opti-solar SC MPPT series Скачать руководство пользователя страница 1

 

 

 
 
 

 

 

 

Solar Charger Controller   

SC-20/40 MPPT 

 
 
 
 
 

 
 
 
 
 

 

Version: 1.1 

User Manual 

Содержание SC MPPT series

Страница 1: ...Solar Charger Controller SC 20 40 MPPT Version 1 1 User Manual...

Страница 2: ...8 5 Installation 9 5 1 Installation Notes 9 5 2 Mounting Location Requirements 9 5 3 Wiring Specifications 10 5 4 Connection 10 5 5 Grounding 6 Operarion 12 6 1 1 Status Description 6 1 2 The interfac...

Страница 3: ...Please take care when meeting these symbols WARNING Indicates a potentially dangerous condition Use extreme caution when performing this task CAUTION Indicates a critical procedure for safe and proper...

Страница 4: ...under the rated charging current Multiple load control modes Standard Dusk to Dawn Timer and User defined mode Two USB interfaces EU Series Based RS 485 standard Modbus protocol to maximize their com...

Страница 5: ...or example the battery voltage may range from 10 8 15 Vdc but the module s Vmp is typically around 16 or 17V Because traditional controllers do not always operate at the Vmp of the solar array energy...

Страница 6: ...tly at the same time The purpose of Float stage is to offset the power consumption caused by self consumption and small loads in the whole system while maintaining full battery storage capacity In Flo...

Страница 7: ...5 3 1 The dimensions of SC 20MPPT 64...

Страница 8: ...6 3 2 The dimensions of SC 40MPPT...

Страница 9: ...gs and operating status system parameters Key MENU OK Set and view the operating parameters RJ11 interface Connecting monitoring devices Temperature Sensor Port Collect temperature information Tempera...

Страница 10: ...ture of the controller is 25 C and the temperature compensation is not carried out when charging Heat Sink dissipate controller heat Plastic Case Internal protection LCD Display settings and operating...

Страница 11: ...e batteries 7 Be very careful when working with batteries Wear eye protection Have fresh water available to wash and clean any contact with battery acid 8 Avoid touching or short circuiting wires or t...

Страница 12: ...ay and the controller or between the controller and the battery larger wires can be used to reduce the voltage drop and improve performance 5 4 Connection We strongly recommend connecting a fuse direc...

Страница 13: ...e battery voltage should between 20V 30V else if the system is A8V the battery voltage should between 40V 60V If the polarity is correct the LCD on the controller will begin to show 2nd step Connect t...

Страница 14: ...12 6 Operation 6 1 LCD Display 6 1 1 Status Description PV array charge ampere hours and load ampere hours are off after power failure...

Страница 15: ...13 6 1 2 The interface automatically Cycles 6 1 3 Press OK to browse the interface...

Страница 16: ...B interface MT EU series have two USB interfaces maximum output of single USB is 5V 1 5A maximum output of two USB is 5V 2A for charging mobile phones and other smart devices The USB stops output only...

Страница 17: ...the controller is working in the street lamp mode press the MENU key for 3 seconds to turn on the load Press the MENU key again or the load turns off automatically after 1 minute If the controller is...

Страница 18: ...y Reverse Polarity Fully protection against battery reverse polarity no damage to the controller Correct the connection to start normal operation Battery Over Voltage If there are other energy sources...

Страница 19: ...nections Check and confirm that LCD is consistent with required Pay attention to any troubleshooting or error indication Take corrective action if necessary Confirm that all the system components are...

Страница 20: ...attery Type Gel AGM Liquid default Gel Panel Parameters Max volt on PV terminal 100V 20 90V 25 Max input power 260 520W Dusk Dawn detect volt 8 0 16 0V MPPT tracking range Battery Voltage 1 0V Voc 0 9...

Страница 21: ...ry Type Gel AGM Liquid default Gel Panel Parameters Max volt on PV terminal 150V 20 138V 25 Max input power 1000 2000W Dusk Dawn detect volt 16 0 32 0V MPPT tracking range Battery Voltage 1 0V Voc 0 9...

Отзывы: