![Optex REDBEAM Series Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/optex/redbeam-series/redbeam-series_wiring-diagram_1641032001.webp)
-1-
• Be sure to thoroughly read the instruction manuals of each product before performing wiring.
• The SIP mounting plate for Gang Box, Gasket sheet for Gang Box, and No. 6-32 UNC screws (5/8 inch) (6 pcs) that are described in PIE-1
Manual are not included in this product as they are not required.
• Up to two detectors can be connected to a PIE-1. (Wire size: at least AWG26 (0.13 mm
2
), wire length: 2.5 m (8.2 ft.) max.)
BEFORE YOUR OPERATION
1
ASSEMBLY
2
No.59-1968-0
Detection range
RBM-60QN-IP
RBM-100QN-IP
RBM-200QN-IP
MODEL
60m/200ft.
350ft.
0
0
2
m/650ft.
WIRING DIAGRAM
NETWORK PHOTOELECTRIC DETECTOR
NETWORK PHOTOELECTRIC DETECTOR
REDBEAM series
REDBEAM series
™
™
ø 21mm (0.84 inch) hole diameter
(2) Connect the couduit to the knockout
hole of the back box.
(1) Open the knockout hole (upper or lower)
of the back box.
Step 1
Step 2
Pass the LAN cable
or the external cable
through the grooves
as shown below.
Step 1
Refer to
Step 4
Caution
Be sure to connect the connector after
cutting all the unnecessary wires.
100m/
Back box
PIE-1
Sponge
Chassis
Main unit
Cover
(1) Mount the sponge.
(2) Mount the chassis.
(3) Mount the main unit.
(4) Wire the sensor.
(5) Connect the alarm 6-pin and power 2-pin cables.
(6) Perform optical adjustment.
(7) Mount the cover.
(2)
(1)
(3)
(4)
Step 3
(1) Plug the alarm 10-pin cable to PIE-1.
(2) Plug the power 2-pin cable to PIE-1.
Use the 24VDC connector.
(3) Set the Selector switch of PIE-1.
(4) Plug the CAT5e cable to the
Ethernet connector for PoE of PIE-1.
(5) Place PIE-1 into the back box.
Upper
Lower
Note >>
・
Run the cables so that
they are not pinched
between the chassis
and back box.
Banding band
Wiring notch