![opti-solar SC MPPT series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/opti-solar/sc-mppt-series/sc-mppt-series_user-manual_1641288021.webp)
19
8.3 Technical data of SC-40MPPT
Item
SC-40MPPT
Battery Parameters
Max Charging Current
40A
System Voltage
24V/48V automatical recognization
MPPT Charging Voltage
<29.0/58.0V@25'C
Boost Voltage
29.0/58.0V @25
℃
Equalization Voltage
29.6/59.2V @25
℃(
Liquid, AGM)
Float Voltage
27.4/54.8V @25
℃
Low Volt. Disconnect
21.6-23.6V/43.2-47.2V, S0C1-5(default: 22.4/44.8V)
Reconnect Voltage
23.2-25.6V/46.4-51.2V (default: 24.0
/
48.0V
﹜
Overcharge Protect
31.0/62.0V
Max volt on Bat. terminal 65V
Temp. Compensation
-4.17mV/K per cell (Boost, Equalization),
-3.33mV/K per cell (Float)
Battery Type
Gel, AGM, Liquid (default: Gel)
Panel Parameters
Max volt on PV terminal
150V
﹛-
20
℃)
,
138V(25
℃)
Max input power
1000/2000W
Dusk/Dawn detect volt
16.0/32.0V
MPPT tracking range
(Battery V 1.0V) ~Voc*0.9
Load
Output Current
30A
Work mode
Standard, D2D, Street lamp, User-defined mode
System Parameters
Max tracking efficiency
>
99.9%
Max charge conversion
98.7%
Dimensions(mm)
189 * 255 * 89
Weight 2.5Kg
Self consumption
8mA
Communication RS485(RJ11
interface)
Grounding Common
Negative
Power terminals
6AWG(16mm
²
)
Ambient temperature
-20 ~ + 55
℃
Storage temperature
-25 ~ + 80
℃
Ambient humidity
0 ~100%RH
Protection degree
IP32
Max Altitude
4000m
*1. Voc means the open circuit voltage of the solar panel.
*2. Around oblique line value separately on behalf of 24V and 48V system's value.