OPTICAL SYSTEMS DESIGN
DOC ID: 10115703
OSD2153 OPERATOR MANUAL
PAGE 16
The following tables outline the recommended switch settings for the OSD2153. Any changes in switch
settings require power up to take effect.
TABLE 5: CONFIGURATION WITH LLF ENABLED
Configurations
Case1
Case2
Case3
Case4
Switch
Setting
Configurations
1. LLF detects fiber &
copper
2. LLF is enabled
3. Fiber port is
100BASE-X
1. LLF detects fiber &
copper
2. LLF is enabled
3. Fiber port is
1000BASE-X
1. LLF detects fiber
only
2. LLF is enabled
3. Fiber port is
100BASE-X
1. LLF detects fiber
only
2. LLF is enabled
3. Fiber port is
1000BASE-X
Fiber link
loss
Response
Action
Disable Tx of copper port
Disable Tx of copper port
Restore
Sequence
1. Fix fault and reconnect
2. Wait for link to be reestablished
1. Fix fault and reconnect
2. Wait for link to be reestablished
Copper
link loss
Response
Action
Disable Tx of fiber port
NULL
Restore
Sequence
1.Fix fault and reconnect
2.Wait for link to be reestablished
NULL
TABLE 6: CONFIGURATION WITH LLF DISABLED
Configurations
Case1
Case2
Switch
status
Configurations
of SIP switch
1. Invalid
2. LLF is disabled
3. Fiber port is
1000BASE-X
1. Invalid
2. LLF is disabled
3. Fiber port is
1000BASE-X
1. Invalid
2. LLF is disabled
3. Fiber port is
100BASE-X
1. Invalid
2. LLF is disabled
3. Fiber port is
100BASE-X
Fiber link
loss
Response
Action
NULL
NULL
Restore
Sequence
NULL
NULL
Copper
link loss
Response
Action
NULL
NULL
Restore
Sequence
NULL
NULL