ADJUSTMENTS

When using more than two sensors close to each other, set a different

frequency for each sensor by dipswitches 5 and 6. 

3-3.Setting the frequency

3-5.Setting the door cancel function

3-7.Setting the automatic infinite presence detection

Dipswitch settings

3-1.Setting the sensitivity

3-2.Setting the presence detection timer

Presence detection timer can be selected by dipswitch 3 and 4.

To enable the presence detection, do not enter the detection area for 10 seconds after setting the timer.

1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)

2. Do not wash the sensor with water.

3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.

4. When the operation indicator is twice geen blinking, contact your installer or service engineer.

5. Always contact your installer or service engineer when changing the settings.

6. Do not paint the detection window.

WARNING

1. When turning the power on, always walk-test the detection area to ensure the proper operation.

2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)

Set the rows with dipswitches 7 and 8.

3-4.Setting the row adjustment

NOTE

NOTE

When dipswitch 9 is "ON" the sensor is less influenced by the door movement, i.e. 

caused by wind.

If the sensor does not detect for 10 sec., the 1st row will be disabled when door cancel 

function is“ON”.

(The 1st row will be enabled again when there is detection at other rows.)

3

9

9

OFF

ON

6

5

Setting1

6

5

Setting2

6

5

Setting3

6

5

Setting4

2

1

Low

2

1

Middle

2

1

High

2

1

S-High

8

7

5rows

8

7

4rows

8

7

3rows

8

7

2rows

INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS 

3-6.Setting the ON delay 2 sec.

10

10

OFF

  ON

11

11

OFF

  ON

13

13

N.O.

  N.C.

  Activation output

14

14

N.O

  N.C

Safety output

To avoid unnecessary openings due to passing objects/persons set dipswitch 10 "ON".

The sensor only activates when a person or object stays in the detection area for more 

then 2 seconds.

3-8.Setting the presence area

3-9.Setting the outputs

1,2   : Sensitivity

3,4   : Presence detection timer

5,6   : Frequency

7,8   : Row adjustment

9      : Door cancel function

10    : ON delay

11    :Automatic infinite

           presence detection   

12     : Presence area

13     : Activation output

14     : Safety output

15     : Simultaneous output

16     : N/A

8

1 2 3 4 5 6 7

16

9 101112131415

Dipswitches

Check the operation according to the chart below.

CHECKING

Status

Image

Green

Red

Entry

Outside of 

detection 

area 

Outside of 

detection 

area 

Entry into

3rd to 5th row 

Entry into 

2nd row 

Entry into 

1st row

Orange

Stand-by

Green

Stand-by

Operation indicator

Motion / Presence

detection active

Power OFF

-

None

Activation

output

N.O.

Safety

output

Activation

output

Safety

output

Recommended sensitivity setting in accordance with the following 

mounting height.

When dipswitch 11 is set to “ON”  the automatic infinite presence detection has priority over this function.

NOTE

OPTEX Technologies Inc.

Corporate Headquarters

North and South America Subsidiary

3882 Del Amo Blvd., Suite 604 Torrance, CA 90503 U.S.A.

TOLL-FREE: +1-800-877-6656     FAX.: +1(310)214-8655 

WEBSITE: www.optextechnologies.com

East coast office 

OPTEX Co.,LTD.

OPTEX Technologies B.V.

Manufacturer

European Subsidiary

5-8-12 Ogoto Otsu 520-0101, Japan

TEL.: +81(0)77-579-8700    FAX.: +81(0)77-579-7030

WEBSITE: www.optex.co.jp/as/eng/index.html

Henricuskade 17, 2497 NB The Hague,The Netherlands

TEL.: +31(0)70-419-4100    FAX.: +31(0)70-317-7321

E-MAIL: [email protected]       WEBSITE: www.optex.eu

8510 McAlpines Park Drive, Suite 108 Charlotte,

NC 28211 U.S.A.

TOLL-FREE.: +1-800-877-6656    FAX.: +1(704)365-0818 

WEBSITE: www.optextechnologies.com

 The output timing from “Activation output” and "Safety output" can be changed

 by dipswitch 15. 

 With dipswitch 15 set to “ON” the output timing will be the same.

 With dipswitch 15 set to “OFF” the output timing will be different.

 See 

CHECKING

.

Wrong wiring or connection failure.

Check the wires and connector.

Door Operation Operation

indicator

Possible cause 

Possible countermeasures

None

Wrong power supply voltage.

Set to the stated voltage.

Wrong wiring or connection failure.

Door opens

when no one

is in the 

detection area.

(Ghosting)

Unstable

Door remains

open

Presence timer is “     ” and

sudden change in the detection area

happened.

Check  

ADJUSTMENTS

 

3-2 & 3-7

.

If the problem still persists, hard-reset the

sensor.(Turn the power OFF and ON again.)

Check the wires and connector.

Door does not

open when a 

person enters 

the detection 

area.

Unstable

Wrong detection area positioning.

Check  

DETECTION AREA

 & 

ADJUSTMENTS

Sensitivity is too low.

Set the sensitivity higher.

Short presence detection timer.

Set the presence detection timer longer.

Proper

Dirty detection window.

Wipe the detection window with a damp cloth.

(Do not use any cleaner or solvent.)

TROUBLESHOOTING

Adjust the detection area to "Deep" (Outside).

Water drops on the detection window.

Use the rain-cover (Separately available).

Or install the sensor in a place keeping the water

-drops off.

The detection area overlaps

with that of another sensor.

The detection area overlaps

with the door / header.

Check 

ADJUSTMENTS 3-3

.

Sensitivity is too high.

Set the sensitivity lower.

Check 

ADJUSTMENTS 3-1

.

Wrong (Safety/Activation) output setting.

Check 

ADJUSTMENTS 3-9

.

Green

Both ON delay and door cancel function 

are “ON”.

Set either function to “OFF”

Check 

ADJUSTMENTS 3-5 & 3-6

.

Wrong (Safety/Activation) output setting.

Check 

ADJUSTMENTS 3-9

.

The automatic infinite presence 

detection is “ON” and the objects or 

people enter more than two spot areas.

Remove the objects. 

Or check  

ADJUSTMENTS

 

3-7

.

Wrong (Safety/Activation) output setting.

Check 

ADJUSTMENTS 3-9

.

Green

Orange

Wrong wiring.

Check the wires and connector.

Twice

Green

blinking

Signal saturation

Output relay(s) is reaching the end of 

its life cycle.

The detection area overlaps with

the door / header. 

Adjust the detection area to "Deep" (Outside).

Slow

Green

blinking

Remove highly reflecting objects from the

detection area.Change the area angle. 

Replace the sensor.

Proper

WARNING

Risk of getting caught.

Please do not set ON delay 2sec. to “ON” when door cancel function is “ON”.

If both are "ON" , the sensor does not output signal unless it detects a person 

or object more than 2sec and 1st row is inactive. 

If the person or object enter the fist row, the sensor does not detect and door

never opens.

WARNING

Risk of getting caught.

Alarm display

Refer to the 

TROUBLESHOOTING

 below when the following appears.

Life cycle notification

Twice green blinking

Signal Saturation

Slow green blinking

Status

Operation indicator 

2sec.

60sec. 10min.

4

3

4

3

4

3

4

3

When people or objects enter more than 2 spot areas, this function automatically sets the presence 

detection timer to infinity to increase safety and avoid unwanted door opening due to sudden change

 in floor condition.

NOTE

Adjust the sensitivity to suit each installation site.

When "2rows" is selected, the activation output 

is disabled.

NOTE

Simultaneous

output

Simultaneous

output

  ON

15

OFF

15

13

N.C.

13

N.O.

14

N.C.

14

N.O.

13

N.C.

13

N.O.

14

N.C.

14

12

12

1st & 2nd 1st to 5th

With dipswitch 12 “1st & 2nd” , presence detection timer for 1st & 2nd rows belong to 

dipswitch 3 and 4.  Presence detection timer for 3th to 5th row automatically becomes 2 sec..

With dipswitch 12 “1st to 5th” , presence detection timer will be same as all detection area, 

set by combining dipswitch 3 and 4.

2

Area width adjustment

When adjusting the width adjustment screws, make sure to turn until they click otherwise proper 

operation may not be obtained.

            cannot be eliminated separately, neither can              .

NOTE

1 2 3

10 11 12

Width adjustment 

screws (Left)

1st to 3rd rows

Narrow

Wide

Eliminated

Eliminated

Eliminated

Eliminated

1 2 3

10 11 12

Width adjustment 

screws (Right)

4th and 5th rows 

Narrow

Wide

Eliminated

Eliminated Eliminated

Eliminated

1 2 3

10 11 12

Front view

2.0

(6’7”)

3.0

(9’10”)

4.0

(13’2”)

4.5

(14’9”)

0

1.0

(3’3”)

1.0

(3’3”)

2.0

(6’7”)

2.0

(6’7”)

3.0

(9’10”)

3.0

(9’10”)

[mm(feet,inch)]

12

1 2 3 4 5 6 7 8 9 10 11

: 2.5m(8’2”) to 3.5m(11’6”)

: 3.0m(9’10”) to 4.0m(13’2”)

: 3.5m(11’6”) to 4.5m(14’9”)

: 4.0m(13’2”) to 4.5m(14’9”)

L (Low) 

M (Middle)

H (High)

S-High(Super high)

  ON

OFF

15

15

Simultaneous

output

The activation and safety outputs can be selected separately 

( N.C. or N.O. by dipswitch 13 and 14 )

With this fuction, 1st row is disabled if there are no ditection for 10sec.

If a person or vehicle enter the first row without any detection in other rows 

(e.g. enter from the other side), it might cause an accident.

All manuals and user guides at all-guides.com

Отзывы: