background image

18730 Wilmington Ave, Unit 100

Rancho Dominguez, CA 90220

Ph 310 214-8644

Fax 310 898-1098

Toll free 800 877-6656

www.ot-inc.com

OPTEX Technologies Inc.

(East Coast Office)

8510 McAlpine Park Dr.

Suite 108

Charlotte, NC 28211

OPTEX Technical Support (800) 877-6656 

East Coast: Perry Watkins, Ext. 220 

Central U.S.: Jason Kirn, Ext. 201

Support: Refugio Guadaljara, Ext. 202

Area Depth Angle Adjustments

Sensitivity Adjustment

Cover Installation

Troubleshooting

Operation LED turns FLASHING RED, then the door reopens 

(Row 2 Presence Detection Door).

Adjust Presence/Motion adjustment screw Clockwise until ghost-

ing stops.

Note: Before making adjustments set dipswitch 18 ON, once 

adjustment are complete set dipswitch 18 Off.

Operation indicator table

Status

Operation Indicator color

Stand-by (installation mode)
Stand-by (operation mode)
BLUEZONE (1st row) detection
2nd row detection
3rd-4th row detection
5th row detection
Approach (6th row) detection
Signal saturation
Sensor failure

Slow green blinking
Fast green blinking

Orange
Orange blinking

Red blinking
Red

Green
Blue

Yellow

1sec

The cover locking tab on the sensor must align with 
the locking catch on the sensor cover.

High

Low

Approach sensitivity

Presence/Motion 

sensitivity

The Presence/Motion sensitivity potentiometer is used to adjust the detec-
tion area sensitivity for rows 1-5. The Approach sensitivity potentiometer is 
used to adjust the detection area sensitivity of row 6. Turning clockwise in-
creases the sensitivity; turning counterclockwise decreases the sensitivity.

Use the area adjustment tool to change sensitivity.

Depth angle adjustment 

screw for the Presence/

Motion area.

Depth angle adjustment 

screw for the Approach 

area.

-6

-10

+8

0

+4

-2

The Presence/Motion area angle depth 
adjustment screw adjusts rows 1-5 
simultaneously. 

Shallow

Deep

Shallow

Deep

-15

+10

-10

0

-5

The Approach area angle depth 
adjustment screw adjusts row 6 
independently. 

Note: Walk Test

Power up sensor and wait 
10 seconds prior to walk 
testing the presence area. 
Perform walk test procedure 
to verify substantial com-
pliance with ANSI/BHMA 
A156.10 section 8.

(Continued from other side)

Push cover straight into the locking tab on the sensor.

Note: Walk Test

Perform walk test procedure to verify substantial compliance with 
ANSI/BHMA A156.10 section 8.

Отзывы: