remove dust, dirt, and 
debris. 
Use a vacuum cleaner with the soft brush, vacuum all sides 
and covers of device.   
The AU981 smoke alarm has a low battery indicator, the alarm 
will “chirp” approx every 40 seconds and the red LED light 
will flash once at the same time for a minimum of thirty days 
when  the  battery  gets  low.  AU981  smoke  alarm  must  be 
replaced when this occurs. 

WARNING: 

The battery is sealed and not replaceable. 

IMPORTANT:

 Do not attempt to remove the cover to clean

 

 

  inside. This will affect the warranty. 

Repair: 

Caution: 

Do  not  attempt  to  repair  the  smoke  alarm.  It  will 

affect your warranty. Contact your supplier. 

 

Wall Position for Installation: 

·

Smoke, heat and flames are most likely to spread horizontally               

after  rising  to  the  ceiling,  so  if  possible  install  the  smoke 
alarm unit in the middle of the ceiling   

·

If    the  smoke  alarm  unit  is  unable  to  be  installed  in  the 

middle of the ceiling please ensure it is at least 30cm in from 
the corner. (see diagram 1). 

·

If  you  are  installing  the  smoke  alarm  unit  on  the  wall,  it 
should be installed lower than 10cm but no more than 30cm 
below the ceiling (see diagram 1).   

·

If the length of the room or the hall is greater than 9 metres, 

Отзывы: