18730 Wilmington Ave, Unit 100
Rancho Dominguez, CA 90220
Ph 310 214-8644
Fax 310 898-1098
Toll free 800 877-6656
www.ot-inc.com
OPTEX Technologies Inc.
(East Coast Office)
8510 McAlpine Park Dr.
Suite 108
Charlotte, NC 28211
OPTEX Technical Support (800) 877-6656
East Coast: Perry Watkins, Ext. 220
Central U.S.: Jason Kirn, Ext. 201
Support: Refugio Guadaljara, Ext. 202
Area Depth Angle Adjustments
Sensitivity Adjustment
Cover Installation
Troubleshooting
Operation LED turns FLASHING RED, then the door reopens
(Row 2 Presence Detection Door).
Adjust Presence/Motion adjustment screw Clockwise until ghost-
ing stops.
Note: Before making adjustments set dipswitch 18 ON, once
adjustment are complete set dipswitch 18 Off.
Operation indicator table
Status
Operation Indicator color
Stand-by (installation mode)
Stand-by (operation mode)
BLUEZONE (1st row) detection
2nd row detection
3rd-4th row detection
5th row detection
Approach (6th row) detection
Signal saturation
Sensor failure
Slow green blinking
Fast green blinking
Orange
Orange blinking
Red blinking
Red
Green
Blue
Yellow
1sec
The cover locking tab on the sensor must align with
the locking catch on the sensor cover.
High
Low
Approach sensitivity
Presence/Motion
sensitivity
The Presence/Motion sensitivity potentiometer is used to adjust the detec-
tion area sensitivity for rows 1-5. The Approach sensitivity potentiometer is
used to adjust the detection area sensitivity of row 6. Turning clockwise in-
creases the sensitivity; turning counterclockwise decreases the sensitivity.
Use the area adjustment tool to change sensitivity.
Depth angle adjustment
screw for the Presence/
Motion area.
Depth angle adjustment
screw for the Approach
area.
-6
-10
+8
0
+4
-2
The Presence/Motion area angle depth
adjustment screw adjusts rows 1-5
simultaneously.
Shallow
Deep
Shallow
Deep
-15
+10
-10
0
-5
The Approach area angle depth
adjustment screw adjusts row 6
independently.
Note: Walk Test
Power up sensor and wait
10 seconds prior to walk
testing the presence area.
Perform walk test procedure
to verify substantial com-
pliance with ANSI/BHMA
A156.10 section 8.
(Continued from other side)
Push cover straight into the locking tab on the sensor.
Note: Walk Test
Perform walk test procedure to verify substantial compliance with
ANSI/BHMA A156.10 section 8.