opti-solar SP5000 Power-M Скачать руководство пользователя страница 20

18 

 

19 

Automatically return to 
default display screen 

Return to default 

display screen 

(default) 

 

If selected, no matter how users 

switch display screen, it will 

automatically return to default display 

screen (Input voltage /output voltage) 

after no button is pressed for 1 

minute.   

Stay at latest screen 

 

If selected, the display screen will stay 

at the latest screen user finally 

switches.   

20 

Backlight control 

Backlight on (default) 

 

Backlight off   

 

22 

Beeps while primary 
source is interrupted 

Alarm on (default)     

 

Alarm off 

 

23 

Overload bypass: 
When enabled, the unit 
will transfer to line mode if 
overload occurs in battery 
mode. 

Bypass disable 

(default) 

 

Bypass enable 

 

 

25 

Record Fault code

 

Record enable             

 

Record disable (default) 

 

26 

Bulk charging voltage 
(C.V voltage) 

Default setting: 56.4V 

 

If self-defined is selected in program 5, this program can be set 

up. Setting range is from 48.0V to 58.4V. Increment of each 

click is 0.1V. 

27 

Floating charging voltage 

Default setting: 54.0V 

 

If self-defined is selected in program 5, this program can be set 

up. Setting range is from 48.0V to 58.4V. Increment of each 

click is 0.1V. 

28 

AC output mode   
*This setting is able to set 
up only when the inverter 
is  in  standby  mode.  Be 
sure  that  on/off  switch  is 
in “OFF” status. 

Parallel  output  in  single 

phase. Output voltage is 

120V.   

 

Support L1 phase output on 

3-Phase application. Output voltage 

is 120V. 

 

 

Содержание SP5000 Power-M

Страница 1: ...SP5000 Power M Hybrid Solar Inverter Version 1 1 User Manual...

Страница 2: ...10 Communication Connection 10 Dry Contact Signal 10 OPERATION 11 Power ON OFF 11 Operation and Display Panel 11 LCD Display Icons 12 LCD Setting 14 Display Setting 21 Operating Mode Description 24 Fa...

Страница 3: ...nance or cleaning Turning off the unit will not reduce this risk 5 CAUTION Only qualified personnel can install this device with battery 6 NEVER charge a frozen battery 7 For optimum operation of this...

Страница 4: ...suit different applications via LCD setting Configurable priority of AC Solar Charger via LCD setting Compatible to mains voltage or generator power Automatic restart while AC is recovering Overload...

Страница 5: ...PV input 7 Parallel communication port only for parallel model 8 Current sharing port only for parallel model 9 Parallel ID Please check chapter 6 in Parallel Function for setting details 10 AC outpu...

Страница 6: ...ow Mounting the Unit Consider the following points before selecting where to install Do not mount the inverter on any flammable construction materials Mount this inverter on a solid surface Install th...

Страница 7: ...afety and efficient operation to use appropriate cable for battery connection To reduce risk of injury please use proper cables and suitable size of terminal recommended below Recommended battery cabl...

Страница 8: ...tween the flat part of the inverter terminal and the ring terminal Otherwise overheating may occur CAUTION Do not apply any anti oxidant substance on the terminals before the terminals are connected t...

Страница 9: ...NING It s very important for system safety and efficient operation to use appropriate cable for AC input connection To reduce risk of injury please use the recommended cable size as below Suggested ca...

Страница 10: ...on terminal block and tighten the terminal screws Be sure to connect PE protective conductor first Ground yellow green L1 LINE black L2 LINE brown N Neutral blue WARNING Be sure that AC power source...

Страница 11: ...modules and PV input connectors Then connect positive pole of connection cable to positive pole of PV input connector Connect negative pole of connection cable to negative pole of PV input connector 3...

Страница 12: ...ar panel It could be used to deliver signal to external device when battery voltage reaches warning level Unit Status Condition Dry contact port NC C NO C Power Off Unit is off and no output is powere...

Страница 13: ...the operating status and input output power information LED Indicator LED Indicator Messages Green Solid On Output is powered by utility in Line mode Flashing Output is powered by battery or PV in bat...

Страница 14: ...with fault code Output Information Indicate output voltage output frequency load percent load in VA load in Watt and discharging current Battery Information Indicates battery level by 0 24 25 49 50 74...

Страница 15: ...d 20 1 867V cell 1 867V cell 1 95V cell 1 95 2 033V cell 2 033 Load Information Indicates overload Indicates the load level by 0 24 25 50 50 74 and 75 100 0 25 25 50 50 75 75 100 Mode Operation Inform...

Страница 16: ...dition stated below happens Solar energy is not available Battery voltage drops to either low DC warning voltage or the setting point in program 12 Utility first default Utility will provide power to...

Страница 17: ...solar charging current 40A 50A 60A default 70A 80A 90A 100A 110A 120A 130A 140A 150A 160A 170A 180A 190A 200A 210A 220A 03 AC input voltage range Appliances default If selected acceptable AC input vol...

Страница 18: ...art enable 07 Automatically restart when over temperature occurs Restart disable default Restart enable 08 Output voltage 110V 120V default 09 Output frequency 50Hz 60Hz default 11 Maximum utility cha...

Страница 19: ...arge battery as first priority Utility will charge battery only when solar energy is not available Utility first Utility will charge battery as first priority Solar energy will charge battery only whe...

Страница 20: ...if overload occurs in battery mode Bypass disable default Bypass enable 25 Record Fault code Record enable Record disable default 26 Bulk charging voltage C V voltage Default setting 56 4V If self def...

Страница 21: ...fault When ONE is selected as long as one of the inverters has been connected to PV modules and PV input is normal parallel or 3 phase system will continue working according to rule of solar first set...

Страница 22: ...ter will judge this charging time automatically 5 min The setting range is from 5 min to 900 min Increment of each click is 5 min 900 min If USE is selected in program 05 this program can be set up 33...

Страница 23: ...ay Setting The LCD display information will be switched in turns by pressing UP or DOWN key The selectable information is switched as the following table order Selectable information LCD display AC In...

Страница 24: ...200W MPPT Input 2 Charging current MPPT Input 2 Charging power PV2 voltage 60V PV2 Power 200W Load 1 Watt Load 1 percentage Load 1 Watt 200W Load 1 percent 60 Load 2 Watt Load 2 percentage Load 2 Wat...

Страница 25: ...rging current Battery voltage Charging current 25A Battery voltage 56 0V Battery voltage DC discharging current Battery voltage 53 0V discharging current 1A Main CPU version checking Main CPU version...

Страница 26: ...AC output No output is supplied by the unit but it still can charge the batteries Charging by utility Charging by PV energy Charging by PV energy and utility No charging Fault mode Note Fault mode Er...

Страница 27: ...V power Power from battery and PV energy Power from battery only Fault Reference Code Fault Code Fault Event Icon on 01 Fan is locked when inverter is off 02 Over temperature 03 Battery voltage is too...

Страница 28: ...synchronization loss Warning Indicator Warning Code Warning Event Audible Alarm Icon flashing 01 Fan is locked when inverter is on Beep three times every second 03 Battery is over charged Beep once ev...

Страница 29: ...50Vac Nominal Input Frequency 50Hz 60Hz Auto detection Low Loss Frequency 40 1Hz Low Loss Return Frequency 42 1Hz High Loss Frequency 65 1Hz High Loss Return Frequency 63 1Hz Output Short Circuit Prot...

Страница 30: ...age load 20 44 0Vdc 20 load 50 42 8Vdc load 50 40 4Vdc Low DC Warning Return Voltage load 20 46 0Vdc 20 load 50 44 8Vdc load 50 42 4Vdc Low DC Cut off Voltage load 20 42 0Vdc 20 load 50 40 8Vdc load 5...

Страница 31: ...charge 34Vdc Standby Power Consumption 23W Battery Voltage Accuracy 0 3 PV Voltage Accuracy 2V Charging Algorithm 3 Step Joint Utility and Solar Charging INVERTER MODEL SP5000 Power M Max Charging Cur...

Страница 32: ...and LEDs are flashing Battery is disconnected Check if battery wires are connected well Buzzer beeps continuously and red LED is on Fault code 07 Overload error The inverter is overload by 110 and tim...

Страница 33: ...in SP5000 Power M 500 1226 2576 1000 536 1226 1500 316 804 2000 222 542 2500 180 430 3000 152 364 3500 130 282 4000 100 224 4500 88 200 5000 80 180 Note Backup time depends on the quality of the batte...

Страница 34: ...work together to support two phase equipment One units support two phase The supported maximum output power is 15KW 15KVA and one phase can be up to 7 5KW 7 5KVA 2 Package Contents In parallel kit yo...

Страница 35: ...ll cause inverter fault in error code 72 CAUTION Please install the breaker at the battery and AC input side This will ensure the inverter can be securely disconnected during maintenance and fully pro...

Страница 36: ...1 Parallel Operation in Single phase Two inverters in parallel Power Connection Load L N L N L1 L2 L1 L2 Communication Connection Three inverters in parallel Power Connection Load L N L N L1L2 L1L2 L...

Страница 37: ...35 Communication Connection 4 2 Support 2 phase equipment Two inverters in parallel Line to Line output voltage is 208V Power Connection Communication Connection...

Страница 38: ...Two inverters in parallel Line to Line output voltage is 240V Power Connection Communication Connection Three inverters in parallel Line to Line output voltage is 208V Power Connection Load L1 L2 L1 L...

Страница 39: ...37 Communication Connection Three inverters in parallel Line to Line output voltage is 240V Power Connection Load L1 L2 N L1 L2 N Communication Connection...

Страница 40: ...nection WARNING Do NOT connect the current sharing cables between the inverters in different phases Otherwise it may damage the inverters NOTE For parallel model operation please refer to LCD program...

Страница 41: ...Parallel ID Setting It s necessary to set up parallel ID for each inverter 1 2 3 4 Parallel ID OFF OFF OFF 0 ON OFF OFF 1 OFF ON OFF 2 ON ON OFF 3 OFF OFF ON 4 ON OFF ON 5 OFF ON ON 6 ON ON ON 7 Not...

Страница 42: ...program 28 for the inverters connected to L1 phase 3P2 in program 28 for the inverters connected to L2 phase and 3P3 in program 28 for the inverters connected to L3 phase Be sure to connect shared cu...

Страница 43: ...ters When ALL is selected parallel or 3 phase system will continue working according to rule of solar first setting only when all of inverters are connected to PV modules For example two units are con...

Страница 44: ...more fault alarm the parallel system is completely installed Step 6 Please switch on all breakers of Line wires in load side This system will start to provide power to the load Parallel in split phase...

Страница 45: ...hase unit Step 4 Switch on all AC breakers of Line wires in AC input If AC connection is detected and three phases are matched with unit setting they will work normally Otherwise the AC icon will flas...

Страница 46: ...inverter is not the same 1 Make sure all inverters share the same groups of batteries together 2 Remove all loads and disconnect AC input and PV input Then check battery voltage of all inverters If t...