Opkon OP-CN4 Скачать руководство пользователя страница 4

  

                        

                                                       

   SUBMENU SETTINGS 

   

 1. SEt1

 SEt1

 is the value of 

Relay1

 turns active. (please refer to 

tOut1

 for duration of activation of Relay1).

 • 

Press

 

SET

 

button to enter  the submenu When stay on

 

SEt1

• 

Please refer to 

"

 enterring the CodE.

"

• 

Press

 

UP/DOWN

 

buttons to set the value

• 

Press

 SET

 button to shift the row on left.

• 

After setting all the rows 

 

Press

 

SET

 button finally to save the value.

• 

If u want to back menu 

without  saving

  

Press

 

RST

 button 

(ESCAPE).

• 

Then equipment backs to main menu automatically.

    2. SEt2

 

SEt2 

is the value of 

Relay2

  turns active. (please refer to 

tOut2

 

for duration of activation of Relay1).

• 

Press

 

SET

 button to enter the submenu When stay on

 

SEt2.

 

• 

Please refer to 

"

 enterring the CodE.

"

• 

Press

 

UP/DOWN

 

buttons to set the value

• 

Press

 SET 

button to shift the row on left.

• 

After setting all the rows 

Press

 

SET

 button finally to save the value.

• 

If u want to back menu 

without  saving

  

Press

 

RST

 button (ESCAPE)

 

• 

Then equipment backs to main menu automatically.

   

   

     
    3. CALH (CALIBRATION)

 

MODEL-CN5 is an Incremental  Counter, as well as owing to scaled and calibrated, it is operated as  a 
Distance/Angel Measurement Equipment. Therefore,occured the LENGTH by Sensor movement 
mechanically is matched the Value seen on the screen.

Sample

:  When the Senor makes 5000 pulse movement

 

Mechaically,

In order to see 100.00 on the screen;

• 

Move

 the sensor to the designated position mechanically.

•  

Press

 

RST

 

 button to  

zero

 the counter display.

•  

Move on

 the sensor to make 5000 pulse on the display.

• 

After the 5000 pulse occured  

Press

 

SET

 

button to enter the main menu.

     •  

Press DOWN

 

button for 3 times and stay on

 

CALH

 submenu.  

• 

Press

 .

SET

 

button to enter the submenu.

     • 

Please refer to 

pg.5

 for enterring the CodE  

  • 

Press

 

UP/DOWN 

 

buttons and write “0100.00”.

     •

 After setting all the rows 

Press

 

SET

 button finally to 

save 

the value  

•  

Then equipment backs to main menu automatically.

     •  

Anymore,While the INCR mode is not used, for 5000 Pulse 100.00 is written on the  screen.(Look at dSPtYP for INCR mode).  

 

    

   4. Poınt

 This Parameter defines the Decimal Point.

•  

Press

 

SET 

 button to enter the submenu When stay on 

Poınt

• 

Please refer to 

"

 enterring the CodE.

"

•  

Press

 

UP/DOWN

 

buttons to shift the point.

•  

Press

 

SET 

button to save the point 

•  

If u want to back menu 

without saving

 

Press

 

RST

 

button (ESCAPE).

•  

Then equipment backs to main menu automatically.

      5. toUt1

 This parameter is used to keep in active durationof the RELAY1 in seconds(s). 

Sample

: For 1 second 

duration of RELAY1; 

•  

Press SET

 

button to enter the submenu When stay on

 

toUt1

• 

Please refer to 

"

 enterring the CodE.

"

•  

Press UP/DOWN  

buttons to write 

00001.0

” 

on the display..

• 

 

Press

 

SET 

button to save.

•  

If u want to back menu

 

without saving Press RST 

button 

(ESCAPE). 

•  

Then equipment backs to main menu automatically.

• 

Write to display

 “000000” 

for duration continuosly  

(HOLD).

  

 6. toUt2

 This parameter is used to keep in active durationof the RELAY2 in seconds(s). Sample: For 1.4 second  
duration of RELAY2; 

•  

Press

 

SET 

 button to enter the submenu When stay on 

toUt2

• 

Please refer  to 

"

 enterring the CodE.

"

•  

Press  UP/DOWN

 

buttons to write

 “

00001.4

” 

on the display..

•  

Press

 

SET

 button to save.

•  

If u want to back menu 

without saving

 

Press

 

RST

 button 

(ESCAPE). 

•  

Then equipment backs to main menu automatically.

•  

Write to display 

000000

” 

for duration continuosly  

(HOLD

).

  

7. PrSCL

 This parameter is used  as a Multiply Coefficient.In CALH Parameter setup,If  the right value is not able 
to been create mechanicly, the Calibration can been  made by calculating the coefficient 
Mathematically.Write it in space 0.001<PrSCL<99000 .
When the PrSCL value changed,the Previous Calibration data is deleted automaticaly.

•  

Press

  

SET 

 button to enter the submenu When stay on 

PrSCL.

• 

Please refer  to 

"

 enterring the CodE.

"

•  

Press 

 

UP/DOWN

 

buttons to write the calculated value.

•  

Press

 

SET

 

button to save.

•  

If u want to back menu 

without saving

 

Press

 

RST

 

button (ESCAPE).

                                                 •  

Then equipment backs to main menu automatically.

  

8. oUt

 This parameter is used to define the Operation Types of the Realy1 and Relay2.please refer OUTPUT 
TYPES

•  

Press

  

SET

 

 button to enter the submenu When stay on oUt.

• 

Please refer  to 

"

 enterring the CodE.

"

•  

Press 

 

UP/DOWN

 

buttons to write  among 

0-9

 a number .

•  

Press

 

SET

 button to save.

•  

If u want to back menu 

without saving

 

Press

 

RST

 button (ESCAPE).

•  

Then equipment backs to main menu automatically.

     
  9. oFFSEt

 This Parameter is used to define  the initial value of the Counter, When Pressed the RST button or an 
external  Z/Reset Pulse enabled.After this Resettlement the counter count forward or reverse from new 
OFFSET  value. The Default Counter value is zero

•  

Press

  

SET

 

 button to enter the submenu When stay on 

oFFSEt.

• 

Please refer  to 

"

 enterring the CodE.

"

•  

Press 

 

UP/DOWN

 

buttons to write the ofset value.

•  

Press

 

SET

 button to save.

•  

If u want to back menu 

without saving

 

Press

 

RST

 

button (ESCAPE).

•  

Then equipment backs to main menu automatically.

  10. ınrST

This Parameter is used to define that, in which EDGE of External Z/Reset pulse, the Counter will  
reset.Available 3 states

•  

Press

  

SET

 

 button to enter the submenu When stay on

 ınrSt.

• 

Please refer  to 

"

 enterring the CodE.

"

•  

Press 

UP/DOWN

 

buttons and select one of this condition.

1. 

norSt

 

:Disable Z/Reset.

2.

 FALL

 :Triggered by the falling edge of Z/Reset.

3. .

riSE 

  :Triggered by the rising edge of Z/Reset.

 •  

Press

 

SET

 

button to save.

                                                   •  

If u want to back menu 

without saving

 

Press

 

RST

 button (ESCAPE). 

                                                   •  

Then equipment backs to main menu automatically.

Отзывы: