Manual No. 25-NLB0045-01
Series NLB-9625/9645 Mini Laser Fixed Position Scanner
Page 23
Parameters modified by downloading software commands remain in effect only while power is supplied to the
scanner. If power is interrupted or terminated, the parameters return to their original settings. However, param-
eters programmed by downloaded commands can be stored permanently by transmitting a Z2 computer
command to the scanner after the commands are sent. this instructs the scanner to store the changed parameter(s)
in non-volatile memory. The scanner will then retain the setting(s) permanently or until changed.
It is not necessary to send a Z2 command after each parameter is changed. One Z2 command will save all
changes.
Example
: If programming the scanner to decode only Code 128 bar code were
desired, the following command would be used:
<ESC> A6 <CR>
The scanner will now only decode Code 128 bar codes and will ignore other types
of bar code. The scanner will retain this setting until power is interrupted or
terminated, and will then revert to its original setting. If retaining this setting
permanently is desired, the following command would be used:
<ESC> A6 <CR>
<ESC> Z2 <CR>
The Z2 command stores the modified parameter in non-volatile memory. The
scanner will not retain this setting even after power is terminated.