background image

F

requently

 

 

A

sked

 

Q

uestions 

Reference For Sales Purpose Only 

All rights reserved by OPTEX Co., Ltd. 2009 

For 

Battery Operated 

Photoelectric Detectors 

AX-100TFR 

AX-200TFR 

Содержание AX-100TFR Series

Страница 1: ...Frequently Asked Questions Reference For Sales Purpose Only All rights reserved by OPTEX Co Ltd 2009 For Battery Operated Photoelectric Detectors AX 100TFR AX 200TFR...

Страница 2: ...Rs P 5 Q 10 What happens if I accidentally insert batteries upside down P 5 Q 11 At what power voltage Low battery signal is turned on P 5 Q 12 How can I be aware of Low battery status P 6 Q 13 Why ca...

Страница 3: ...X Aspherical Lenses Sharper Focus Conventional Spherical Lenses Blurring Focus Q 01 How efficient is the AX TFR s energy consumption compared to conventional wired model A 01 Compared to OPTEX wired p...

Страница 4: ...nuated photobeams without malfunctioning Q 04 What is the power range VDC required to run AX TFR A 04 AX TFRs are designed to run with current between 2 5 VDC 4 3 VDC Q 05 Why do I have to use SAFT s...

Страница 5: ...Use four LSH20 batteries manufactured by SAFT not included Battery life is stated for a condition that it is used within the ambient temperature range of 20 to 25 degree Celsius Battery life of AX 20...

Страница 6: ...hile front cover is opened While the front cover is closed LED indicator is put off to minimize power usage 2 Using Wireless transmitter for receiving Low battery signal If a wireless transmitter is a...

Страница 7: ...not share battery powers with wireless transmitters because AX TFRs do not comply with low battery voltages assigned in most of wireless transmitters If overridden there is a risk that before wireless...

Страница 8: ...to each other to secure reliability Configuration example for a double stacking protection Q 16 Can I arrange AX TFRs in a stack A 16 Yes Double stacked protection is possible Important notes Between...

Страница 9: ...recognized with the tamper bushing inserted Remove the tamper bushing before selecting a function using the switch After completion of the settings be sure to insert a tamper bushing and please check...

Страница 10: ...Spacious Universal design A Backbox can accommodate two wireless transmitters Battery holder is designed to ignore batteries installed upside down Double sided tapes are also included in a package to...

Страница 11: ...Protection IP rate is the standard defined by IEC60529 AX TFRs rating is IP55 The first numeral indicates degrees of protection against dusts The second numeral indicates degrees of protection against...

Страница 12: ...nnot be accommodated either When using AX TFRs in a tower usage of the HU 2 is an option however HU 2 will not produce enough heat to resist frost and condensation inside the tower Q 21 What outputs a...

Страница 13: ...tive if your wireless transmitters do not have supervised features to monitor relay status For an example with such transmitters security system can be armed while beams are interrupted by an accident...

Страница 14: ...put preserving powers of wireless transmitters Important note Apply same switch settings to the both TX and RX of AX TFRs to enable the function Q 26 Do lightning damage AX TFRs A 26 No because AX TFR...

Страница 15: ...aid an understanding of AX TFRs features and specifications Please also refer to Installation Instruction manual enclosed in TFRs packages for detailed procedures and setting configurations The manua...