An example of IP address settings
IP Address
Subnet Mask
:
192.168.0.1
:
255.255.255.0
The default settings of PIE-1 are as follows.
IP Address:
192.168.0.126
Subnet Mask:
255.255.255.0
Defoult Gateway:
0.0.0.0
(1) Before using PIE-1, set the IP addresses of PIE-1
and the computer in the following procedure.
1.
Set the local area connection.
7.
Click “Overview”
button. Confirm the settings in
the Overview screen.
6.
After changing settings. Click “Save Config”
button.
Download the detailed instructions at our site.
(http://www.optex.co.jp/e/redwall/download/index.html)
If you forget the IP address you have set, reset it to
obtain the default IP address in the following procedure.
2.
Using Internet Explorer, access the site below.
(http://192.168.0.126/)
3.
Enter the user ID and the password below.
User ID: PIE-1
Password: OPTEX
4.
Change the IP address if necessary.
5.
Select the detector you have connected.
(2) Confirm the output of the Event Code, and set
VMS/NVR.
(3) After setting VMS/NVR, conduct a walk test.
AFTER INSTALLATION
3
RESETTING
4
1.
Pull off the cable connected to the Ethernet
connector for PoE.
PIE-1 turns off.
2.
While pressing the
RESET button,
connect the cable to
the Ethernet
connector for PoE
again. PIE-1 turns on.
3.
Keep pressing the RESET button until the
green and yellow LEDs both go off. (They go off
within ten seconds.)
4.
Release the RESET button. The software
restarts, and PIE-1 obtains the default IP
address.
Alarm 6-pin cable
SIP-404, 4010, 3020
SIP-5030, 404/5, 4010/5, 3020/5
SIP-100
Model name
Orange pair Yellow pair Green pair Blue pair Purple pair
Red
Black
Far
-
-
-
Near
Creep
Tamper
Trouble
(+)
(-)
Alarm
Creep
Tamper
Trouble
(+)
(-)
Alarm
Tamper
Trouble
(+)
(-)
Alarm 4-pin cable Power 2-pin cable
PIE-1 CONNECTION TABLE FOR SIP SERIES
Be sure to insulate the cables you are not using.
Caution