Optex REDBEAM Series Скачать руководство пользователя страница 1

-1-

• Be sure to thoroughly read the instruction manuals of each product before performing wiring.
• The SIP mounting plate for Gang Box, Gasket sheet for Gang Box, and No. 6-32 UNC screws (5/8 inch) (6 pcs) that are described in PIE-1 

Manual are not included in this product as they are not required.

• Up to two detectors can be connected to a PIE-1. (Wire size: at least AWG26 (0.13 mm

2

), wire length: 2.5 m (8.2 ft.) max.)

BEFORE YOUR OPERATION

1

ASSEMBLY

2

No.59-1968-0

Detection range

RBM-60QN-IP
RBM-100QN-IP
RBM-200QN-IP

MODEL

 60m/200ft.

350ft.

0

0

2

m/650ft.

WIRING DIAGRAM

NETWORK PHOTOELECTRIC DETECTOR

NETWORK PHOTOELECTRIC DETECTOR

REDBEAM series

REDBEAM series

ø 21mm (0.84 inch) hole diameter

(2) Connect the couduit to the knockout 

hole of the back box.

(1) Open the knockout hole (upper or lower)

of the back box.

Step 1

Step 2

Pass the LAN cable 
or the external cable 
through the grooves 
as shown below.

Step 1

Refer to

Step 4

Caution

Be sure to connect the connector after 
cutting all the unnecessary wires.

100m/

Back box

PIE-1

Sponge

Chassis

Main unit

Cover

(1) Mount the sponge.
(2) Mount the chassis.
(3) Mount the main unit.
(4) Wire the sensor.
(5) Connect the alarm 6-pin and power 2-pin cables.
(6) Perform optical adjustment.
(7) Mount the cover.

(2)

(1)

(3)

(4)

Step 3

(1) Plug the alarm 10-pin cable to PIE-1.
(2) Plug the power 2-pin cable to PIE-1. 

Use the 24VDC connector.

(3) Set the Selector switch of PIE-1.
(4) Plug the CAT5e cable to the 

Ethernet connector for PoE of PIE-1.

(5) Place PIE-1 into the back box.

Upper

Lower

Note >>

Run the cables so that 
they are not pinched 
between the chassis 
and back box.

Banding band

Wiring notch