background image

 

 

VBS 2020 RX-3 

 

Triple optical video receiver 

 

USER MANUAL 

 
 

1. General description 

 

The VBS 2020 RX-3 plug-in module contains three 
identical optical video baseband receivers. Optical 
input to each of these separate analogue receivers is 
converted into the electrical video equivalent. 
Signal integrity is preserved with the aid of 
automatic gain control and video clamping, making 
installation and operation adjustment-free. The 
units receive at an optical wavelength of 850 nm 
and must be connected to multimode optical fibre. 
The 7TE modules will slot into the backplanes of 
Optelecom-NKF's MC 10 or MC 11 power supply 
cabinets. Details specific to the stand-alone option 
(/SA) are described in a supplementary manual. 
VBS 2020 RX-3 receivers are suitable for use in 
combination with ADV transmitters/receivers, 
allowing inclusion of two independent streams of 
digital data and/or high quality audio in each video 
signal. 
 
 

2. Indicators and connectors 

 
Figure 1 shows the signal connection facilities and 
indicators on the front panel of a VBS 2020 RX-3 
receiver module (see also table 1). 
 

o

 

 , 3x

 

video

 

output

 

(75

 

Ω

 

BNC

 

conn.) 

o

  

 

 , 3x

 

optical input (ST connector) 

Status indicator LEDs   

* DC 

DC power supply 

* NV

,

 

3x

 

no video at output 

Table 1. Indications and connectors on the front panel 

of the VBS 2020 RX-3

 

 
 

3. Installation instructions 

 

1.

 

VBS 2020 RX-3 units should always be used in 
combination with Optelecom-NKF power 
supply cabinets; for /SA version, please consult 
the supplementary manual. 

2.

 

Plug the module into the power cabinet and 
connect suitable video and optical fibre 
equipment to the modules. 

3.

 

After activating the power supply, at least the 
green DC LED on the front panel should glow. 

4.

 

Upon feeding an optical RX-3 input with a 
proper signal, the corresponding NV LED (red) 
should go out. 

If this is not the case, please 

check the optical link

 

 

4. Care and maintenance

 

 

In order to maintain reliable operation of the 
module, please observe the following: 
- Prevent dust from collecting on the equipment 
- Protect the equipment against moisture 
- Maintain sufficient free space around the equip-

ment for cooling. 

 
General safety and EMC information will be found 
in the final section of this document. 

Figure 1. 

VBS 2020 RX-3 

front panel layout 

VBS RX-3

DC

CH1

CH2

CH3

NV

NV

NV

VBS RX-3

DC

CH1

CH2

CH3

NV

NV

NV

Отзывы: