background image

2 - OPTICON   PHL4100/IRU4100

LIMITED WARRANTY AND 
DISCLAIMERS

BY OPENING THE PACKAGE OF THIS PRODUCT YOU 
AGREE TO BECOME BOUND BY THE LIABILITY AND 
WARRANTY CONDITIONS AS DESCRIBED BELOW.

UNDER ALL CIRCUMSTANCES THIS MANUAL 
SHOULD BE READ ATTENTIVELY, BEFORE 
INSTALLING AND OR USING THE PRODUCT.

Serial number 

A serial number appears on all Opticon products. This 
official registration number is strictly related to the device 
purchased. Make sure that the serial number appearing on 
your Opticon device has not been removed. Removing the 
serial number might affect the warranty conditions and 
liability disadvantageously, so please be strict at 
maintaining the label with serial number on the Opticon 
product.

Warranty / Warranty period / Liability

Unless otherwise agreed in a contract, all Opticon 
products are warranted for the period of one year after 
purchase, covering defects in material and workmanship. 
Opticon will repair or, at its opinion, replace products that 
prove to be defective in material or workmanship under 
proper use during the warranty period. Opticon will not be 
liable in cases where modifications are made by the 
customer. In such case the standard repair charge will be 
applicable. The standard charge for repair will also be 
applicable in cases where no defect is found at all. These 
rules also apply for products that are still under warranty. 
Under no circumstance will Opticon Sensors Europe, be 
liable for any direct, indirect, consequential or incidental 
damages arising out of use or inability to use both the 
hardware and software, even if Opticon has been informed 
about the possibility of such damages.

Packaging

We recommend that you save all packing material, as it 
should be used whenever you need to transport your 
scanner (eg. for service). Damage caused by improper 
repacking is not covered by the warranty.

Trademark

Trademarks used are property of their respective owners.

CAUTION: This information is subject to change 
without prior notice. 

Copyright 2003, Opticon Sensors Europe B.V. 
All rights reserved.

This manual may not, in whole or in part, be 
copied, photocopied, reproduced, translated or 
converted to any electronic or machine readable 
form without prior written consent of Opticon 
Sensors Europe.

THE GENERAL USE AND FUNCTIONING OF 
THE TERMINAL TOGETHER WITH THE CRADLE 
IS DESCRIBED IN THIS MANUAL. THE EXACT 
BEHAVIOUR OF THE TERMINAL DEPENDS ON 
THE USER APPLICATION THAT IS RUNNING. 
FOR INSTRUCTIONS ABOUT APPLICATIONS 
CONSULT THE DOCUMENTATION OF THAT 
SOFTWARE. 

Содержание IRU 4100

Страница 1: ...PHL4100 IRU4100 OPTICON 1 PHL 4100 IRU 4100 USER S MANUAL Opticon Article Code O0220000140...

Страница 2: ...case the standard repair charge will be applicable The standard charge for repair will also be applicable in cases where no defect is found at all These rules also apply for products that are still u...

Страница 3: ...5 How to re place main battery in terminal 14 2 2 6 When to replace backup battery 15 2 2 7 How to re place backup battery 15 2 3 Working with stylus 16 2 4 Using a PCMCIA card 17 2 4 1 Insert PCMCIA...

Страница 4: ...rated laser scanner for barcode scanning For communication the terminal is provided with an IrDA and a PCMCIA interface By inserting the appropriate PC card in the PCMCIA slot the terminal can exchang...

Страница 5: ...please contact your supplier PHL 4100 contents Terminal A Hand strap B Rechargeable battery LBP 4100 C Backup battery D PHL 4100 accessories Rechargeable battery LBP 4300 E Battery cover for LBP 4300...

Страница 6: ...ing status of communication 4 Touch screen LCD Display Operate by stylus to tap through menus Take notice of the following Contrast of LCD Display To increase contrast of display press FN To decrease...

Страница 7: ...CLR Cancel input Back space FN define by user application scroll up backwards scroll down forward EN Enter to confirm input Each character key has 3 appearances in combination with the Modus M key ALP...

Страница 8: ...ost through Opticon RS232 cable 3 Electrical contacts If the PHL4100 terminal is inserted the battery will automatically be charged 4 Optical window Optical communication interface for data transmissi...

Страница 9: ...place any objects on top of the terminal Do not lay the terminal face down Doing so can cause accidental operation of the key s C Use of the products Use the terminal always with the cap mounted in o...

Страница 10: ...first Read instructions in this manual If required Insert PCMCIA card For PCMCIA data exchange the appropriate card needs to be inserted Read instructions in this manual Place the cradle in normal off...

Страница 11: ...ns Fix the small thin cord of the strap around the pillar of the terminal ref 1 Insert the handle cord of the strap into the thin loop ref 2 TO AVOID DROP HOLD THE HAND STRAP AROUND THE WRIST WHEN CAR...

Страница 12: ...he rechargeable Opticon battery as supplied with the terminal The main battery can be a standard type LBP 4100 or a larger type with more capacity LBP 4300 See also product ordering information In thi...

Страница 13: ...be charged The charging procedure is fully automated Charging in IRU 4100 cradle Place the cradle in normal office conditions Make sure the power supply is connected to the cradle The battery needs to...

Страница 14: ...FICIENT CAPACITY TO AVOID DATA LOSS Unlock main battery case cover ref 1 Unlock the case cover by use of a coin by turning the latch screw a quarter counter clockwise Remove old battery by simply taki...

Страница 15: ...minal faced down The adapter is now positioned on the right side Loosen the 2 screws of the adapter by use of a small crosshead screwdriver or swatch screwdriver Slide the adapter to the outside Remov...

Страница 16: ...terminal face up the stylus is located at the right lower corner Release stylus ref 1 Hold your fingernail in the saving of the stylus Pull the stylus outwards with some force Storing stylus The stylu...

Страница 17: ...PCMCIA connector into the terminal When a small card is inserted gently push with the stylus to connect into the slot Place cap Place the cap back on the terminal Fix the cap by screwing the two cap...

Страница 18: ...able is used take notice of the pin out specifications further in this manual Start Switch off the power supply of the host computer Choose proper place ref 1 Place the cradle in normal office conditi...

Страница 19: ...oring the terminal Make sure all data is safely stored If you have data stored on the terminal make sure the data is transmitted to the host system Remove main battery Remove backup battery Keep the c...

Страница 20: ...ill be indicated A Good Read means that the scanner has effectively recognised and decoded the bar code In most cases the application program will provide an indicator signal or a buzzer signal to ind...

Страница 21: ...T DO NOT CHANGE PIN OUT OF CABLES AS SUPPLIED FROM OPTICON RS232 cable pin out Serial plug DB 9 M Signal DB 9 M Serial plug DB 9 F Signal DB 9 F 3 TxD 2 RxD 2 RxD 3 TxD 6 1 DSR 4 DTR 5 GND 5 GND 4 DTR...

Страница 22: ...e product clean Are the bar code labels damaged Check if the error also occurs with other bar code labels Product does not operate Check if the battery requires charging Check if the power key respond...

Страница 23: ...rminal The type of the bar code label is not enabled If applicable enable the bar code symbology in the application program The error occurs consistently with a certain batch of labels Verify the barc...

Страница 24: ...the LED should turn red If the cradle LED is red and the battery is not properly charged clean the charging contacts of the charger The terminal application uses a lot of power Depending on the type...

Страница 25: ...IP 54 Display 240 x 160 Pixels touchscreen Main battery pack Li Ion Pack 1cell UF 1011 7V 1700mAh Backup battery Lithium CR2032 Light source 650 nm visible laser diode Scan rate 100 scans sec Decode r...

Страница 26: ...2 supported by cradle Interface IrDA supported on terminal Interface PCMCIA PCMCIA 16 Bit Wireless LAN Cisco Aironet 350 series 2 4 GHz Spread Spectrum Wi Fi IEEE 802 11b GSM GPRS Option Globetrotter...

Страница 27: ...55022 EN 55024 Voltage requirement 6 V DC Battery charging time automatically determined Parity Odd Even None Stop bit 1 or 2 Interface RS232 supported Transmission speed baud rate 2400 115200 bps Tr...

Страница 28: ...evelopment kit DEVELOPMENT KIT FOR PHL4100 D0000000040 Product description Article name Article code Charger for 1 battery of PHL 4100 4300 CHARGER PHL4100 PHL4300 X1 OC100000010 Power supply for char...