Opticon OPV 1001 Скачать руководство пользователя страница 1

Laser Multi-barcode Scanner 

OPV 1001 

 

The OPV 1001 is a 1000 scans multi-barcode laser 
scanner reading for omni-directional reading.

 

Specifications Manual 

 

 

Содержание OPV 1001

Страница 1: ...Laser Multi barcode Scanner OPV 1001 The OPV 1001 is a 1000 scans multi barcode laser scanner reading for omni directional reading Specifications Manual...

Страница 2: ...that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair ch...

Страница 3: ...2 AC Adapter 9 5 3 Operating Indicators 9 5 3 1 Red 9 5 3 2 Green 9 6 Optical Specifications 10 6 1 Laser Scan Specifications 10 7 Technical Specifications 10 7 1 Print Contrast Signal PCS 10 7 2 Min...

Страница 4: ...9 1 3 DOS V Wedge Cable 27 9 2 Connectors 27 10 Default Settings 27 10 1 Set Default Interface 27 10 2 Default Settings 1 Readable Codes 29 10 3 Default Settings 2 Read Options Trigger Buzzer 30 11 Se...

Страница 5: ...42 19 Safety 43 19 1 Shock 43 19 2 Temperature Conditions 43 19 3 Foreign Materials 43 19 4 Other 43 20 Mechanical Drawing 44 20 1 OPV 1001 without stand 44 20 2 OPV 1001 with stand 44 Table of Figure...

Страница 6: ...Figure 21 Wedge connector DOS V side 25 Figure 22 RS 232C cable 26 Figure 23 USB cable 26 Figure 24 Wedge cable 27 Figure 25 Serial number diagram 31 Figure 26 Individual packaging diagram 32 Figure 2...

Страница 7: ...d when the brightness in front of the scanner is changed for example when an object is placed in front of the scanner You can use a dedicated stand an accessory sold separately to adjust the height an...

Страница 8: ...nce is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light 3 000 lx Fluorescent light 3 000 lx Sunlight 20 000 lx Conditions Barc...

Страница 9: ...nds on the interface type and the host computer to which the device is connected 5 2 AC Adapter Input Input voltage AC 90 V to 264 V Power supply frequency 47 Hz to 63 Hz Maximum current up to 400 mA...

Страница 10: ...Conditions Ambient temperature and humidity Room temperature 5 to 35 C Room humidity 45 to 85 RH Ambient light 500 to 1000 lx Background Barcode black Space white Margin white Background of label bla...

Страница 11: ...barcode surface However the barcode should be set within the following area Figure 1 Scan area Note Binary codes are more likely to cause scanning errors than multi level codes To minimize problems f...

Страница 12: ...higher 0 2 15 110 0 9 0 127 15 50 Resolution mm Symbology Digit Barcode Sample 0 66 JAN 8 8 OPTOELECTRONICS Test Sample 0 33 JAN 13 13 OPTOELECTRONICS Test Sample 0 2 Code 39 7 Laser printer labels 0...

Страница 13: ...13 7 4 Pitch Skew and Tilt 7 4 1 Pitch Angle 35 Figure 3 Pitch 7 4 2 Skew Angle and Dead Zone Skew angle 50 Excluding dead zone Dead zone 8 There are some areas in which decoding fails due to specular...

Страница 14: ...CTRONICS Test Sample Distance 70 mm from the front edge of the scanner Label Pitch Skew Angle PCS 0 9 Resolution 0 33 mm Symbology JAN 13 Position The center of the barcode and the scan line are almos...

Страница 15: ...8 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 25 mm Figure 6 Curvature Conditions Barcode S...

Страница 16: ...8 bits Parity bits No parity Handshaking No handshake Flow control time out Indefinitely You can change the communication condition using the menu barcode 8 1 2 Signal Level Signal Name I O RS 232C L...

Страница 17: ...ifications Manual 17 8 1 4 Interface Circuit Figure 7 Interface circuit RS 232C 8 1 5 Character Format Figure 8 Character format same for both sending and receiving 8 1 6 Communication Format Figure 9...

Страница 18: ...d whether they can receive data with BUSY READY through an RTS line They can communicate state to each other through a CTS line when connected as in the following figure Figure 11 Busy Ready communica...

Страница 19: ...0 ms I3 Figure 12 Handshaking Busy Ready CTS TxD Signals Timing When the CTS line RTS signal on the host side is turned OFF while sending a TxD signal the scanner transmits one character and waits Whe...

Страница 20: ...Opticon OPV 1001 Specifications Manual 20 c MODEM The scanner turns RTS line ON before transmitting data Other processes are the same as BUSY READY Figure 14 Handshaking Modem mode...

Страница 21: ...the initial state NAK response Action The scanner sends the data again and waits for the response from the host DC1 response Action The scanner returns to waiting for the trigger if it has a trigger t...

Страница 22: ...RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the sam...

Страница 23: ...Manual 23 8 2 USB Interface Specifications 8 2 1 Connector a USB A connector Figure 17 USB A connector Contact Number Signal Name Notes 1 VCC Power signal 2 DATA 3 DATA 4 GND 8 2 2 Interface Circuit...

Страница 24: ...DOS V Host Side Figure 19 Wedge connector host side Contact Number Signal Name Notes 1 CPU DATA 2 KEY DATA 3 GND 4 VCC Power signal 5 CPU CLOCK 6 KEY CLOCK b DOS V Keyboard Side Figure 20 Wedge conne...

Страница 25: ...Side Figure 21 Wedge connector DOS V side Contact Number Signal Name Notes 1 CPU DATA 2 OPEN 3 GND 4 VCC 5 CPU CLOCK 6 OPEN Note To connect a PS2 port that supports both a mouse and a keyboard please...

Страница 26: ...edge only Diameter 3 8 mm main cable 3 mm AC adapter cable Length 2000 50 mm excluding main cable and connector 250 20 mm excluding AC adapter cable and jack Cores 8 insulated wires 1 conductive wire...

Страница 27: ...Wedge interface Mini DIN 6 pin female connector USB interface USB A connector 10 Default Settings 10 1 Set Default Interface Scan the following menu barcodes to return to the default settings RS 232C...

Страница 28: ...s SET _ZZ_ ZZ USB VCP _C0_ C01 END _ZZ_ ZZ Wedge with keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT Wedge _UB_ UB With keyboard _KM_ KM END _ZZ_ ZZ Wedge without keyboard Functions Menu lab...

Страница 29: ...NW 7 X X CR Not transmit ST SP Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 93 X X CR Code 128 X X CR EAN 128 X X X CR IATA X X CR Industrial2of5 X X CR Interleaved2of5 X X CR ISBN Japan co...

Страница 30: ...zzer Item Default Setting Setting the number of characters Fixed length OFF all codes Read mode Multiple read Multiple read reset time 500 ms Add on wait mode 500 ms Multiple column read Disable Redun...

Страница 31: ...Opticon OPV 1001 Specifications Manual 31 11 Serial Number The serial number shown below is affixed to the scanner Figure 25 Serial number diagram...

Страница 32: ...N BAG G B 8 700 4 57 S T A N D S E T B LA C K X FO P E 0007 A C A D A P T O R w i t h 4P l ugs S T A N D S E T O S E U ser s M anual 5J0063A O S E U ser s M anual P ut A C A dapt or P l ugs A C A D A...

Страница 33: ...Label Attach this label when there are more than 3 labels of which serial numbers are out of order not in a correct sequence U N I V E R S A L C N o M A D E I N JA P A N P r oduct M O D E L PO S pec...

Страница 34: ...scanner from a height of 100 cm onto a concrete floor three times on each of 6 sides Figure 28 Drop test 13 2 2 Drop Test with individual packaging No malfunction occurred after the following drop te...

Страница 35: ...urface and attach a weight of 250 grams Swing the cable back and forth at an angle of 60 degrees Repeat 500 000 times Figure 29 Cable tail bending test 14 Reliability MTBF Mean Time Between Failures o...

Страница 36: ...he trigger is continuously depressed 15 2 Read modes Single read mode When a symbol has been decoded the reader will be turned off The reader must be triggered again to read another symbol This option...

Страница 37: ...sable Settings Use the following settings to enable or disable the auto trigger Auto trigger is disabled by default To enable auto trigger scan ZZ I and ZZ in that order To disable auto trigger scan Z...

Страница 38: ...ween 1 and 9999 seconds by reading 1 up to 4 direct input numeric characters from chapter String options A value of 0 default means that the barcode reader enters the idle state if the read time has e...

Страница 39: ...1 Q2 Q3 Q4 9999 seconds BBB Q9 Q9 Q9 Q9 Disable power saving mode ZZ BBB ZZ 17 3 Power Saving 2 Motor Rotation 1 2 Functions Menu labels Menu codes SET _ZZ_ ZZ Motor half speed when idle _BBA_ BBA Ena...

Страница 40: ...Opticon OPV 1001 Specifications Manual 40 Figure 31 Menu code combinations part 1...

Страница 41: ...Opticon OPV 1001 Specifications Manual 41 Figure 32 Menu code combinations part 2...

Страница 42: ...used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or televisi...

Страница 43: ...hrow the scanner into the fire Do not forcibly bend the cables at low temperatures 19 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 19 4 Other Do no...

Страница 44: ...1001 Specifications Manual 44 20 Mechanical Drawing 20 1 OPV 1001 without stand Figure 33 Mechanical drawing without stand 20 2 OPV 1001 with stand 1 0 0 9 2 1 4 5 1 1 2 Figure 34 Mechanical drawing...

Отзывы: