![Optex OA-4500S Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/optex/oa-4500s/oa-4500s_installation-manual_1640831002.webp)
ADJUSTMENTS
When using more than two sensors close to each other, set a different
frequency for each sensor by dipswitches 5 and 6.
3-3.Setting the frequency
3-5.Setting the door cancel function
3-7.Setting the automatic infinite presence detection
Dipswitch settings
3-1.Setting the sensitivity
3-2.Setting the presence detection timer
Presence detection timer can be selected by dipswitch 3 and 4.
To enable the presence detection, do not enter the detection area for 10 seconds after setting the timer.
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.(Do not use any cleaner / solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. When the operation indicator is twice geen blinking, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
WARNING
1. When turning the power on, always walk-test the detection area to ensure the proper operation.
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
Set the rows with dipswitches 7 and 8.
3-4.Setting the row adjustment
NOTE
NOTE
When dipswitch 9 is "ON" the sensor is less influenced by the door movement, i.e.
caused by wind.
If the sensor does not detect for 10 sec., the 1st row will be disabled when door cancel
function is“ON”.
(The 1st row will be enabled again when there is detection at other rows.)
3
9
9
OFF
ON
6
5
Setting1
6
5
Setting2
6
5
Setting3
6
5
Setting4
2
1
Low
2
1
Middle
2
1
High
2
1
S-High
8
7
5rows
8
7
4rows
8
7
3rows
8
7
2rows
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
3-6.Setting the ON delay 2 sec.
10
10
OFF
ON
11
11
OFF
ON
13
13
N.O.
N.C.
Activation output
14
14
N.O
N.C
Safety output
To avoid unnecessary openings due to passing objects/persons set dipswitch 10 "ON".
The sensor only activates when a person or object stays in the detection area for more
then 2 seconds.
3-8.Setting the presence area
3-9.Setting the outputs
1,2 : Sensitivity
3,4 : Presence detection timer
5,6 : Frequency
7,8 : Row adjustment
9 : Door cancel function
10 : ON delay
11 :Automatic infinite
presence detection
12 : Presence area
13 : Activation output
14 : Safety output
15 : Simultaneous output
16 : N/A
8
1 2 3 4 5 6 7
16
9 101112131415
Dipswitches
Check the operation according to the chart below.
CHECKING
Status
Image
Green
Red
Entry
Outside of
detection
area
Outside of
detection
area
Entry into
3rd to 5th row
Entry into
2nd row
Entry into
1st row
Orange
Stand-by
Green
Stand-by
Operation indicator
Motion / Presence
detection active
Power OFF
-
None
Activation
output
N.O.
Safety
output
Activation
output
Safety
output
Recommended sensitivity setting in accordance with the following
mounting height.
When dipswitch 11 is set to “ON” the automatic infinite presence detection has priority over this function.
NOTE
OPTEX Technologies Inc.
Corporate Headquarters
North and South America Subsidiary
3882 Del Amo Blvd., Suite 604 Torrance, CA 90503 U.S.A.
TOLL-FREE: +1-800-877-6656 FAX.: +1(310)214-8655
WEBSITE: www.optextechnologies.com
East coast office
OPTEX Co.,LTD.
OPTEX Technologies B.V.
Manufacturer
European Subsidiary
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77-579-8700 FAX.: +81(0)77-579-7030
WEBSITE: www.optex.co.jp/as/eng/index.html
Henricuskade 17, 2497 NB The Hague,The Netherlands
TEL.: +31(0)70-419-4100 FAX.: +31(0)70-317-7321
E-MAIL: [email protected] WEBSITE: www.optex.eu
8510 McAlpines Park Drive, Suite 108 Charlotte,
NC 28211 U.S.A.
TOLL-FREE.: +1-800-877-6656 FAX.: +1(704)365-0818
WEBSITE: www.optextechnologies.com
The output timing from “Activation output” and "Safety output" can be changed
by dipswitch 15.
With dipswitch 15 set to “ON” the output timing will be the same.
With dipswitch 15 set to “OFF” the output timing will be different.
See
CHECKING
.
Wrong wiring or connection failure.
Check the wires and connector.
Door Operation Operation
indicator
Possible cause
Possible countermeasures
None
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure.
Door opens
when no one
is in the
detection area.
(Ghosting)
Unstable
Door remains
open
Presence timer is “ ” and
sudden change in the detection area
happened.
Check
ADJUSTMENTS
3-2 & 3-7
.
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again.)
Check the wires and connector.
Door does not
open when a
person enters
the detection
area.
Unstable
Wrong detection area positioning.
Check
DETECTION AREA
&
ADJUSTMENTS
Sensitivity is too low.
Set the sensitivity higher.
Short presence detection timer.
Set the presence detection timer longer.
Proper
Dirty detection window.
Wipe the detection window with a damp cloth.
(Do not use any cleaner or solvent.)
TROUBLESHOOTING
Adjust the detection area to "Deep" (Outside).
Water drops on the detection window.
Use the rain-cover (Separately available).
Or install the sensor in a place keeping the water
-drops off.
The detection area overlaps
with that of another sensor.
The detection area overlaps
with the door / header.
Check
ADJUSTMENTS 3-3
.
Sensitivity is too high.
Set the sensitivity lower.
Check
ADJUSTMENTS 3-1
.
Wrong (Safety/Activation) output setting.
Check
ADJUSTMENTS 3-9
.
Green
Both ON delay and door cancel function
are “ON”.
Set either function to “OFF”
Check
ADJUSTMENTS 3-5 & 3-6
.
Wrong (Safety/Activation) output setting.
Check
ADJUSTMENTS 3-9
.
The automatic infinite presence
detection is “ON” and the objects or
people enter more than two spot areas.
Remove the objects.
Or check
ADJUSTMENTS
3-7
.
Wrong (Safety/Activation) output setting.
Check
ADJUSTMENTS 3-9
.
Green
Orange
Wrong wiring.
Check the wires and connector.
Twice
Green
blinking
Signal saturation
Output relay(s) is reaching the end of
its life cycle.
The detection area overlaps with
the door / header.
Adjust the detection area to "Deep" (Outside).
Slow
Green
blinking
Remove highly reflecting objects from the
detection area.Change the area angle.
Replace the sensor.
Proper
WARNING
Risk of getting caught.
Please do not set ON delay 2sec. to “ON” when door cancel function is “ON”.
If both are "ON" , the sensor does not output signal unless it detects a person
or object more than 2sec and 1st row is inactive.
If the person or object enter the fist row, the sensor does not detect and door
never opens.
WARNING
Risk of getting caught.
Alarm display
Refer to the
TROUBLESHOOTING
below when the following appears.
Life cycle notification
Twice green blinking
Signal Saturation
Slow green blinking
Status
Operation indicator
2sec.
60sec. 10min.
4
3
4
3
4
3
4
3
When people or objects enter more than 2 spot areas, this function automatically sets the presence
detection timer to infinity to increase safety and avoid unwanted door opening due to sudden change
in floor condition.
NOTE
Adjust the sensitivity to suit each installation site.
When "2rows" is selected, the activation output
is disabled.
NOTE
Simultaneous
output
Simultaneous
output
ON
15
OFF
15
13
N.C.
13
N.O.
14
N.C.
14
N.O.
13
N.C.
13
N.O.
14
N.C.
14
12
12
1st & 2nd 1st to 5th
With dipswitch 12 “1st & 2nd” , presence detection timer for 1st & 2nd rows belong to
dipswitch 3 and 4. Presence detection timer for 3th to 5th row automatically becomes 2 sec..
With dipswitch 12 “1st to 5th” , presence detection timer will be same as all detection area,
set by combining dipswitch 3 and 4.
2
Area width adjustment
When adjusting the width adjustment screws, make sure to turn until they click otherwise proper
operation may not be obtained.
cannot be eliminated separately, neither can .
NOTE
1 2 3
10 11 12
Width adjustment
screws (Left)
1st to 3rd rows
Narrow
Wide
Eliminated
Eliminated
Eliminated
Eliminated
1 2 3
10 11 12
Width adjustment
screws (Right)
4th and 5th rows
Narrow
Wide
Eliminated
Eliminated Eliminated
Eliminated
1 2 3
10 11 12
Front view
2.0
(6’7”)
3.0
(9’10”)
4.0
(13’2”)
4.5
(14’9”)
0
1.0
(3’3”)
1.0
(3’3”)
2.0
(6’7”)
2.0
(6’7”)
3.0
(9’10”)
3.0
(9’10”)
[mm(feet,inch)]
12
1 2 3 4 5 6 7 8 9 10 11
: 2.5m(8’2”) to 3.5m(11’6”)
: 3.0m(9’10”) to 4.0m(13’2”)
: 3.5m(11’6”) to 4.5m(14’9”)
: 4.0m(13’2”) to 4.5m(14’9”)
L (Low)
M (Middle)
H (High)
S-High(Super high)
ON
OFF
15
15
Simultaneous
output
The activation and safety outputs can be selected separately
( N.C. or N.O. by dipswitch 13 and 14 )
With this fuction, 1st row is disabled if there are no ditection for 10sec.
If a person or vehicle enter the first row without any detection in other rows
(e.g. enter from the other side), it might cause an accident.
All manuals and user guides at all-guides.com