background image

Light

Blink

OFF

DETECTOR STATUS

Person detected

Warm-up period

PIR detection

MW detection

Power supply abnormality

Anti-Masking 

(OML-DAM)

Detection failure

LED Indications

Red lights

All LED blink

Green lights

Yellow lights

Red blinks

Yellow&green blink

Red&green blink

LED operation

* Specifications and design are subject to change without prior notice.

Model

Detection method

Detector 
standard
Masking 
detection method
PIR Coverage 
[Detection zones]

Power supply

Current 
consumption

Alarm output

Tamper switch

Trouble output

Operating 
temperature
Environmental 
humidity

RF interference

Mounting height

Weight 

Dimensions 
(H×W×D) 

OML-ST

OML-AM

OML-DT

OML-DAM

Passive infrared

Passive infrared & Microwave

prEN50131-2-2

(Grade 2)

prEN50131-2-2

(Grade 3)

prEN50131-2-4

(Grade 2)

prEN50131-2-4

(Grade 3)

AIR type

AIR type

15m × 15m (50ft. × 50ft.) 85° wide [82 zones]

9 - 18VDC

16mA (normal) / 

18mA (max.) at 

12V DC

22mA (normal) / 

23mA (max.) at 

12V DC

19mA (normal) / 
24mA (max.) at 

12V DC

25mA (normal) / 

29mA (max.) at 

12V DC

N.C. 28V DC 0.2A max.

N.C. Opens when cover is removed and when the 

wall tamper switch operates.  28V DC 0.1A max.

N.C. 28V DC 

0.2A max.

N.C. 28V DC 

0.2A max.

-10°C - +50°C (14°F - 122°F)

95% max.

No alarm 30V/m

1.8 - 3.0m

(6 - 10ft.)

1.8 - 2.4m (6 - 8ft.)

180g (6.3oz)

140×70×52.3mm (5.51×2.76×2.06 inches)

OPTEX INCORPORATED (USA)

TEL:+1-909-993-5770
Tech:(800)566-7839 
URL:http://www.optexamerica.com

OPTEX KOREA CO., LTD. (KOREA)

TEL:+82-2-719-5971
URL:http://www.optexkorea.com

OPTEX SECURITY Sp.z   o.o. (POLAND)

TEL:+48-22-598-06-55
URL:http://www.optex.com.pl

OPTEX (DONGGUAN) CO., LTD.
SHENZHEN OFFICE (CHINA)

TEL:+86-755-33302950
URL:http://www.optexchina.com

OPTEX CO., LTD. (JAPAN)

(ISO 9001 Certified by LRQA) (ISO 14001 Certified by JET)

5-8-12 Ogoto Otsu Shiga 520-0101 JAPAN
TEL:+81-77-579-8670   FAX:+81-77-579-8190   URL:http://www.optex.co.jp/e/

OPTEX (EUROPE) LTD. (UK)

TEL:+44-1628-631000
URL:http://www.optexeurope.com

OPTEX SECURITY SAS (FRANCE)

TEL:+33-437-55-50-50
URL:http://www.optex-security.com

WARRANTY

5 year replacement warranty

The OPTiMAL series is designed to detect movement of an 
intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept 
responsibility for any damages or other consequences resulting 
from an intrusion. Due to our policy of continuous improvement 
Optex reserves the right to change specification without prior 
notice.  
The Warranty period is from the date of purchase.

SPECIFICATIONS

9

The following statement will be provided with the equipment as 
required by Article 6.3 of the R&TTE Directive, 1999/5/EC.

The Optex OPTiMAL series are in conformity with all essential 
requirements of the R&TTE Directive (1999/5/EC). This equipment 
has been assessed to the following standards:
EN 300 440: 2004
EN 50130-4: 2004 including amendment 2:  2003
EN 60950: 2006

This product is marked with 

 

 which signifies 

conformity with Class II product requirements specified in the 
R&TTE Directive.

The following table indicates the areas of intended use of the 
equipment and any known restrictions. For countries not included 
in this list, please consult the responsible Spectrum Management 
Agency.

NOTE

OPTION

LED FUNCTIONS

8

Country of intended use

Austria

Belgium

Denmark

Finland

France

Greece

Ireland

Italy

Restrictions

9.900GHz

10.525GHz

10.525GHz

9.900GHz

9.900GHz

10.525GHz

10.687GHz

9.900GHz

Country of intended use

Luxembourg

The Netherlands

Spain

Sweden

United Kingdom

Other non-EU: Iceland

Norway

Switzerland

Restrictions

10.525GHz

10.525GHz

10.525GHz

10.525GHz

10.687GHz

10.525GHz

10.525GHz

9.900GHz

CL-80N : LONG RANGE LENS (OML-ST only)
FA-1W :  Wall Mount Bracket : adjustable ±45° (Horizontally), 
 

0-20° (Vertically downwards)  

FA-3 :   Compact Wall & Ceiling Bracket : adjustable ±45°
 

(Horizontally), 0-10° (Vertically downwards)

FCC Notice:

This equipment has been tested and found to comply with the 
limits for a field disturbance sensor, pursuant to Part 15 of the 
FCC Rules. The user is cautioned that changes or modifications 
not expressly approved by OPTEX could void the user’s 
authority to operate this equipment.

EN50131-1 Grades and Environmental Class:

All models are Environmental Class 2
The OML-ST and OML-DT are Security Grade 2
The OML-AM, OML-DTP and OML-DAM are Security Grade 3

Yellow Red Green

DETECTOR STATUS

Person detected

Warm-up period

Power supply abnormality

Anti-Masking

Detection failure

LED Indications

Red lights

Yellow&red blink

Red blinks

Yellow blinks

Red blinks

LED operation

DETECTOR STATUS

Person detected

Warm-up period

Power supply abnormality

Detection failure

LED Indications

Red lights

Red blinks

Red blinks

Red blinks

LED operation

OML-ST

OML-AM

OML-DT

OML-DAM

OML-ST

OML-AM

OML-DT

OML-DAM

OML-ST

OML-AM

OML-DT

OML-DAM

Отзывы: