 INS-QXI-ST 

Passive infrared

12.0 m (40') 75°wide

32 zones

0.3 to 2.0 m/s (1' to 6'7"/s)

2.0

 ( 3.6°F) at 0.6 m/s

PoE (IEEE 802.3af compliant)

Mini-jack 12 V DC 420 mA max.

Terminal 9.5 to 16 V DC/ 20 mA max. at 12 V DC

2.0 ± 0.5 s

Approx. 60 s (LED blinks)

N.C/N.O. switchable, 28 V DC 0.1 A max.

    N.C. 28 V DC 0.1 A max.

Open when the cover is opened

[1] Warm-up      [2] Alarm      [3] Walk test end

1/2.8” CMOS

H: 114°   V: 61°

Color: 0.02 lux.  0 lux. with IR

Visible up to 12 m

Day & Night Automatic/Manual switching

H.264, H.265, MJPEG

1080/ 30 fps, D1 (704 x 480 or 704 x 576)

IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP,

HTTPS, SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF

HTTPS(SSL), IP filtering, 802.1x, Digest authentication (ID/PW)

-30

 to +50

(-22°F to +122°F)    

95% max.

IP 54

Wall (Outdoor, Indoor)/Gang box

2.2 to 2.7 m (7' 3" to 8'11")

xxx

 g (

x.xx

 oz)

[1] Mounting screw (4 x 20 mm) x 2   
[2] T20 Torx wrench x 1
[3] Area masking strips x 1
[4] Waterproof cap for LAN connector x 1

Model

Detection method
PIR coverage
PIR zones
Detectable speed
Sensitivity

Power input

Alarm period
Warm-up period
Alarm output
Tamper output
LED indicator
Image sensor
Viewing angle
Minimum illumination
IR illumination
Night vision
Image compression
Resolution/ frame rate
Network protocol
Security
Operation temperature
Environment humidity
International protection
Mounting
Mounting height
Weight

Accessories

  

Содержание InSight INS-QXI-ST

Страница 1: ...semble 1 2 Mounting 1 3 Fall prevent wire 1 4 Wiring 1 5 Assembling 4 1 PIR area direction 4 2 PIR area masking 4 3 Switch settings 4 4 Walk test 4 5 LED indicator Page 2 3 5 6 12 13 14 IP camera sett...

Страница 2: ...tes prohibition Special attention is required to the section of this symbol Symbol Meaning Symbol Meaning Warning Caution NOTE Warning Caution Tilt Before installation Parts identification 2 Accessori...

Страница 3: ...1 Installation Step Remove the main unit and the mounting plate 1 2 Mounting 1 3 Fall prevent wire Hook the fall prevent wire 1 1 Disassemble 3 1 2 3...

Страница 4: ...connection Caution The connector can be fixed inside the main body with double sided tape NOTE 1 5 Assembling Replace the main unit with the mount base 1 2 1 Installation Step 4 Cut the rubber and pu...

Страница 5: ...Camera Setting Manual 3 Registration InSight to CHeKT portal site Step 5 The default network type of InSight is dynamic If you have a DHCP server it will automatically set the IP address 1 Setup your...

Страница 6: ...aise the Back cover up Pull it back Adjust PIR area direction Angle can be adjusted with either left or right screw 4 1 PIR area direction 1 2 The display of the detection area helps to set the area 6...

Страница 7: ...area masking 1 7 Lock screw Use as necessary Remove before if used 1 Unlock the cover using a screwdriver 2 Lift the cover up Attach the area masking strips a b c d b c d a b c d b c d e PIR area mas...

Страница 8: ...ut N O N C LED ON OFF 3 4 3 4 3 4 3 4 Low Middle PIR sensitivity High Super High 1 2 3 4 5 6 7 8 Default Default Future use Do not move the mirror nor PCB from the factory settings as Pet alley cannot...

Страница 9: ...a to make sure it is set as intended If necessary turn LED OFF again Fix the cover with the cover lock screw included in the housing after completion as necessary 2 For the walk test walk at least 1 0...

Страница 10: ...10 Camera angle settings 5 Step Default Camera angle adjustment Loosen the screw to adjust camera angle Angle can be adjusted with either left or right screw 20 min 35 max 30 1...

Страница 11: ...a display of the detector on the screen will be different from the actual one Adjust the display on the web See the IP camera manual System check 6 Step Check the image at the time of detection on the...

Страница 12: ...20 6 6 20 35 30 25 9 20 6 2 2 m 0 15 10 5 0 3 12 m 40 ft 2 7 m b c d e e f b c d f Area on both sides are masked with the area strips by default e a PIR Camera Caution 7 3 8 11 Pet alley can not be se...

Страница 13: ...02 lux 0 lux with IR Visible up to 12 m Day Night Automatic Manual switching H 264 H 265 MJPEG 1080 30 fps D1 704 x 480 or 704 x 576 IPv4 TCP IP UDP RTP UDP TCP RTSP NTP HTTP HTTPS SSL DHCP SNMPv1 v2...

Страница 14: ...Dimensions Others 14 Unit mm inch 214 8 43 84 3 31 209 8 23 140 5 51 83 5 3 29...

Страница 15: ...notification when using this product User of this product is deemed to be responsible for the compliance of any laws and regulations relating to personal information privacy protection and rights of...

Страница 16: ...AS France www optex europe com fr OPTEX SECURITY Sp z o o Poland www optex europe com pl OPTEX PINNACLE INDIA PVT LTD India www optexpinnacle com OPTEX KOREA CO LTD Korea www optexkorea com OPTEX DONG...

Отзывы: