-11-
These units are designed to detect an intruder and activate
an alarm control panel. Being only a part of a complete
system, we cannot accept responsibility for any damages
or other consequences resulting from an intrusion.
These products conform to the EMC Directive 2004/108/EC.
Specifications and design are subject to change without prior notice.
* The value is based on the condition that it is used within the
ambient temperature range of 20 to 25°C. (LSH-20 x2 pcs)
** Using batteries other than those recommended may shorten the battery life.
TROUBLESHOOTING
6
SPECIFICATIONS
8
NOTE
Model
SL-350QFR
SL-350QNR
Maximum detection range
100 m/350 ft.
Maximum arrival distance
1000 m/3500 ft.
Detection method
Quad infrared beam interruption detection
Selectable beam frequency
4 channels
Interruption time
Variable between 50/100/250/500 ms
(4 steps)
Power source
Recommend: 3.6 V, 13.0 Ah
LSH20 lithium batteries manufactured by SAFT
Operating range: 3.2 V - 4.0 V litium batteries
Transmitter: 2 or 4 units, Receiver: 2 or 4 units
Current draw
745 μA
Transmitter: 420 μA + Receiver: 325 μA
(at 25°C, 3.6 VDC)
Battery life
Transmitter: Approx. 4 years
Receiver:
Approx. 5 years
Alarm output
Form C-Solid State Switch: 3.6 VDC, 0.01 A
Alarm period
2 sec (±1) (Nominal)
D.Q output
Form C-Solid State Switch: 3.6 VDC, 0.01 A
(Receiver only)
Low battery
output
N.C. (Solid State Switch): 3.6 VDC, 0.01 A
Tamper output
(cover, back box,
main unit)
N.C. (Mechanical Switch): 3.6 VDC, 0.01 A
Opens when cover, main unit
or back box is removed.
Alarm indicator
(Receiver)
Alarm: ON
Light receiving: OFF
Level indicator
(Receiver)
Not Light receiving: OFF
Light receiving: Blinking or OFF
Power indicator
(Transmitter)
Power ON: ON
Power OFF: OFF
Low battery indicator
Voltage reduction: Blinking
Operating temperature
-20°C - +60°C (-40°F - 140°F)
Operating humidity
95 % (max.)
Alignment angle
±90° Horizontal, ±10° Vertical
Dimension
H х W х D mm (inch):
452 (17.9) x 83 (3.3) x 138 (5.4)
Weight
3300 g (Total weight of Trans
Receiver, excluding accessories)
International protection
IP65
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
LEDs are not
illuminated.
(transmitter/receiver)
Reversed battery polarity.
Check the battery polarity.
Low battery indicator
blinks even though
the battery has
been inserted.
(transmitter/receiver)
Reversed battery polarity.
Check the battery polarity.
Alarm is not
output.
Reflection from the floor or wall.
Beam has not been blocked.
Block all four beams.
Alarm is kept
output.
Channels of transmitter
and receiver are different.
Set the same channel to
both transmitter and receiver.
Multiple photoelectric
detector for long distance
or beam stacking applications.
Set channels 1-3 or 2-4 or
1-4.
Optical alignment was not
performed properly.
See “4-2 OPTICAL
ALIGNMENT” on Page 9.
Batteries are going
flat too quickly.
performed properly.
Set the cover or tamper
lock plate properly.
Frost, snow or
heavy rain causes
false alarm.
Optical alignment not
optimized.
See “4-2 OPTICAL
ALIGNMENT” on Page 9
and make realignment.
Improper output
The wiring is incorrect.
Make correct wiring.
Wall tamper does
not activate.
Screws between the
chassis and the back box
are loose.
Tighten screws completely.
The waterproof packing on
back box is misplaced.
Remove chassis from the
back box and align the
waterproof packing onto
the chassis.
Align beams away from the
floor or wall.
Tamper button has not
6-1 TROUBLESHOOTING
8-1 SPECIFICATIONS
Unit: mm (inch)
DIMENSIONS
7
7-1 DIMENSIONS
452 (17.8)
138 (5.4)
83 (3.3)
83.5 (3.28)
(W
ALL)
222 (8.7) (POLE1)
265 (10.4) (POLE2)
390 (15.4) (W
ALL)
Output