Opticon
OPV 1001
Specifications Manual
34
13. Durability
13.1. Static Electricity
Air discharge:
±8 kV max. (No malfunction)
±15 kV max. (No destruction)
Contact discharge:
±4 kV max. (No malfunction)
±8 kV max. (No destruction)
Measurement
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Discharge resistance: 330
Ω
Capacitor charging:
150 pF
13.2. Shock
13.2.1.
Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 100 cm onto a concrete floor
(three times on each of 6 sides).
Figure 28: Drop test
13.2.2.
Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop an individually packaged scanner from a height of 100 cm
onto a concrete floor once on its 1 corner, 3 edges, and 6 sides (10 total drop
tests).
13.3. Vibration Strength
No malfunction occurred after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz with
accelerated velocity 19.6 m/s
2
(2 G) for 60 minutes in non-operating state. Repeat this
routine in each X, Y, Z direction once for 60 minutes each.