67
5. Code Reference
Related information code will be displayed on LCD screen. Please check inverter LCD screen for the operation.
Code
Description
Action
If battery status is not allowed to charge and
discharge after the communication between
the inverter and battery is successful, it will
show code 60 to stop charging and discharging
battery.
Communication lost (only available when the
battery type is setting as “Pylontech Battery”,
“WECO Battery” or “Soltaro Battery”.)
After battery is connected, communication
signal is not detected for 3 minutes,
buzzer will beep. After 10 minutes,
inverter will stop charging and discharging
to lithium battery.
Communication lost occurs after the
inverter
and
battery
is
connected
successfully, buzzer beeps immediately.
Battery number is changed. It probably is
because of communication lost between
battery packs.
Press “UP” or “DOWN” key to switch LCD
display until below screen shows. It will
have battery number re-checked and 62
warning code will be clear.
If battery status is not allowed to charge after
the communication between the inverter and
battery is successful, it will show code 69 to
stop charging battery.
If battery status must to be charged after the
communication between the inverter and
battery is successful, it will show code 70 to
charge battery.
If battery status is not allowed to discharge
after the communication between the inverter
and battery is successful, it will show code 71
to stop discharging battery.