22.4
Frequency of Extra Fixings for Different Regions
For ultimate wind loadings
(see Tables above):
Extra Fixings Required
Less than 70Kg per panel
Stainless guide line is not required (but still recommended)
Greater than 70Kg per panel
Stainless guide line is required across each row
Greater than 120kg per panel
Stainless guide line is required
with
in-between anchor points
22.5
Roof Edge High Wind Loading Zones
Note: Collector installations within a roof edge high wind loading zone will require
2 X
the
fixing strength in that local area. Collector installations within a roof corner high wind loading
zone will require
3 X