background image

USER MANUAL                         

(VER. 7A) 

DVI Matrix Router 

– ODM1818 

 

 

DVI Input 2

    PC

DVI Output

 Display 18

DVI Input 1

    PC

DVI Input 18

    PC

DVI Output

 Display 1

Control PC

Internet

USB

RS-232

Содержание ODM1818

Страница 1: ...USER MANUAL VER 7A DVI Matrix Router ODM1818 DVI Input 2 PC DVI Output Display 18 DVI Input 1 PC DVI Input 18 PC DVI Output Display 1 Control PC Internet USB RS 232...

Страница 2: ...g the Router ID of ODM1818 9 2 2 Front Panel Interface 10 2 3 CREATE Mode 10 2 4 PREVIEW Mode 10 2 5 CANCEL Mode 11 2 6 FUNCTION Mode 11 2 6 1 MONITOR OUTPUT SELCTION 11 2 6 2 RS 232 BAUD RATE 11 2 6...

Страница 3: ...C Application 30 3 4 2 Installation of USB Driver 32 3 4 3 PC Operation using RS 232 34 3 4 4 PC Operation using Ethernet 34 3 5 Control Buttons 36 3 6 File menu 37 3 7 Edit Pattern 37 3 8 Rolling Fun...

Страница 4: ...DVI cables or modules Re Clocking of R G B of DVI inputs and outputs Various Control Interfaces Front panel key input Input commands through RS 232 LAN and USB Graphical user interface using Ethernet...

Страница 5: ...wn occurs contact factory immediately 1 4 Physical Description 1 4 1 Front Panel ODM1818 chassis is mountable on a 19 standard rack with rack ears Control keys Input Output buttons and the status LCD...

Страница 6: ...single link DVI inputs Eight 18 single link DVI outputs DIP switch 8 bits to set ID identifier in case of multiple connection of ODM1818 USB B type receptacle port RS 232 Serial port 10 100 Base Ethe...

Страница 7: ...type phosphor or filter type timings supported by the display display size luminance data and for digital displays only pixel mapping data Once the graphic source reads the information set usually dur...

Страница 8: ...cables and modules for extended distance ODM1818 supports connection of Optical DVI cables or modules to all inputs and outputs The use of copper DVI cables over 3m 10ft is not recommended 1 7 Initia...

Страница 9: ...5 cable 1 Point to point Ethernet connection of PC or video controller to the ODM1818 When PC is connected to the network dynamic IP address is configured by net work DHCP server But if the PC is conn...

Страница 10: ...press ENTER to escape current setting press another control key i e CREATE or PREVIEW 2 3 CREATE Mode Configures Input Output connections for cross switching 1 Press CREATE button once to activate ora...

Страница 11: ...D Save Factory mode 2 6 1 MONITOR OUTPUT SELCTION To verify the video source press FUNCTION key once 1 Connect a display to the MONITORING port and any video sources to the DVI Input ports on the rear...

Страница 12: ...0 Press ENTER button to complete the process and return to the User mode 2 6 4 SUBNET MASK press FUNCTION four times The Under Bar mark represents selected and activated Pressing Input 1 9 button chan...

Страница 13: ...are in common use for formulating a MAC address Each ODM1818 is shipped with its own MAC ADDRESS The MAC ADDRESS of ODM1818 can be edited however it is strongly not recom mended Editing MAC ADDRESS T...

Страница 14: ...t respec tively Press ENTER button to complete the configuration store the information and execute the process 2 6 9 COMMNAD TYPE press FUNCTION nine times Command type function is used to operate ODM...

Страница 15: ...n Description Dialog Enter a name and choose an icon Figure 2 2 Connection Description Dialog 4 Selecting OK displays the Connect To dialog In the Connect To dialog box ignore the Country Area Code an...

Страница 16: ...ommunication with ODM1818 9 Type serial command set Refer to Chap 3 2 2 7 2 Telnet Telnet is a terminal emulation program for TCP IP networks such as the Internet The Telnet program runs on your compu...

Страница 17: ...OK to open the command window 4 Type the command telnet 192 168 0 44 Note 192 168 0 44 is the default IP address of ODM1818 To change IP address refer to Chap 2 6 6 and 2 8 5 Press ENTER DVI Matrix Ro...

Страница 18: ...5 The default IP address is 192 168 0 44 2 8 1 SETTING THE IP ADDRESS of the PC If the PC is connected to the ODM1818 through the 10 100 Base Ethernet port a static address should be configured on the...

Страница 19: ...nection to ODM1818 is only valid with proprietary PC software command line interface cannot be used For its device installation and instruction refer to the Proprietary PC Software Operation in Chap 3...

Страница 20: ...t 17 to Output 18 Input 18 no connection Operation is executed in two steps Set EDID for each Input port for proper graphic signal transmittal Configure Input Output for cross switching as configured...

Страница 21: ...or setting procedures The commands are coded in ASCII and HEXA All descriptions are shown in Table 3 1 A command line consists of string of ASCII or HEXA codes in series as shown below Start 1 Byte Ro...

Страница 22: ...rate of RS 232 Read Output Device EDID A 0x41 Read EDID from attached display Default EDID Setting B 0x42 Restore factory default EDID on EEPROM Read Input EEPROM C 0x43 Read EDID from EEPROM EDID Wr...

Страница 23: ...yte End Example 1 One 1 channel connection of Output Channel 1 and Input Channel 1 Start Router ID Command Data Length Output Channel Input Channel End ASCII 2 5 5 0 0 0 4 0 1 0 1 HEX 2Ah 32h 35h 35h...

Страница 24: ...er ID 3 byte Command 1 Data Length 000 End 3 2 3 Cancel Cancels configuration of outputs for each Input Command line format Start Router ID 3 byte Command 2 Data Length variable Input Channel 2 byte E...

Страница 25: ...and outputs by changing them in se quence Format of Command Line Start Router ID 3 byte Command 4 Data Length Variable Output Channel 2 byte Input Channel 2 byte End Ex To rotate three 3 inputs 1 2 an...

Страница 26: ...tput channel Input channel End 0 2 0 1 0 3 0 2 30h 32h 30h 31h 30h 33h 30h 32h 21h 3 2 7 Upload Router ID Uploads Router ID to the controller or PC Command line format Start Router ID 3 byte Command 5...

Страница 27: ...hannel Data Request Upload connection status of a selected Output channel Command line format Start Router ID 3 byte Command 8 Data Length 002 Output channel 2 byte End Input 6 Output 1 connection Byt...

Страница 28: ...3 byte Command C Data Length 002 Input EEPROM 2 byte End Example Read EDID stored on EEPROM of Input 2 Byte Start Router ID Command Data Length Input EEPROM End ASCII 2 5 5 C 0 0 2 0 2 Hex 2Ah 32h 35h...

Страница 29: ...ommand Data Length EEPROM 1 EEPROM 2 ASCII 2 5 5 D 0 1 6 0 1 0 3 Hex 2Ah 32h 35h 35h 44h 30h 31h 36h 30h 31h 30h 33h EEPROM 3 EEPROM 18 END 0 0 0 0 30h 30h 30h 30h 21h 3 2 14 Default EDID Setting Rest...

Страница 30: ...itoring Data End ASCII 2 5 5 G 0 0 2 0 2 Hex 2Ah 32h 35h 35h 47h 30h 30h 32h 30h 32h 21h 3 3 Web Control Panel Operation The web control panel WCP provides a graphic alternative to command line interf...

Страница 31: ...8 ODM1818 Manual Edition 7a Page 31 2 Installation of ODM1818 screen will be opened select NEXT 3 Select the destination directory path then select Install 4 To complete the installation select the OK...

Страница 32: ...1 Connect ODM1818 to PC using USB cable then turn on ODM1818 2 Select Install from a list or specific location Advanced then select NEXT 3 Insert CD ROM then select Search for the best driver in these...

Страница 33: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 33 5 Select FINISH to complete installation...

Страница 34: ...ea and begins loading of switching patterns from router 7 If incorrect cable COM port or Router ID is detected message Device Not Found will appear on the status display 8 Verify that cable is securel...

Страница 35: ...the switching patterns 4 Message box will display Overwrite Y or Insert N Select Y Overwrite the old switching data Select N Create new switching pattern 5 Enter new pattern name then select Accept 6...

Страница 36: ...8 Process flow Cre Button Input Button Output Button Ent Button Pre Preview Verifies current Input Output connection status same function as the Preview Button on front panel of ODM1818 Process Pre Bu...

Страница 37: ...e Downloads current Input Output channel patterns from PC Application to the router Upload Pattern from Device Uploads current Input Output channel patterns from router to the PC Application Exit Term...

Страница 38: ...anual Edition 7a Page 38 Scrolling the mouse over the Input numbers will display current connection Users can check the switching pattern database in the program folder c program files ODM1818 Add 1 S...

Страница 39: ...the combo box 3 Select Modify similar to Save As in windows Delete 1 Select the pattern name to be deleted 2 Select Delete 3 Selected pattern name is deleted from the combo box list 3 8 Rolling Functi...

Страница 40: ...2 4 3 5 4 1 5 The lowest channel Input LED and connected Output channel LED on Router will be turned on In this case Input 1 and Output 1 will be tuned on 3 8 1 Single Rolling Select Single The Outpu...

Страница 41: ...ID Example Four 4 sources with four 4 different types of displays configured as below Source Input 1 is distributed to Output 1 and 4 1 Source 1 Display 1 1080p 2 Source 2 Display 2 3 Source 3 Display...

Страница 42: ...to save the EDID data Note Check 1 1 Same number will be assigned for EEPROM and Output All EEPROM Select all EEPROM Set Default EDID All EEPROM is reset to factory default values 3 9 5 Read EDID 1 Se...

Страница 43: ...ice 1 Select Files and go to EDID setting 2 Select Write EDID Data from Output Device tab on top 3 Select Read EDID from Output Device in EDID Read information 4 Select the number of Output Device and...

Страница 44: ...etting 2 Select File open to recall saved EDID data 3 The EDID information will appear in the Edit EDID Write EDID Data from Output Device 1 General 3 9 8 EDID EDIT 1 Select Files and go to EDID setti...

Страница 45: ...d double check the Input Output connection configuration you want The display is not capable of handling graphic resolution Check the compatibility of EDID in the EEPROM and attached displays When a s...

Страница 46: ...status on 20x4 LCD and with illuminated LED type keys 6 Be rack mountable with solid 19 inch standard RACK TYPE CASE 7 Supports real time Hot Plug Detection and program each EDID to connected DVI sour...

Страница 47: ...n of the Ponyprog2000 PonyProg 2000 is a firmware update software program for ODM1818 Follow the instructions below to install the PonyProg2000 software into your PC Insert the software CD into your P...

Страница 48: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 48 Define destination directory and click Next button...

Страница 49: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 49 Select Start Menu Folder as below Select Install button to install the software in your PC...

Страница 50: ...SER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 50 Select Finish then PonyProg2000 will be installed in your PC successfully Select Install button to install the software in your P...

Страница 51: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 51 Select Finish then PonyProg2000 will be installed in your PC successfully...

Страница 52: ...ODM1818 Manual Edition 7a Page 52 7 2 Download of Firmware Turn on the Router and connect Router to Download port and PC to Parallel port over firmware download cable Execute PonyProg2000 exe and clic...

Страница 53: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 53 Select AVR micro as below Select AT mega128 as below...

Страница 54: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 54 Select Interface Setup in Setup menu as below Set I O port as below and click OK button...

Страница 55: ...ct Security and Configuration Bits in Command menu Select the Read button and make sure the option is set as below If the option is not same as below click the Clear All and mark it as below Then clic...

Страница 56: ...USER MANUAL DVI MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 56 Select Open Program FLASH File in File menu and select new firmware to download Select Write Program FLASH in Command menu...

Страница 57: ...MATRIX ROUTER ODM1818 ODM1818 Manual Edition 7a Page 57 Select OK button to starts downloading and verifying process in order Select OK to terminate the downloading Now the Router is operated under t...

Страница 58: ...act your Distributor or Reseller For technical support visit Opticis web site www opticis com or contact techsupport opticis com Opticis Locations Opticis Co Ltd 501 Byucksan Technopia 434 6 Sangdaewo...