5  C-HP baSIC featureS

C-HP is a multiple interfaces (HDMI + USB2.0 + SD card) CMOS camera. 

HDMI + USB2.0 are used as the data transfer interface to HDMI display or computer.

For HDMI output, the Camera Control Panel+ Measurement Toolbar and Camera Control Toolbar are overlaid 

on the HDMI screen when the mouse move to the related region.

In this case, the USB mouse can be used to set the camera, browse and compare the captured image, play the 

video and perform the measurement.

For USB Video camera mode, plug in the micro USB host cable to the camera USB video port and computer 

USB port, then the video stream can be transfer to computer with the advanced software ProView. With ProView, 

you can control the camera, process the video and image as OPTIKA's other USB series camera.

The C-HP’s basic characteristics are as follows:

For HDMI output:

•  All in 1(HDMI + USB + SD card) C-mount camera with Sony high sensitivity CMOS sensor;

•  Simultaneous HDMI & USB output;

•  Built-in mouse control;

•  Built-in image capture & video record to SD card;

•  Built-in  camera  control  panel,  including  exposure(manual/auto)/gain,  white  balance(lockable),  color 

adjustment, sharpness control;

•  Built-in video and image measurement; 

•  Built-in toolbar including zoom, mirror, comparison, freeze, cross, browser functions;

•  Built-in image & video browsing, display & play;

•  Real time clock (RTC) 

For USB Video output:

•  Ultra-Fine color engine with perfect color reproduction capability(USB);

•  With advanced video & image processing application ProView, which including professional image proces

-

sing such as 2D measurement, HDR, image stitching, EDF(Extended Depth of Focus), image segmenta

-

tion & count, image stacking, color composite and denoising (USB);

•  Support standard UVC protocol for Windows (USB); 

 

 

C-HP - SW UI for Mouse Control 

5.1  Quick Instructions for C-HP camera

 

Figure 1 - The Layout of C-HP Rear Cover

Before starting the camera, please connect the standard C-HP C-mount camera to the camera adapter and in

-

sert it into the microscope’s photo tube which will relay microscope object’s middle image to the camera sensor.

5.2  uSb video Mode

1. 

Plug 12V/ 1A power cable into DC 12V slot to supply power for the camera. The LED Indicator will turn into 

red;

2. 

Press ON/OFF Button to start the camera and the LED indicator will turn into blue;

3. 

Plug the USB cable which comes with the camera into USB Video to connect the video to the computer;

4. 

Open ProView software, start C-HP by clicking the camera model name listed in Camera List. For more 

details please refer to the ProView help manual;

5.3  HDMI Mode

1. 

Plug the HDMI cable into the HDMI Port to connect the C-HP camera to HDMI display;

2. 

Plug a USB mouse into USB Mouse to get control of the camera by using built-in software ProView;

3. 

Plug 12V/ 1A power adapter into Power Interface to supply power for the camera. The LED Indicator will 

turn into red;

4. 

Insert SD card into SD Card Slot for saving captured images and recorded videos;

5. 

Press ON/ OFF Buttonto start the camera. The LED Indicator will turn into blue;

6. 

Move mouse cursor to the left side of the video window, a Camera Control Panel will appear. It includes 

Manual/ Automatic Exposure, White Balance, Sharpness and other functions, please refer to2.1 for details;

7. 

Move mouse cursor to the bottom of the video window and a Camera Control Toolbar will appear. Opera

-

tions like Zoom In, Zoom Out, Flip, Freeze, Cross Line, Comparison and etc. can be realized. Please refer 

to 2.2 for details;

8. 

Move mouse cursor to the upper side of the video window, a Measurement Toolbar with calibration and 

other measurement tools will appear, please refer to 2.3 for details. The measurement data can be output 

with *.CSV format.

① HDMI connector

② USB mouse connector

③ USB PC connector

④ SD card slot

⑤ Power supply plug

⑥ ON-OFF button

② ③

⑤ ⑥

Содержание C-HP

Страница 1: ...Model C HP HDMI Cameras H Series Insci v 2 0 2018 ...

Страница 2: ...nce and that it must therefore be made accessible to the instrument users We decline any responsibility deriving from incorrect instrument use uses that does not comply with this manual 2 msdcis The following chart is an illustrated glossary of the symbols that are used in this manual CAUTON ELETRALO 3 mi AE 4 dds For research and teaching use only Not intended for any animal or human therapeutic ...

Страница 3: ...used to set the camera browse and compare the captured image play the video and perform the measurement For USB Video camera mode plug in the micro USB host cable to the camera USB video port and computer USB port then the video stream can be transfer to computer with the advanced software ProView With ProView you can control the camera process the video and image as OPTIKA s other USB series came...

Страница 4: ...Panel will not pop up automatically even if users move mouse cursor to left side of the video windows Only when user left clicks the button on the Measurement Toolbar to exit from measuring procedure will they be able to do other operations on the Camera Control Panel or Synthesis Camera Control Toolbar During the measuring process when a specific measuring object is selected an Object Location At...

Страница 5: ...ideo Display Cross Line Browse Images and Videos in the SD Card Settings Check the Version of ProView Setting function is relatively more complicated than the other functions Here are more info about it Figure 3 Measurement Settings Page Global beside the measuring patterns mentioned above will unfold the corresponding Figure 4 Magnification Calibration Management Settings Page Name ...

Страница 6: ...t Angle Arbitrary Line Parallel Horizontal Line Vertical Line Rectangle Circle Ellipse Annulus Two Circles and Center Distance Arc Polygon Curve Make Calibration to determine the corresponding relation between magnification and resolution this will establish the corresponding relationship between measurement unit and the sensor pixel size Calibration needs to be done with the help of a micrometer ...

Страница 7: ...Right Move Up Move Down Color Adjustment and Delete Note 1 on the Measurement Toolbar the Measurement Toolbar will be fixed In this case the Camera Control Panel will not pop up automatically even if moving mouse cursor to the left side of the video window Only when users left click the button on the Measurement Toolbar to exit from the measurement mode they will be able to doing other operations ...

Отзывы: