45
NOTE:
“1” is upper position and “0” is bottom position.
Dip 1
Dip 2 Dip 3 Dip 4 Group address
1: RS485
baud
rate=9600
Restart to
take effect
0
0
0
Single group only. It’s necessary to set up master battery with this
setting and slave batteries are unrestricted.
1
0
0
Multiple group condition. It’s necessary to set up master battery on the
first group with this setting and slave batteries are unrestricted.
0
1
0
Multiple group condition. It’s necessary to set up master battery on the
second group with this setting and slave batteries are unrestricted.
1
1
0
Multiple group condition. It’s necessary to set up master battery on the
third group with this setting and slave batteries are unrestricted.
0
0
1
Multiple group condition. It’s necessary to set up master battery on the
forth group with this setting and slave batteries are unrestricted.
1
0
1
Multiple group condition. It’s necessary to set up master battery on the
fifth group with this setting and slave batteries are unrestricted.
NOTE:
The maximum groups of lithium battery is 5 and for maximum number for each group, please check
with battery manufacturer.
4.
Installation and Operation
PYLONTECH
After configuration, please install LCD panel with inverter and Lithium battery with the following steps.
Step 1. Use custom-made RJ45 cable to connect inverter and Lithium battery.
Note for parallel system:
1.
Only support common battery installation.
2.
Use custom-made RJ45 cable to connect any inverter (no need to connect to a specific inverter) and
Lithium battery.
Simply set this inverter battery type to “PYL” in LCD program 5. Others should be “USE”.
Step 2. Switch on Lithium battery.
Step 3. Press more than three seconds to start Lithium battery, power output ready.