Opticon OPH1000 Скачать руководство пользователя страница 2

 

G

RAPHICAL 

D

EMO 

A

PPLICATION FOR 

OPH1000 OPTICON 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CAUTION: This user’s manual may be revised or withdrawn at any time without prior notice. 
 

 
 

Version

 

 

User’s manual for Graphical demo application 
 
Model: OPH1000 
 
Version: XFA30920 
 
Operating System (OS) version: XBAV0104 or higher 
 
February 2007 
 
 
 

Copyright 2007, Opticon Sensors Europe B.V. 
All rights reserved.

 

 
Limited warranty and disclaimers 
By opening the package of this product you agree to become bound by the liability and warranty 
conditions as described below. 
 
Under all circumstances this manual should be read attentively, before installing and or using the 
product. In no event,  
 
Opticon Sensors Europe will be liable for any direct, indirect, consequential or incidental damages 
arising out of use or inability to use both the hardware and software, even if Opticon has been informed 
about the possibility of such damages. 
 
All Opticon products are warranted for a period of one year after purchase, covering defects in physical 
media and physical documentation. The liability of Opticon is limited to replacement of defective media 
or documentation. 
 
Opticon will not be liable for modifications that are made by the customer. Opticon does not warrant that 
the software is free of errors, or that it will meet any user’s particular standards, requirements, or needs. 
Opticon will in no event be liable for any direct, indirect or incidental damages arising out of use of this 
software. 
 
Trademarks used are property of their respective owners. 

Содержание OPH1000

Страница 1: ...GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON Graphical Demo Application Manual Version XFA30920 for OPH1000 For Operating System versions XBAV0104 or higher...

Страница 2: ...Europe will be liable for any direct indirect consequential or incidental damages arising out of use or inability to use both the hardware and software even if Opticon has been informed about the pos...

Страница 3: ...O APPLICATION FOR OPH1000 OPTICON Table of contents TABLE OF CONTENTS 3 1 KEYS 4 2 THE MENU STRUCTURE 5 2 1 Scan Labels 6 2 2 Scroll data 7 2 3 Transmit Data 8 2 4 Delete Database 9 2 5 System Menu 10...

Страница 4: ...has full alphanumeric keypad with some additional control keys including the following The Q1 key Up key or left key with shift The Trigger key The Q2 key Down key or right key with shift While holdin...

Страница 5: ...ough the menu and items may be selected by pressing the ENT or the Trigger button Direct selection of the menu is also possible by pressing the numeric equivalent of the menu item Below is the schemat...

Страница 6: ...ess the ENT or Trigger keys To return to the main menu press the CLR key The data entered now appears on the display Total indicates the current quantity in the database If the entered data does not e...

Страница 7: ...r 999999 then an error message appears The added quantity is not stored in the database After pressing a key the scan barcode menu appears After entering the quantity the application returns to the sc...

Страница 8: ...ult NetO Protocol Port Default Cradle Baudrate Default 115200 Parity Default None Databits Default 8 Stopbits Default 1 When the transmit data message appears on the display put the OPH1000 in the cra...

Страница 9: ...e You may select this menu item if you wish to delete the entire database from the OPH1000 You are then asked to confirm your choice You can now press ENT to delete the database or CLR to cancel and r...

Страница 10: ...System menu contains a submenu where special terminal options can be viewed or set The navigation of this menu behaves the same as the main menu The system menu consist of 6 items Com Port Protocol D...

Страница 11: ...The Port setting controls how you connect your device to the PC The OPH1000 supports two methods including IrDA and Cradle The default setting is Cradle The Baudrate menu allows you to select a baudra...

Страница 12: ...ct which type of parity your code uses You can choose from 1 None Default 2 Even 3 Odd The Databits menu allows you to select the number of databits used in your code You can choose from 1 7 2 8 Defau...

Страница 13: ...ds data from the database as flat ascii The NetO protocol sends data to the PC using the NetO protocol Checked protocol enabled Unchecked protocol disabled By selecting a new protocol the previous sel...

Страница 14: ...pported barcode types include UPC Default EAN Default Code 39 Default Codebar Default Industrial 2 of 5 Default Interleaved 2 of 5 Default S Code Default Matrix 2 of 5 Chinese Post IATA Code Default M...

Страница 15: ...n the RAM disk is almost full a message appears The remaining memory is needed for data communication from the Transmit Data menu RAM disk is almost full data is stored RAM disk is full data is not st...

Страница 16: ...GRAPHICAL DEMO APPLICATION PAGE 16 GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON 2 6 Version The version menu allows you to view the current software version The software version of this application...

Страница 17: ...ters right padded with spaces Quantity 7 characters left padded with spaces 6 numeric and 1 sign bit Time stamp 8 characters format HH MM SS Date stamp 10 characters format DD MM YYYY The record field...

Страница 18: ...GRAPHICAL DEMO APPLICATION PAGE 18 GRAPHICAL DEMO APPLICATION FOR OPH1000 OPTICON...