Страница 1: ...MADE IN ITALY design production LCD THERMO PRODUCTS USER MANUAL AMLETO IDRO FEDORA IDRO OTELLO IDRO RIGOLETTO IDRO ENGLISH INGLESE...
Страница 2: ...2...
Страница 3: ...essel system 7 Distances of safety devices according to the Standard 7 Commissioning checks 7 Automatic thermostatic mixer valve mandatory 7 Hydraulic plant basic layout 8 OTELLO IDRO hydraulic connec...
Страница 4: ...c 25 Additional thermostat 26 Additional thermostat functioning with stby active 26 Additional thermostat Operation with deactivated stby 26 Additional thermostat installation 26 aux 26 User menu 27 S...
Страница 5: ...dvised to position the power supply cable so that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the d...
Страница 6: ...ried out by professionally authorised staff Ministerial Decree dated 22 01 08 n 37 The manufacturer declines all responsibility for damages to objects and or persons caused by the system TYPE OF SYSTE...
Страница 7: ...ing of certain system components pumps valves etc b check to verify that the flue has adequate draft is not narrowed and that other appliances do not discharge into the flue This is to prevent unexpec...
Страница 8: ...ry air inlet B Flue exhaust outlet C Circulator pump in the models where provided T1 3 bar safety drain T2 Boiler flow outlet T3 Boiler return inlet M Manometer T Thermometer G Filling system S Safety...
Страница 9: ...hen the complete right front panel 7 Connect the system flow T2 to the machine and the safety valve pipe T1 Refer to the template for the correct position T1 T2 8 Connect the system return T3 to the m...
Страница 10: ...ct that can be managed with the integrated expansion vessel An additional expansion vessel must be installed for a higher content of water The following graph shows the behaviour of the circulator pum...
Страница 11: ...operation with closed combustion chamber Forced draught appliance Appliance with ventilation in the fumes circuit and combustion with fumes flow at a positive pressure with respect to the environment...
Страница 12: ...anyrestrictionsrequiredbylocaladministrativeregulations specialorconventional requirements resulting from condominium regulations constraints laws or administration deeds must precede any other assemb...
Страница 13: ...itable load bearing capacity to support the weight of the appliance of the accessories and coatings Theadjacent sideandrearwallsandthesupportingsurfacemustbemadeofnon combustiblematerial Installationn...
Страница 14: ...ust discharged above the roof Direct discharge from the wall or towards closed spaces is forbidden even with clear skies In particular it is forbidden to use flexible and extendible metal pipes The ch...
Страница 15: ...al pipes to connect the appliance to the chimney is not allowed nominal diameter distance from combustible materials indicated in millimetres followed by the arrow and flame symbol installer data and...
Страница 16: ...FUMES EXPULSION For the heat generator appliances equipped with electric fan for expelling fumes the instructions below must be followed The horizontal sections must have a minimum upward slope of 3...
Страница 17: ...t of operating in damp conditions a device for reflux drainage condensation rainwater Ducted system A ducted system can be installed with one or more ducts operating only with negative pressure with r...
Страница 18: ...the restoration of the initial conditions by replacing the gaskets and damaged items and cleaning those remaining in use Ignition tests Operation of the appliance must be verified with an ignition tes...
Страница 19: ...OF APPLIANCE INSTALLED 15kW 15 35 kW Pellet operated appliance 1 year 1 year Water operated appliances closed fireplaces thermo stoves thermo kitchens 1 year 1 year Boilers 1 year 1 year Fumes exhaust...
Страница 20: ...pellets must be stored in a dry place Open the tank lid and load the pellets using a scoop CHECKS AND PRECAUTIONS FOR FIRST IGNITION IMPORTANT IN ORDER FOR THE GENERATOR TO WORK PROPERLY THE HYDRAULI...
Страница 21: ...s over the set temperature set On the T read by the probe is below the set temperature set Indicates the contact of the external additional thermostat On closed contact the contact of the external add...
Страница 22: ...faces as they could still be unstable Air the room well several times The hardening of the surfaces is terminated after several heating processes This appliance must not be used to burn waste Before i...
Страница 23: ...NU this key provides access to the user and technical menu the technical menu is reserved for assistance 9 INCREASE This button allows increasing the temperature setpoint 10 ESC KEY This key allows th...
Страница 24: ...rm using key 6 Select the language using key 4 o 5 Confirm using key 6 then key 1 to exit the Menu SET LANGUAGE LANGUAGE ITALIAN ENGLISH GERMAN FRENCH SPANISH J NO IGNITION FIRST IGNITION COULD EVEN F...
Страница 25: ...rovided front ventilation can be activated deactivated and room temperature can be verified by means of the room probe standard See chapter enable fan in the following pages BURN POT CLEANING While wo...
Страница 26: ...xternal thermostat is not satisfied open contact temperature reached the stove will go to minimum As soon as the contact or external thermostat passes to the not satisfied status closed contact temper...
Страница 27: ...4 5 to enable disable ventilation Press key 6 to confirm and 1 to return to the menu back to the initial status 1 DISPLAY This menu allows to regulate the brightness of the display The possible setti...
Страница 28: ...it is only burned partially The regulation to be performed is a percentage Therefore a modification of this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from...
Страница 29: ...y 2 until RESET is displayed Use keys 4 5 to select ON and press key 6 The word DONE will be displayed to confirm SET H2O 75 C SET TEMPERATURE 35 C SET POWER 5 ENABLE CHRONO OFF START PRG1 OFF STOP PR...
Страница 30: ...excluding Saturday and Sunday OFF MONDAY PRG1 ON OFF Press key 6 to confirm and continue programming START PRG1 OFF will appear START PRG1 OFF SET H2O TEMPERATURE 1ST TIME SPAN Press key 6 to confirm...
Страница 31: ...specified in this use and maintenance manual must be performed with the utmost care according to the instructions procedures and frequency intervals described in this use and maintenance manual CLEANI...
Страница 32: ...sing a suction device Suck the ash deposited in the brazier compartment Scrapers Cleaning of the heat exchangers allows to guarantee constant heat output through time This type of maintenance must be...
Страница 33: ...every week or when required It is recommended to remove the ash in the combustion chamber at least once a week using a suitable vacuum cleaner MONTHLY For the model in the picture below it is recomme...
Страница 34: ...GASKETS ASH DRAWER AND BURN POT Gaskets guarantee the hermetic seal of the stove and its ensuing correct operation They must therefore be checked regularly should they be worn or damaged replace them...
Страница 35: ...r and door replace them and apply silicone where envisioned C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Feed box complete emptying and cleaning E Room air fan...
Страница 36: ...the stove is operating at the set power MODULATION the stove is operating at minimum STAND BY Stove off waiting for re ignition due to an external thermostat The stove will only re start when the ext...
Страница 37: ...er NO IGNITION BLACK OUT No current during the ignition phase Take the stove to OFF conditions using key 1 and repeat the procedure described in the Ignition chapter NO PELLETS The pellet feed box is...
Страница 38: ...38 ENGLISH 38...
Страница 39: ...39 ENGLISH 39...
Страница 40: ...o dalzotto com www operastyle it 004276012_MU_IDRO_BASE_575_LCD_009 09 14 The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice i...