background image

10. Technical Data

Page13/13 Pages

10Ah~9990Ah

(

default : 

Programmable), 

300Ah

14.0V/28.0V(25

)

13.0~14.5V/26.0~29.0V

(

default : 13.7V/27.4V

Programmable), 

(25

)

3.0~7.5V/6.0~15.0V

(

default : 3.0V/6.0V

Programmable), 

11.0~12.5V/22.0~25.0V

(

default : 

Programmable), 

11.1V/22.2V

11.8~13.3V/23.6~26.6V(Programable), default : 12.6V/25.2V

20~70%

(

default : 30%

Programmable), 

40~90%

(

default : 50%

Programmable), 

M a x

5

0

5

0  A

55 V

40 V

164*189*47 / 

69

0

g

50mm

²

1

5

mA

-10℃ ~ +60 ℃

IP32

-25℃ ~ +80 ℃

M a

x 6

0

6

0  A

14.0~15.0V/28.0~30.0V

(

default :  4.

Programmable), 

1

5V/29.0V(25

)

14.0~15.5V/28.0~31.0V

(

default :  4.

(25

)

Programmable), 

1

8V/29.6V

00:00

~

02:00(Interval 5min, Programmable), default : 00:00

M a x 2 0

M a

x

3

0

M a x

4

0

4

0  A

3

0  A

2 0  A

127*189*47 / 550

g

25

mm²

13.8mA

Mode

System voltage

Max solar

 

or load current

Fast voltage

Boost voltage

Equal voltage

Float voltage

Day/Night threshold

Nominal capacity

Battery type

Temperature compensation

Load disconnect
voltage

Load reconnect
voltage

Soc

Voltage

Soc

Voltage

Load mode

Light on delay

Light off delay

Night time 1

Night time 2

LVD protection mode

Max solar voltage

Max battery voltage

Dimensions/Weiht

Max wire size

Max power consumption

Storage temperature

Case protection

Relative humidity

10%~90% Non-condensation

00:00

~

09:00(Interval 15min, Programmable), default : 00:00

00:00

~

09:00(Interval 15min, Programmable)

default : 00:00

00:00

~

02:00(Interval 5min, Programmable)

default : 00:00

Auto, Standard, Timer(default : Auto)

Soc, Voltage(default : Soc)

-4

.

17

 

mV/K per cell (Boost and Equal charge),

-3.33

 

mV/K per cell (Float charge)

Liquid, Gel( default : Liquid)

1

2V/24V

 

automatic recognition

Temperature Range 
during operation

Содержание SC-30MAX

Страница 1: ...Solar Charge Controller 30A 40A 50A 60A User Manual SC Max series...

Страница 2: ...in Menu 7 3 Menu Conf System module settings 7 4 Menu Prog System parameter settings 7 5 Menu Load Load mode settings 7 6 Menu Logg Inquiry of internal data logger 7 7 Example of configuration 7 7 1 B...

Страница 3: ...es store a large amount of energy never short circuit a battery under all circumstances We strongly recommend connecting a fuse directly to the battery to protect any short circuit at the battery wiri...

Страница 4: ...able openings facing downwards 5 4 Connection We strongly recommend connecting a fuse directly to the battery to protect any short circuit at the battery wiring Solar PV modules create current wheneve...

Страница 5: ...s 12V please make sure that the battery voltage is within 10V 16V else if the system is 24V the battery voltage should between 20V 30V If the polarity is correct the LCD screen on the controller will...

Страница 6: ...nical reasons it is easier to indicate a two digit number BAT shows the battery s actual voltage IN is the sum of the charging currents flowing into the battery OUT is the sum of discharge currents fl...

Страница 7: ...priate information You can use the keys to select sub menu and press the OK button to enter the sub menu After entering the sub menu press to change the value After setting press the OK button to save...

Страница 8: ...System parameter settings In this menu you can set the charging parameters Day Nigh threshold LVD and LVR data Press to enter the menu Note We have tried to insure that the values are limited within r...

Страница 9: ...ight conditions and the solar array used Possibilities for programming 3 0 7 5V 6 0V 15 0V Default 3 0V 6 0V Low voltage disconnect settings Press the OK button to enter the menu press to change the v...

Страница 10: ...solar charge controller can control night lighting automatically by evaluating the density of outside light with the help of the solar PV module array Depending on the PV array alignment or shading it...

Страница 11: ...time you can view the accumulated value in and out of the system since the controller installed Inquiry of internal data logger From this menu window you can read the actual daily value of amp hours i...

Страница 12: ...n enter the Factory adjust window The instruction to press the MENU key plus the OK key appears immediately Only by pressing both of these keys simultaneously will the factory pre set configurations b...

Страница 13: ...wired in parallel In order to prevent fuses from blowing in the case of high currents over a short period of time a high value has been selected Before the fuses blow the electronic safety fuse should...

Страница 14: ...to reduce further heat generation the loads are disconnected automatically As soon as the solar charge controller has cooled down normal operation will resume Check the ventilation at the back heat si...

Страница 15: ...3 8mA Mode System voltage Max solar or load current Fast voltage Boost voltage Equal voltage Float voltage Day Night threshold Nominal capacity Battery type Temperature compensation Load disconnect vo...

Отзывы: