background image

 

 

2

  / 

10

 

 

1.

 

Features 

 

Czerny-Turner optical design for high resolution & maximum throughput while minimizing stray light 

& aberrations 

 

Dual ruled gratings used for high efficiency ultraviolet to visible wavelength scanning 

 

Single output port version with CCD detector 

 

Micrometer adjustable slits 

 

Utility software and an ActiveX Control file included 

 

Control with USB and RS-232 

 

Nitrogen connector is available for UV and NIR testing 

 

Entrance is compatible with our light sources and fiber interface 

 

Exit is compatible with our single-point detector and other accessories 

 

The precision worm & gear structure guarantee the high accuracy and repeatability 

 

Optics chamber and mechanical drive chamber are separated to reduce stray light and pollution to 

optical components 

 

2.

 

Description 

This series of Spectrometers is a high performance, economical and user-friendly spectrometer – an ideal 

instrument for research and OEM applications. 

 

This  series  of  Spectrometers  uses  an  asymmetrical  in-plane  Czerny-Turner  optical  configuration.  The 

optical  configuration  is  designed  to  ensure  high  resolution  and  maximum  throughput.  The  F/4.5 

Spectrometer  is  optimized  to  provide  excellent  stray  light  rejection  while  minimizing  aberrations.  Its 

wavelength  drive  is  designed  to  increase  speed  as  much  as  possible  without  sacrificing  accuracy  or 

precision. 

 

Utility software is included to control both the spectrometer and filter wheel. An ActiveX Control file and 

an  easy-to-understand  command  set  are  provided  for  those  wanting  to  create  their  own  programs  by 

LabView or other programing languages. 

Содержание 7ISW152

Страница 1: ...0 10 User Manual 7ISW152 Spectrometer Optics Focus Instruments Co Ltd ...

Страница 2: ...ts 1 Features 2 2 Description 2 3 Specifications 3 4 Specifications of Optional Gratings 3 5 CCD Specifications 4 6 Optical Design 5 7 Slits Adjustment 6 8 Usage 6 9 Others 7 10 Utility Software 8 11 Accessories 9 ...

Страница 3: ...mber are separated to reduce stray light and pollution to optical components 2 Description This series of Spectrometers is a high performance economical and user friendly spectrometer an ideal instrument for research and OEM applications This series of Spectrometers uses an asymmetrical in plane Czerny Turner optical configuration The optical configuration is designed to ensure high resolution and...

Страница 4: ... Wavelength Selection Method Motorized Output Ports 1 with CCD detector Slits Micrometer Slit Slits Height 5mm Slits Width 10µm 3mm Communication Interfaces RS232 and USB Size 298mmx200mmx185mm Center Height of Light Path 140mm 5mm Weight 10kg 4 Specifications of Optional Gratings Grating Model Linear Dispersion nm mm Accuracy nm Repeatability nm Resolution nm Theoretical Spectral Range nm Mechani...

Страница 5: ...0 1000 660 2000 OG600 1250 830 2200 OG300 500 21 6 1 0 0 4 1 6 330 1000 0 4400 OG300 1250 830 2500 OG300 1800 1200 3600 OG300 3000 2000 4400 OG150 4000 43 2 2 0 0 8 3 2 2600 8000 0 8800 OG66 DB 97 4 6 1 8 7 3 2500 25000 0 20000 OG50 12000 130 6 2 4 9 6 8000 24000 0 26400 5 CCD Specifications Manufacturer TOSHIBA Pixel Size 8μm 200μm Pixel Number 3648 SNR 60dB A D 16Bit Exposing Time 1ms 100ms PC I...

Страница 6: ...and changes the off axis angle to correct coma improves symmetry of spectral lines and improves resolution Eliminating secondary dispersion is designed to restrain stray light The F 4 5 spectrometer is optimized to provide excellent stray light rejection while minimizing aberrations 7ISW152 spectrometer optical design ...

Страница 7: ...per revolution 8 Usage Cable Connection Connect 9 pin connector of spectrometer to the RS232 serial port of computer Or connect the spectrometer to computer by USB line If you have bought our 7IFW6 filter wheel please connect 15 pin connector of spectrometer to the 9 pin connector of 7IFW6 filter wheel Connect the CCD to computer by USB line After connecting all the cables firmly turn on the power...

Страница 8: ...are and select the actual RS232 port the communication will be successful You can use software to operate the instrument to automatically change the wavelength scan spectrum switch gratings and change filters if you have bought 7IFW6 filter wheel from us Please refer to the software manual The spectrometer should be power on when using CCD The wavelength range of CCD need to be set by the spectrom...

Страница 9: ...gas so you can keep filling it during the whole experiment to keep the nitrogen concentration and positive pressure in the instrument The excess gas will leak off through gaps 10 Utility Software The utility software is included at no extra cost with all models to control both the monochromator Spectrometer and filter wheel accessory The utility software provided with the monochromator Spectromete...

Страница 10: ...9 10 Utility Software Screens 11 Accessories 1 x 220V line cord or 110V line cord 1 x RS232 cable 1 x USB cable 1 x USB cable for CCD 2 x 3A fuse 1 x Nitrogen connector ...