Optex IVP-GU iVISION+ Скачать руководство пользователя страница 2

WARRANTY

10.

SPECIFICATION

9.

PAIRING WITH OPTEX WIRELESS2000 SYSTEM

7.

MODEL NAME: OPTEX  (IVP-GU) Gateway Chime Unit

Operating Temperature

9-1

Dimensions

9-2

Specification Table

ADDITIONAL SETTING

8.

TD-20U

(STEP 3) Send pairing signal to IVP-GU

(4) Press IVP-DU push button once and hold paring button located at the bottom
     of battery compartment until it makes a keeping sound.  

Gateway Chime Unit (IVP-GU) can be paired with OPTEX TC-10U & TD-20U devices.

7-1

Pairing TC-10U & TD-20U to Gateway Chime Unit

To change a chime volume of IVP-GU

– Press button A to acknowledge current chime volume level. Press A button again to 

   change volume level to the next. The volume changes within 4 levels and the lowest

   volume will follow the loudest. Leave the setting at the desirable volume level.

   To completely turn off the chime, set Sound ON/OFF Switch to OFF.

When paired with TC-10U or TD-20U, following features are available;

- If corresponding Door Camera Unit (IVP-DU) is connected to an external

  power source, TC-10U or TD-20U can trigger an image capture from the IVP-DU.

- IVP-GU can act as an extra chime unit in WIRELESS2000 system.

IVP-GU

NOTE: Please configure IVP-GU before pairng WIRELESS2000 device.

To connect system to OPTEX WIRELESS2000 devices (e.g. TC-10U) 

HOME ID must be assigned to IVP-GU prior to pairing. 

110mm / 4.33”

80mm / 3.15”

Dust/Water Protection
Radiowave Frequency

0 to 40 degC (32 to 104 degF)
< 90% RH (no condensation)
N/A (Indoor Use Only)
2.4 GHz and 418MHz

Operating Humidity

Power

AC/DC 10-24V 3W(max)

One IVP-GU can host 2 units of TC-10U or/and TD-20U, each into zone 1 and 2.

Both zone 1 and zone 2 will be associated to a Door Camera Unit (IVP-DU) which is

corresponding to the IVP-GU. In total, one system can host

4 WIRELESS2000 devices through 2 IVP-GUs. 

5921751
REV 1.01

OPTEX INC. (U.S.)

URL: http://www.optexamerica.com/

OPTEX DO BRASIL LTDA. (Brazil)

URL: http://www.optex.net/br/es/sec/

OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)

URL: http://www.optexeurope.com/

OPTEX CO., LTD. (JAPAN)

URL: http://www.optex.net/

TC-10U

(STEP 4) Confirm operation of WIRELESS2000 devices

TD-20U

TC-10U

After inserting a

battery, remove 

magnet part of 

the device away

from the TC-10U.

After inserting a

battery, wave your

hand across front

of the TD-20U

NOTE: How to trigger WIRELESS2000 devices

(STEP 2) Prepare IVP-GU into a pairing mode

Enter into a pairing mode by holding down B button. 

LED starts blinking. Select a zone by pressing B button.

The pairing mode continues for 30 seconds.

While the IVP-GU is in a pairing mode for a designated zone, trigger TC-10U or

TD-20U to send a radio signal. IVP-GU will register the signal with a chime.

Exit the pairing mode by holding down B button.

LED stops blinking when in a normal operation mode.

Trigger the paired WIRELESS2000 device. IVP-GU will blink LED and ring a chime

(Sound ON/OFF Switch must be ON). IVP-HU will also respond by a chime sound

unless a volume on IVP-HU is set to null. IVP-HU will also capture an image from 

a corresponding IVP-DU if the IVP-DU is connected to an external power source.

SENSOR ALERT mode Enable/Disable setting

– By disabling SENSOR ALERT mode, system become ignorant of connected

  WIRELESS2000 devices. This setting is changed by holding “Right Function Key” on

   a Handheld Monitor Unit(IVP-HU). The LED on IVP-GU indicates the current setting.

              When in RED, SENSOR ALERT is Enabled.

              When in GREEN, SENSOR ALERT is Disabled

30.3mm / 1.2”

NOTE: Low battery notification of WIRELESS2000 devices

If a zone of IVP-GU already has an assigned WIRELESS2000 device, the zone will

not be overwritten and register another WIRELESS2000 device.  

When pairing is denied, rapid beeps will sound.

(STEP 1) Clear/initialize IVP-GU for a new pairing of WIRELESS2000 devices
Enter into a pairing mode by holding down B button. LED starts blinking. 

Select a zone by pressing B button. Hold down A button until two short beeps sound. 

Repeat the same process for another zone if necessary. Exit the paring mode by 

holding down B button or proceed to STEP3 if pairing immediately.

     Zone 1, LED blinks slowly at 1 Hz (Green/Red) 

     Zone 2, LED blinks fast at 2 Hz (Green/Red)

When any paired WIRELESS2000 has a low battery condition,  

IVP-GU will make a short beep following a chime sound.  

Low battery beep does not sound if the sound switch on IVP-GU is set to OFF.

1.  This product is under a warranty for a normal usage for 18 months from the date 

     of manufacturing. The date of manufacturing can be identified from a LOT number

     indicated on a label placed in a back of IVP-GU.

2.  The warranty may not be applicable when any of following circumstances is found.

    - Mechanical or electrical modification is made to the product and the good’s 

      appearance indicates an alterations or a significant damage.

    - The product is already been diagnosed by someone other than the manufacturer.

    - Product malfunction is resulting from an improper usage, an accident, 

      natural disaster or any environmental event.

    - Please call our technical assistance before arranging a return.

LOT: YYWWZ   (e.g.  LOT 1350Z)

YY indicates last two digits of the year manufactured  (e.g. “13” = Year 2013)
WW indicates Xth week of the year manufactured        (e.g. “50” = 50th week)

Pairing button A

 

& B

LED (RED/GREEN)

Relay Output

1C 50VAC/24VDC 1A max

* HOME ID is an unique identification number for your system.  

Pairing button

Sound ON/OFF Switch

The Gateway Chime Unit operates regardless of
the switch setting while power is being supplied.

This switch is for turning 
ON/OFF a speaker.

Pairing button A

 

& B

Top view

Unit (IVP-HU)

Отзывы: