4
Environmental Specifications
4.1
Operating Temperature and Humidity
Temperature: 0 to 70° C
Humidity: 20% to 85% RH
4.2
Storage Temperature and Humidity
Temperature: -20 to 70° C
Humidity: 20% to 85% RH
4.3
Static Electricity
Air discharge:
± 8 kV (No malfunction / Automatic recovery)
± 15 kV (No damage but operator involvement may be required)
Contact discharge:
± 4 kV (No malfunction / Automatic recovery)
± 8 kV (No damage but operator involvement may be required)
4.4
Drop resistance.
The EBS-50 has withstood the following drop test:
Drop the base station 12 times (3 times at each of 4 orientations), from a height of 1m onto a
concrete floor as shown below. Note the position of the antennas.
Figure 5: Drop test
4.5
Dust and Drip Proof
This product has not undergone any IP tests. The intended use is indoor only.