OPERATOR MANUAL 

 
 
 
 
 

OSD2254P SERIES 

6-PORT REDUNDANT RING 

GIGABIT ETHERNET SWITCH WITH 

PoE++ SOURCE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание OSD2254P Series

Страница 1: ...OPERATOR MANUAL OSD2254P SERIES 6 PORT REDUNDANT RING GIGABIT ETHERNET SWITCH WITH PoE SOURCE ...

Страница 2: ......

Страница 3: ...ION SETUP 21 2 5 2 COMMAND LINE FUNCTIONS 22 3 MAINTENANCE 27 3 1 INTRODUCTION 27 3 2 EXTERNAL INSPECTION 27 3 3 ROUTINE MAINTENANCE 27 4 WARRANTY 28 4 1 WARRANTY PERIOD 28 4 2 REPAIRS 28 4 2 1 WARRANTY REPAIRS 28 4 2 2 OUT OF WARRANTY REPAIRS 28 4 2 3 SITE REPAIRS 28 4 2 4 EXCLUSIONS 28 FIGURE 1 OSD2254P TYPICAL RING CONFIGURATION 5 FIGURE 2 OSD2254P PORT ALLOCATION 8 FIGURE 3 OSD2254P MOUNTING D...

Страница 4: ...GY CHECK 24 FIGURE 20 LOCAL NODE CHECK 25 FIGURE 21 VERSION CHECK 26 TABLE 1 TECHNICAL SPECIFICATIONS 7 TABLE 2 DC OR AC POWER CONNECTION 11 TABLE 3 ALARM CONNECTIONS 12 TABLE 4 LED FUNCTION 15 TABLE 5 OSD2254P 8 WAY DIP SWITCH SETTINGS 16 TABLE 6 CURRENT LIMITING SWITCH SETTINGS 17 TABLE 7 TERMINAL COMMAND LINES 22 ...

Страница 5: ...lly switch to a secondary path in less than 2ms per hop to maintain ring network integrity The OSD2254P has Power over Ethernet PoE function and operates as a Power Source Equipment PSE The OSD2254P PoE can provide up to 60W to each RJ45 port to Powered Devices PD The unit will operate on either singlemode or multimode fiber Operation over a network of hundreds of kilometers is possible by use of ...

Страница 6: ...se of cable or switch failures takes less than two milliseconds per hop MDI MDIX Crossover no need for crossover cables Supports IEEE802 3af at Alternative B cable wiring Can be used with either singlemode or multimode fiber over a variety of link budgets Available for operation over 1 or 2 fibers Auto Negotiation for half or full duplex operation Complies with the IEEE802 3af at standard includin...

Страница 7: ...Connectors RJ45 Alarms Ring to Bus High Temperature Alarm Interface Optoisolated MOSFET rated at 100mA 46V maximum PoE IEEE802 3af IEEE802 3at and PoE Operating Mode Alternative A B Pins 1 2 3 6 4 5 and 7 8 Optical Port Connectors SFP SFP Options Short haul long haul single fiber operation etc Please consult OSD DATASHEET 100210000x or contact OSD Indicators 4x Copper Link 4x Copper Activity 4x Po...

Страница 8: ...mm terminal block power connector and a 4way 3 5mm terminal block alarm connector Bottom Panel 8 Way DIP switch Micro USB connector and a Type B USB connector Each section will be described further throughout this manual FIGURE 2 OSD2254P PORT ALLOCATION Front Panel Top Panel Bottom Panel Power Port Alarm Port Configuration Port Micro USB Port Console Port Copper Port 1 Copper Port 2 Copper Port 3...

Страница 9: ...uct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard Class 1 The OSD2254P is a Class 1 laser product PRECAUTIONS All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures d...

Страница 10: ...UAL PAGE 10 2 2 2 OSD2254P DRAWINGS AND DIMENSIONS The OSD2254P is designed to be wall mounted onto a DIN Rail 35mm top hat fixture The unit dimensions excluding connectors SFPs etc is shown in Figure 3 below FIGURE 3 OSD2254P MOUNTING DIMENSIONS 43mm 91mm 130mm ...

Страница 11: ... longevity and reliability It is thus good engineering practice to ensure the unit is installed in a well ventilated area 2 2 4 POWER SUPPLY CONNECTIONS The OSD2254P requires external power to the Redundant DC Terminal Block Power Connector located at the top of the unit Always ensure that the power is off before any installation Redundant DC Terminal Block Power Inputs There are two pairs of powe...

Страница 12: ... out in Table 3 There are four pins on the 3 5mm terminal block used alarm output Maximum ratings the OSD2254P relay can drive is 100mA 46V max Note Alarm output has no polarity TABLE 3 ALARM CONNECTIONS Alarm Output Alarm1 Ring Bus Status Alarm CH2 Temperature Open Ring Less than 90 C Closed Bus Higher than 90 C Note Bus alarm is only triggered after a ring connection is established FIGURE 5 ALAR...

Страница 13: ...tor See section 2 5 for further CLI information FIGURE 7 USB TYPE B CLI PORT To operate and control the OSD2254P using the CLI an OSD2254P driver will be required to be installed onto the PC being used The driver can be found on the included CD or on the OSD website Please contact OSD sales if the driver cannot be found or installed For Windows XP Vista and Windows 7 CP210x_VCP_Win_XP_S2K3_Vista_7...

Страница 14: ...OPTICAL SYSTEMS DESIGN DOC ID 10115206 OSD2254P OPERATOR MANUAL PAGE 14 FIGURE 8 WIN XP INSTALLATION ...

Страница 15: ...CATORS FIGURE 9 PORT LED TABLE 4 LED FUNCTION No Function LED Colour Function On Blink Off Green Gr Am Amber Activity No Activity 1Gbps Link No Link On Link Activity No Link 1Gbps 100Mbps Power No Power Power Ring Bus Initial Ring Bus Load Detect No Load LD Always Amber in non ring mode ...

Страница 16: ...ON FUNCTION SWITCH POSITION 1 Current Limiting See Table 6 for Current Limiting function OFF 2 Current Limiting See Table 6 for Current Limiting function OFF 3 Not Used OFF 4 Not Used OFF ON 5 Ring Bus Ring Non Ring OFF ON 6 Port 5 Fiber Speed 1000Mbps 100Mbps OFF ON 7 Port 6 Fiber Speed 1000Mbps 100Mbps OFF ON 8 Programming Mode Normal Operation Programming Mode OFF ON Default settings Ϯ PD depen...

Страница 17: ...D precautions should be taken when installing Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Remove plastic rubber dust cap and fit fiber cable or RJ45 plug Removing SFP Remove fiber connector or RJ45 plug Pull the SFP lever down to un...

Страница 18: ... fiber used must be 9 125µm singlemode fiber For multimode fiber connections fiber used must be 50 125µm or 62 125µm multimode fiber Plug in the appropriate connectors for system configuration RJ45 cable to fixed copper ports port 1 and 2 and copper SFP modules LC or SC fiber cable to fiber SFP modules Redundant Ring Operation The OSD2254P connected in a redundant ring topology providing maximum r...

Страница 19: ...ed line indicates the closed loop but more OSD2254P units can be connected to the ring as required using this topology Ensure that the switch settings for port 5 and 6 are set to 1000Mbps 1Gbps see Table 5 FIGURE 14 REDUNDANT RING CONNECTION Bus Operation To connect the OSD2254P in a bus configuration ports 5 and 6 must be used together with fiber SFPs The remaining ports ports 1 2 3 4 should be u...

Страница 20: ...NUAL PAGE 20 2 4 TYPE A USB PORT The Micro USB Port is used for uploading firmware updates All OSD2254P units will be shipped with the latest firmware already installed This port has no function for end user FIGURE 16 OSD2254P MICRO USB CONNECTOR Micro USB Port ...

Страница 21: ...priate cable as specified in section 2 2 6 Using a terminal emulation program such as Hyperterminal a number of command lines specific to the OSD2254P can be implemented to check link node status ring bus topology and enable disable float backup 2 5 1 TERMINAL EMULATION SETUP Using a terminal emulation program such as hyperterminal the following parameters should be set up for correct command line...

Страница 22: ... the user wishes to interrogate Note A message will be displayed on the terminal emulation program when the unit is powered after USB connection This message will not open when the unit is switched on while plugging in the USB cable however the command lines are functional The following table outlines the user available command line commands and their functions TABLE 7 TERMINAL COMMAND LINES TERMI...

Страница 23: ...whether the unit is either the Master or Slave on the ring bus in this case only one unit is connected thus displaying master The Master unit is determined by the unit with the lowest MAC address PORT3 U_port Indicates the function of port 3 and its relation to the ring bus There are four possibilities 1 M_port Master Port port facing the master 2 S_port Slave Port port back to the master 3 B_Port...

Страница 24: ...t is either the Master or Slave on the ring bus Master is determined by the lowest MAC address PORT3 U_port Indicates the function of port 3 and its relation to the ring bus There are four possibilities 1 M_port Master Port 2 S_port Slave Port 3 B_Port Backup Port 4 U_Port Unconnected Port PORT4 U_port Indicates the function of port 4 and its relation to the ring bus There are four possibilities 1...

Страница 25: ... PAGE 25 LOCAL NODE CHECK lnc Command Line FIGURE 20 LOCAL NODE CHECK This command line displays the running status of the local node that the USB cable is plugged into The information provided is the MAC address Topology Node Role Port Role and Float Backup status ...

Страница 26: ...AL SYSTEMS DESIGN DOC ID 10115206 OSD2254P OPERATOR MANUAL PAGE 26 VERSION CHECK vc Command Line FIGURE 21 VERSION CHECK Displays the Software Version Number and Software ID Number installed on the OSD2254P ...

Страница 27: ...be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visually check for the following Check that the correct power source is connected to the power socket Check that the Ethernet cables are connected ...

Страница 28: ...ative for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods Freight costs and insurance for both journeys are met by the user All equipment repaired by OSD will have a 3 Month Warranty from the date of dispatch 4 ...

Страница 29: ...OPTICAL SYSTEMS DESIGN DOC ID 10115206 OSD2254P OPERATOR MANUAL PAGE 29 ...

Страница 30: ...Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N 83 003 020 504 Printed in Australia ...