MEK-1001 TS07004
5
Table 5: CN_2 12-pin Connector Signals for MDL-1000 and MDL-2000 series
(Opposite pin assignments from the ones of scan engines.)
Signal
No.
Name
Function
I/O
Control
Notes
1
Trigger
Start operation signal
Out
L: Start operation
H: No action
(When in power down mode)
Recovery signal from the power
down state
Out
L: Recovery from the
power down state
H: No action
2
AIM/WUPn
(When not in power down mode)
Aiming control signal
Out
L: Aiming LED ON
H: Aiming LED OFF
There are products which do
not support LED.
3
Decode LED
In
L: LED ON
H: LED OFF
Controlled by the command
4
BUZZER
Buzzer sounding signal
In
L: Buzzer OFF
PWM: Buzzer ON
PWM signal controls the tone
and the loudness of buzzer
5
POWER
DOWN
Notifies power down state of the
scan engine
In
L: Normal state
H: Power down state
6
RTS
Comm. Control signal to the host
In
Data output request from the
scan engine
7
CTS
Comm. Control signal from the
host
Out
Data output request to the
scan engine
8
TxD
Data reception signal
In
Asynchronous data
transmission to the host.
9
RxD
Data transmission signal
Out
Asynchronous data
transmission from the host.
10
GND
System ground
11
V
CC
3.3V-power supply output
Out
12
TEST
Maintenance mode control signal
Out
L: Maintenance mode
H or Open: Normal
Enters into a maintenance
mode when the signal is
turned to L-level.
Note: Signal names are the same with the signal names of MDL scan engines.