Support and Manuals
5 / 6
Maintenance
1. Nozzle Removal
For cutting materials thicker than 3.5 mm the air nozzle should be removed. To remove the air
nozzle, unscrew it as shown in the images below.
Important:
Never
unscrew or loosen the screws shown in the image below. The part that they
are holding is factory aligned.
2. Air Nozzle Connection
High pressure nozzle can be connected via a 4 mm (5/32") hose. The hose is meant to be guided
through the hole at the back of the laser head. It is important that you ensure the nozzle has got
a fresh air supply.